17
DEVICE HIT
DEVICE TILTED
CO2 LEVEL TOO HIGH
Ventilate the room to reduce the CO
2
level. Wait for
READY
.
WARNING CLOSE THE LID
Do not fill the fuel. Close the fuel inlet lid.
CHECK THE TANK WIRE
CONNECTION
Disconnect the fuel tank wires and connect them again. (FLA 3 XL)
ERROR 01
Fuel spillage has been detected. Turn the device OFF by pressing
and disconnect
the pump. Wipe the visible liquid and wait for min. 1 hour. If the error is not eliminated,
wait for min. 24 hours.
ERROR 05
The device has been moved. Eliminate the source of shock. Wait for
READY
.
ERROR 06/16/17/20
Turn the device OFF
, wait for min. 5 minutes and turn the device ON.
ERROR 15
Turn the device OFF
and level the surface on which the device is installed.
ERROR 21
Turn the device OFF
and ON. Wait for
READY
.
ERROR
02/03/04/10/16/31/32/41/51/61
Contact the Service Department.
FUEL
Use only fuels consisting of
95-96,6%
ethanol by volume. FANOLA
®
is the recommended fuel. Do not use gel, thick and
viscous fuels or fuels of improper electric conductivity. The values must be compliant with those of FANOLA
®
. Other fuels,
such as dehydrated ethanol (i.e. consisting of more than 96,6% by volume ethanol) will cause a device error and loss of the
guarantee.
Fuels consisting of 100% by volume ethanol will damage the device.
CLEANING
–
Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE
–
(keep the provided USB cable for servicing purposes)
We are available on live chat at
BRENNSTOFFNACHFÜLLEN
D
EU
T
SC
H