8
3.4.
Installation of the glass screen
•
Carefully remove cardboard and foam foil from the glass screens.
•
Remove all contaminations from the glass shields which could burn out on the glass during operation of the
FARO (in particular fingerprints).
•
Install glass shields in the corresponding slots on the top of appliance.
Fig 5
–
Installation of the glass in slots
•
Install the metal hood on the top of the all four glass screens
Fig 6
–
Installation of the top
•
Remove the glass shield only in case of damage of the glass.
3.5.
Gas cylinder montage
The gas linkage attached to the device allows to place the gas bottle maximally 1 meter away from the connected
control panel during it replacement. During operation the gas cylinder is hidden inside the device behind easily
removable doors.
Fig 7
–
Gas cylinder installation