background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0150#05 

29.06.2020 

 

3.

 

INSTALLATION 

3.1.

 

Box contents 

 

 

1x complete gas fireplace 

 

1x Touch panel (installed) 

 

1x Remote control (if delivered) 

 

4x AA Batteries  

 

2x AAA Batteries (if remote delivered) 

 

5x bag of decorative stones 

 

1x magnetic gripper 

 

1x 4 metre rubber gas linkage 

 installed (only LPG version) 

 

1x pressure regulator (37mbar) 

 installed (only LPG version) 

 

1x installation and user’s manual

 

 

3.2.

 

Unboxing and installation 

 

The contents of the boxes need to be carefully unwrapped from the foam foil. 

 

Remove the bags with decorative stones from the burner reservoir and place them away from it. 

 

Remove the Styrofoam placed on the unit. 

 

Carefully lift the appliance and pull out the glass shield wrapped in cardboard from the inside of the GaLiO Fire 
Pit Corten. 

 

Check the completeness of the elements with the contents list. 

 

Make sure that the device 

nor its elements weren’t damaged during the transportation (if they were, notify 

the supplier). 

 

Place GaLiO Fire Pit Corten on a flat, paved surface outside of the building, preferably on the place of final 
installation. Leave sufficient space on the side of the appliance where control panel is located (minimum 1 m). 

 

The decorative stones are to be scattered evenly around the reservoir to completely cover the burner of the 
fireplace. 

 

 

WARNING!!!

 

The stones may not cover or be placed inside the device protecting the ignition unit (Photo 1). 

 

 

 

Photo 1 

 
 
 
 
 

Summary of Contents for Galio Fire Pit Black

Page 1: ...nikafires com IG0150 05 29 06 2020 1 INSTALLATION and USER S MANUAL GaLiO Fire Pit Corten G20 G25 Natural Gas G30 G31 Propane Butane Propane H1 H2 D1 D2 mm 320 30 350 950 Manufactured by Planika Sp z o o Bydgoska 38 86 061 Brzoza Poland ...

Page 2: ... 4 3 1 Receiver Błąd Nie zdefiniowano zakładki 4 3 2 Hand held transmitter Błąd Nie zdefiniowano zakładki 4 4 Remote control Błąd Nie zdefiniowano zakładki 4 4 1 Setting Fahrenheit or Celsius Błąd Nie zdefiniowano zakładki 4 4 2 Child Lock Błąd Nie zdefiniowano zakładki 4 4 3 Setting the Time Błąd Nie zdefiniowano zakładki 4 4 4 Switch on the Appliance Igniting the Fire Błąd Nie zdefiniowano zakła...

Page 3: ...om IG0150 05 29 06 2020 3 5 TESTING 22 5 1 Checking for gas leaks 22 5 2 Checking the flame appearance 22 6 MAINTENANCE AND UPKEEP 23 6 1 Testing and cleaning 23 7 TROUBLESHOOTING 24 8 TECHNICAL SPECIFICATION 25 9 MANUFACTURER S CONTACT DETAILS 25 ...

Page 4: ...eds to be placed near the device During the first ignition the GaLiO Fire Pit Corten fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working GaLiO Fire Pit Corten has been designed for decorative purposes The surface of the GaLiO Fi...

Page 5: ...not allow an open flame or any ignited object to reach the gas cylinder The gas cylinder should be in a distance not shorter than 1 5 metres away from the GaLiO Fire Pit Corten fireplace Leaks should be found with the use of a cleaning liquid and water If bubbles form on the surface that means that a there s an existing leak Always use a pressure regulator between the gas bottle and the device Rep...

Page 6: ...lace them away from it Remove the Styrofoam placed on the unit Carefully lift the appliance and pull out the glass shield wrapped in cardboard from the inside of the GaLiO Fire Pit Corten Check the completeness of the elements with the contents list Make sure that the device nor its elements weren t damaged during the transportation if they were notify the supplier Place GaLiO Fire Pit Corten on a...

Page 7: ...device allows to place the gas bottle maximally 3 meters away from the connected control panel however it cannot be placed nearer to the device than 1 5 meters Figure 2 The optional housing for the gas bottle cannot be airtight and has to be correctly ventilated The housing needs to have an upper ventilation slot above the top of the bottle of an area min 1 100 of the area of the base of the housi...

Page 8: ...he device Before connecting the gas supply it is necessary to blow them to remove any remaining metal filings and other contaminants from inside Automatic gas control system should be protected from moisture and dust These factors may cause irreparable damage to the individual components The pipe supplying gas to the fireplace should be equipped with a ball valve with a recommended diameter of 1 2...

Page 9: ... Gas cylinders have two types of connectors Twist on connection The most important thing is the black seal Always check if the seal is present and that it hasn t been damaged during the gas cylinder replacement Some connections have a knob to fasten them in place while others require the use of a wrench Tighten securely left thread Using the tool pay attention not to fasten the connection too tigh...

Page 10: ...witch into the ON position or into the flame image Place the gas bottle in a correct distance from the fireplace min 1 5 metres away WARNING Check the gas connection for leakage If anything suggests a leak is present for instance a characteristic gas smell close the gas bottle valve and under no circumstances turn the device on before removing the leak See point 5 1 After removing the leak one may...

Page 11: ...LACE the tightening cap on an empty or partially full bottle if it s not being used 3 4 3 Regulator replacement LPG version 1 You always need to use a pressure regulator between the gas bottle and the device Replace the pressure regulator every 5 years Allowed pressures 30 mbar 37 mbar recommended 50 mbar Use only the redactors that comply with the EN16129 European Norm 2 Turn off the GaLiO Fire P...

Page 12: ...IG0150 05 29 06 2020 12 6 Take off the linkage from the stub of regulator 7 Attach a new linkage on the stub of regulator 8 Move the clamp into the stub again and tighten it WARNING In the event of visible damage on the clamp replace it for a new one ...

Page 13: ...r The appliance is delivered already configured and ready to work In case of lost or damaged of hand held transmitter the new one has to be programmed and the receiver must first learn the hand held transmitter s signal code before the first use Press the RESET button on the receiver and keep this pressed until 2 beeps are heard Release the RESET button after the second somewhat longer beep Press ...

Page 14: ...liance has been completely switched off NOTE If the appliance is equipped with a 230 VAC connection no batteries are present in the receiver The batteries are placed in two containers 2 batteries in each container located at the bottom of Galio Fire Pit Corten See Figure 5 Photo 5 Receiver batteries containers Unscrew the cover of the first battery container with a wide screwdriver or a coin Photo...

Page 15: ...ic gripper delivered together with the device remove the first battery from the container Photo 7 Removing the first battery using the magnetic gripper To remove the second battery insert the magnetic gripper into the battery container Photo 8 Removing the second battery from the container ...

Page 16: ...16 Place the new batteries into the container WARNING Remember about proper polarization of the batteries Photo 9 Placing the battery in the container Screw the cover of the batteries container Repeat the same procedure for changing the batteries in the second container ...

Page 17: ... 0 C to 55 C The hand held transmitter batteries have a service life of approx one year We recommend you use alkaline batteries Rechargeable batteries are not permitted To replace batteries o Open the cover on the back of the remote control o Remove the batteries from the battery compartment o Place two new 1 5V batteries LR03 or AAA type as indicated in the battery compartment o Close the cover 4...

Page 18: ...me please close the gas supply valve in the gas pipe or valve of the gas cylinder WARNING If the pilot flame goes out for any reason wait for 5 minutes before attempting to re light it WARNING Under conditions of increased humidity rain breeze fog dew etc there may be some temporary problems with switching on the fireplace This is a normal phenomenon associated with the dampening of the ignition e...

Page 19: ...eight To decrease flame high or to set appliance to pilot flame press and hold button To increase flame high press and hold button 4 3 4 Flame height directly to minimum position Pressing the button twice automatically decreases the flames to the LOW position NOTE Flame goes to high fire first before going to low fire Backlight must be on for low fire double click operation ...

Page 20: ...normally when communication is restored Receiver Overheating Powered by mains adapter The valve turns to pilot flame if the receiver temperature is higher than 176 F 80 C If batteries are installed in the receiver in this configuration the temperature must not exceed 60 C Powered by batteries and or connected to the V module The valve turns to pilot position if the temperature in the receiver is h...

Page 21: ...er and cannot be altered in the field 4 4 Touchpad Depending on customers preferences GaLiO Fire Pit Corten Remote may be additionally operated Touch panel Additionally behind Wall Switch the battery box can be placed Photo 10 Touch panel To Turn ON Appliance Press ON OFF button see Photo 10 until two short beeps confirm the start sequence has begun release button Once pilot ignition is confirmed ...

Page 22: ... Check for leaks once again After the inspection dry the inspected connections The device may only be used again after all leaks are removed If the problem happens again please contact the dealer 5 2 Checking the flame appearance Burn the GaLiO Fire Pit Corten on max flame height and check the appearance of the flame The flame should be linear and evenly placed on the whole length of the main burn...

Page 23: ... event of visible damage contact your dealer Igniter gap between igniter and pilot flame should not be bigger than 5 mm Glass screens check for dirt smudges or possible scratches or cracks If cracks are present replace the glass screen for a new one To conduct this contact your dealer Gas linkage and pressure regulator in case their expiry date is invalid replace these ancillaries for new ones If ...

Page 24: ...6 Gas linkage is twisted 7 Pressure regulator link is loose 1 Replace Gas Cylinder 2 Connect the igniter linkage 3 Replace igniter 4 Realign electrode and clear any surrounding debris from area 5 Unmount burner clean the nozzle 6 Straighten the linkage Keep the linkage away from the housing 7 Tighten the link Check for leaks Igniter Not Working 1 Ignitor wire not connected 2 Electrode misaligned o...

Page 25: ...nput pressure mbar 30 37 50 20 Gas flow at 15 C and 1013 mbar m3 h 0 5 Gas flow at 15 C and 1013 mbar kg h 0 35 0 40 0 44 Burner pressure at max flame height mbar 22 2 27 0 35 4 11 0 Nozzle of the main burner mm 1 4 1 4 1 4 1 8 Pilot unit G30 ZP2M L G30 ZP2M L G30 ZP2M L G30 ZP2M L Gas control valve Mertik GV 60 Mertik GV 60 Mertik GV 60 Mertik GV 60 Gas linkage Ø9mm Ø9mm Ø9mm External 9 MANUFACTU...

Reviews: