/    TEL+886-2-22191816    FAX +886-2-22190655            Page 8 

Note: 

When connecting to the WAN port, use 100-ohm Category 3, 4 or 5 shielded or 

unshielded twisted-pair cable with RJ-45 connectors at both ends for all connections. 

Connecting the Power Adapter 

Plug the power adapter into the power socket on the BLW-03FA, and the other end 
into a power outlet. Check the indicator marked Power on the front panel to be sure it 
is on. If the Power indicator does not light up, refer to Troubleshooting in Appendix 
A. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for BLW-03FA

Page 1: ......

Page 2: ...etting Up TCP IP to Work with BLW 03FA 42 Configuration Computer with Windows 95 98 ME 45 Configuration Computer with Windows 2000 51 Configuration Computer with Windows XP 58 Configuration Computer with Windows NT 65 Configuration Macintosh Computer 72 Verifying Your TCP IP Connectionverview 77 Chapter 6 Printer Server 79 Print Server Installation for Windows 98 ME 79 Print Server Installation fo...

Page 3: ...nefits Internet connection to DSL or cable modem via a 10 100 Mbps WAN port Local network connection via 10 100 Mbps Ethernet ports or 11 Mbps wireless interface supporting up to 128 mobile users 802 11b Compliant interoperable with multiple vendors Provides seamless roaming within 802 11b WLAN environment DHCP for dynamic IP configuration and DNS for domain name mapping Firewall with Stateful Pac...

Page 4: ...or port number the BLW 03FA routes the request to the appropriate server at an internal network IP address This secures your network from direct attack by hackers and provides more flexible management by allowing you to change internal network IP addresses without affecting outside access to your network User Definable Application Sensing Tunnel You may define special applications that require mul...

Page 5: ... local area network using any of the three 10 100 autosensing switch ports These RJ 45 ports auto negotiate the operating speed 10 100 Mbps and the duplex mode half full duplex Access speed to the Internet depends on your service type Full rate symmetric Digital Subscriber Line ADSL provides up to 8 Mbps downstream and 640 Kbps upstream G lite or splitterless ADSL provides up to 1 5 Mbps downstrea...

Page 6: ...A is receiving power WLAN Green On The BLW 03FA has established a valid wireless connection WAN Green On The WAN port has established a valid network connection L LA AN N Link Green On The indicated LAN port has established a valid network connection Activity Amber Flashing The indicated LAN port is transmitting or receiving traffic ...

Page 7: ...ll as a gateway server address and DNS server address from your service provider A computer equipped with a 10 Mbps 100 Mbps or 10 100 Mbps Fast Ethernet card or a USB to Ethernet converter TCP IP protocols installed on each PC that will access the Internet A Java enabled web browser such as Microsoft Internet Explorer 5 0 or above or Netscape Communicator 4 0 or above installed on one PC at your ...

Page 8: ...t Cabling The three LAN ports on the BLW 03FA can auto negotiate the connection speed to 10 Mbps Ethernet or 100 Mbps Fast Ethernet as well as the transmission mode to half duplex or full duplex These LAN ports also support auto configuration for pin signals auto MDI MDI X that allows you to use straight through cable for connecting the BLW 03FA to any network device See Appendix B for details on ...

Page 9: ...W 03FA s location provides optimal reception throughout your home or office Computers equipped with a wireless adapter can communicate with each other as an independent wireless LAN by configuring each computer to the same radio channel However the BLW 03FA can provide access to your wired wireless LAN or to the Internet for all wireless workstations Each wireless PC in this network infrastructure...

Page 10: ...5 shielded or unshielded twisted pair cable with RJ 45 connectors at both ends for all connections Connecting the Power Adapter Plug the power adapter into the power socket on the BLW 03FA and the other end into a power outlet Check the indicator marked Power on the front panel to be sure it is on If the Power indicator does not light up refer to Troubleshooting in Appendix A ...

Page 11: ...irst configure at least one computer as described in Chapter 5 to access the BLW 03FA s web configuration interface See Chapter 4 for information on configuring the BLW 03FA If you have not previously configured TCP IP for your computer refer to Configuring Client TCP IP on page 5 1 All PCs connected to the BLW 03FA must be in the same IP subnet as the BLW 03FA The default IP address of the BLW 03...

Page 12: ...r including Internet Explorer 4 0 or above or Netscape Navigator 4 0 or above Using the web management interface you may configure the BLW 03FA and view statistics to monitor network activity Login To access the BLW 03FA s management interface enter the IP your web browser address of the BLW 03FA in http 192 168 1 1 Note For some browsers it may be necessary to include 88 after the management IP a...

Page 13: ...as been made on a page be sure to click the Apply or Next button at the bottom of the page to enable the new setting Note To ensure proper screen refresh after a command entry be sure that Internet Explorer 5 0 is configured as follows Under the menu Tools Internet Options General Temporary Internet Files Settings the setting for Check for newer versions of stored pages should be Every visit to th...

Page 14: ...roadband connection you have Dynamic IP Address Your ISP may have given you a host name If so enter it into this field Click Finish to complete the setup The Status page will open to allow you to view the connection status as well as other information See Status on page 64 for details PPTP 1 IP Address Enter the ISP assigned to your PC s IP address 2 Subnet Mask Enter the ISP assigned to your PC s...

Page 15: ...to allow you to view the connection status as well as other information See Status on page 64 for details PPP Over Ethernet Enter the PPPoE user name and password assigned by your Service Provider The Service Name is normally optional but may be required by some service providers Leave the Maximum Transmission Unit MTU on the default value 1492 unless you have a particular reason to change it Ente...

Page 16: ...scription INTERNET Displays WAN connection type and status GATEWAY Displays system IP settings as well as DHCP and Firewall status INFORMATION Displays the number of attached clients the firmware versions the physical MAC address for each media interface as well as the hardware version and serial number Security Log Displays illegal attempts to access your network Save Click on this button to save...

Page 17: ...w Click on this button to refresh Dynamic settings TOOLS Use the Tools menu to backup the current configuration restore a previously saved configuration restore factory settings update firmware and reset the BLW 03FA Configuration Tools Choose a function and click RESET Click Apply to reset the BLW 03FA The reset will be complete when the power LED stops blinking ...

Page 18: ...conds all the LEDs will illuminate and the factory settings will be restored Restore Factory Defaults You can click the Reset to Default button to reset the settings of this device to the default values BACKUP RESTORE Backup allows you to save the BLW 03FA s configuration to a file You can then check Restore to restore the saved backup configuration file Restore to factory defaults resets the Bari...

Page 19: ...MWARE UPDATE This tool permits easy downloading of the latest Firmware Download the upgrade file from the PCI website www planex com tw and save it to your hard drive Browse for the file and then click Apply Check the Status page Information section to confirm that the upgrade process was successful ...

Page 20: ...tw TEL 886 2 22191816 FAX 886 2 22190655 Page 18 Basic Setting WAN Specify the WAN connection type provided by your Internet Service Provider then click More Configuration to enter detailed configuration parameters for the selected connection type ...

Page 21: ...n Unit governs the maximum size of the data packets Leave this on the default value 1492 unless you have a particular reason to change it Enter a Maximum Idle Time in minutes to define a maximum period of time for which the Internet connection is maintained during inactivity If the connection is inactive for longer than the Maximum Idle Time it will be dropped Enable the Auto reconnect option to a...

Page 22: ... your ISP If your ISP used the MAC address of an Ethernet card as an identifier when first setting up your broadband account connect only the PC with the registered MAC address to the BLW 03FA and click the Clone MAC Address button This will replace the current BLW 03FA MAC address with the already registered Ethernet card MAC address If you are unsure of which PC was originally set up by the broa...

Page 23: ... IP Address Setting If your Internet Service Provider has assigned a fixed IP address enter the assigned address and subnet mask for the Wireless Barricade then enter the gateway address of your ISP You may need a fixed address if you want to provide Internet services such as a web server or FTP server ...

Page 24: ...eans there is no time limit on the IP address lease IP Address Pool A dynamic IP start address may be specified by the user e g 192 168 1 100 default value Once this start IP address has been assigned IP addresses running from 192 168 1 100 to 192 168 1 199 will be part of the dynamic IP address pool IP addresses from 192 168 1 2 to 192 168 1 99 and 192 168 1 200 to 192 168 1 254 will be available...

Page 25: ...D The Service Set ID This should be set to the same value as other wireless devices in your network Note The SSID is case sensitive and can consist of up to 32 alphanumeric characters Transmission Rate Set the data rate transmitted from the BLW 03FA The lower the data rate the longer the transmission distance Default Fully Automatic Basic Rate Select All 1 2 5 5 11Mbps from the drop down list to o...

Page 26: ...or the more robust 128 bit encryption keys You can automatically generate encryption keys or you can manually enter the keys For automatic 64 bit security you enter a passphrase that is used to create four keys as shown below The automatic 128 bit security generates a single key by entering a passphrase If you use encryption configure the same keys used for the BLW 03FA on each of your wireless cl...

Page 27: ...posing the BLW 03FA to the Internet Passwords can contain from 3 12 alphanumeric characters and are not case sensitive If your password is lost or you cannot gain access to the user interface press the Reset button on the rear panel holding it down for at least five seconds to restore the factory defaults default is 0000 Time Zone Sets the time zone for the BLW 03FA This information is used for lo...

Page 28: ...22190655 Page 26 Advanced Setting Address Mapping Allows one or more public IP addresses to be shared by multiple internal users Enter the Public IP address you wish to share into the Global IP field Enter a range of internal IPs that will share the global IP into the from field ...

Page 29: ... virtual server remote users accessing services Special Application Some applications require multiple connections like Internet games Video conferencing and Internet telephony and so on Due to the firewall function these applications can not work with pure NAT router Special Applications makes some of these applications to work with NAT router ...

Page 30: ...PLANEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 28 ...

Page 31: ...16 FAX 886 2 22190655 Page 29 DDNS Dynamic DNS support enables users to enjoy domain name even they have no fixed IP address The proposed system supports the following DDNS providers WWW DYNDNS ORG WWW TZO COM All other DDNS providers that support CGI update commands ...

Page 32: ...haracteristics The community concept is a local one defined at the agent The agent establishes one community for each desired combination of authentication access control and proxy characteristics Each community is given a unique within this agent community name and the management stations within that community are provided with and must employ the community name in all get operations The agent ma...

Page 33: ...of SNMP an unsolicited message can be sent by an agent to management station The purpose is to notify the management station of some unusual event Routing Static Route 1 Click Add button 2 Type the destination s IP address the net mask the Gateway IP and Metric 3 Click OK button to finish configuration Routing Table ...

Page 34: ...ll submenus The BLW 03FA s firewall can provide the access control of connected client PCs block common hacker attacks including IP Spoofing Land Attack Ping of Death IP with zero length Smurf Attack UDP port loopback Snork Attack TCP null scan and TCP SYN flooding The firewall does not significantly affect system performance so we advise leaving it enabled to protect your network users Note When ...

Page 35: ...cluded in the Access Control screen Field Description Normal Filtering Table Displays the IP address and filtering status of the connected client PC MAC Filtering Table Displays the MAC address of the client PC Remote Management Allows you to set the IP address of an administrator for a remote management Note Click on Add PC and define the appropriate settings for client PC services as shown in th...

Page 36: ...PLANEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 34 ...

Page 37: ...ocking Using the above screen to block access to the Web sites specified in the table Schedule Rule You can filter Internet access for local clients based on the Rule Name and time of day 1 Click on Add Schedule Rule 2 Define the appropriate settings for a schedule rule as shown in the following screen ...

Page 38: ...PLANEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 36 3 Click OK and then the APPLY button to save your settings as shown on previous page ...

Page 39: ...ket Inspection SPI allows full support of different application types that are using dynamic port numbers For the applications checked in the list below the Systems will support full operation as initiated from the local LAN The Systems firewall can block common hacker attacks including IP Spoofing Land Attack Ping of Death IP with zero length Smurf Attack UDP port loopback Snork Attack TCP null s...

Page 40: ...two way Internet access Enter the IP address of a DMZ host to this screen Adding a client to the DMZ Demilitarized Zone may expose your local network to a variety of security risks so only use this option as a last resort MISC Allows a remote PC to configure manage and monitor the BLW 03FA using a standard web browser Check Enable and enter the IP address of the remote host Click APPLY Note If you...

Page 41: ...FAX 886 2 22190655 Page 39 Chapter 5 Configuring Client TCP IP Installing TCP IP Windows 95 98 ME 1 Click Start Settings Control Panel 2 Double click the Network icon and select the Configuration tab in the Network window 3 Click the Add button 4 Double click Protocol 5 ...

Page 42: ...allation procedure and restart your PC to enable the TCP IP protocols The operating system may prompt you to restart your system Click Yes and the computer will shut down and restart Windows 2000 1 Click the Start button and choose Settings then click Control Panel 2 Double click the Network and Dial up Connections icon then Local Area Connection icon and press the Properties button in the General...

Page 43: ...PLANEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 41 ...

Page 44: ...to return to the Network window 6 The TCP IP protocol will be listed in the Network window Click OK to complete the install procedure Setting Up TCP IP to Work with BLW 03FA Windows 95 98 ME 1 Click Start Settings Control Panel 2 Double click the Network icon Highlight the TCP IP line that has been assigned to your network card on the Configuration tab of the Network window ...

Page 45: ...uirements Note that the default IP address of the BLW 03FA is 192 168 1 1 Windows 2000 1 Click the Start button and choose Settings then click Control Panel 2 Double click the Network and Dial up Connections icon then Local Area Connection icon and press the Properties button in the General tab 3 Select the TCP IP line that has been assigned to your network card in the Local Area Connection Proper...

Page 46: ...t IP address of the BLW 03FA is 192 168 1 1 Windows XP 1 Click the start button and choose Control Panel 2 Select the Network and Internet Connections icon then click the Network Connections icon and double click on the LAN or High Speed Internet 3 Press the Properties button in the General tab 4 Select the TCP IP line that has been assigned to your network card in the Local Area Connection Proper...

Page 47: ...ttings After you have completed the hardware setup by connecting your devices you need to configure the computer to connect to the BLW 03FA You need to determine how your ISP issues your IP address Many ISPs issue these numbers automatically using a networking technology known as Dynamic Host Control Protocol or DHCP Other ISPs will specify your IP address and associated numbers which you must ent...

Page 48: ...MMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 46 2 Double click the Network icon 3 On the Network window Configuration tab double click the TCP IP entry for your network card ...

Page 49: ...ddress automatically is already checked your computer is already configured for DHCP Click Cancel to close each window and skip to Step 2 Disable HTTP Proxy on page 5 12 5 Make a note of the current IP Address and Subnet Mask a space is provided on the next page 6 Click the Gateway tab and record the numbers listed under Installed gateways ...

Page 50: ...k Yes and the computer will shut down and restart TCP IP Configuration Setting IP Address ____ ____ ____ ____ Subnet Mask ____ ____ ____ ____ Primary DNS Server ____ ____ ____ ____ Secondary DNS Server ____ ____ ____ ____ Default Gateway ____ ____ ____ ____ Step 2 Disable the HTTP Proxy You will need to verify that the HTTP Proxy feature of your web browser is disabled This is so that your web bro...

Page 51: ...ONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 49 1 Open Internet Explorer Click Tools Internet Options 2 In the Internet Options window click the Connections tab Click the LAN Settings button ...

Page 52: ...y double click Advanced then click Proxies Check Direct connection to the Internet Click OK 3 Repeat these steps for each Windows 95 98 ME computer connected to your BLW 03FA Step 3 Obtain IP Settings from Your BLW 03FA Now that you have configured your computer to connect to your Wireless Barricade it needs to obtain new network settings By releasing old IP settings and renewing them with setting...

Page 53: ...nctioning Click OK to close the IP Configuration window Configuration Computer with Windows 2000 Step 1 Configure TCP IP Settings After you have completed the hardware setup by connecting your devices you need to configure the computer to connect to the BLW 03FA You need to determine how your ISP issues your IP address Many ISPs issue these numbers automatically using a networking technology known...

Page 54: ...PLANEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 52 1 From the Windows desktop click Start Settings Control Panel ...

Page 55: ...MMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 53 2 Double click the Network icon 3 On the Network window Configuration tab double click the TCP IP entry for your network card ...

Page 56: ...ddress automatically is already checked your computer is already configured for DHCP Click Cancel to close each window and skip to Step 2 Disable HTTP Proxy on page 5 12 5 Make a note of the current IP Address and Subnet Mask a space is provided on the next page 6 Click the Gateway tab and record the numbers listed under Installed gateways ...

Page 57: ...k Yes and the computer will shut down and restart TCP IP Configuration Setting IP Address ____ ____ ____ ____ Subnet Mask ____ ____ ____ ____ Primary DNS Server ____ ____ ____ ____ Secondary DNS Server ____ ____ ____ ____ Default Gateway ____ ____ ____ ____ Step 2 Disable the HTTP Proxy You will need to verify that the HTTP Proxy feature of your web browser is disabled This is so that your web bro...

Page 58: ...ONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 56 1 Open Internet Explorer Click Tools Internet Options 2 In the Internet Options window click the Connections tab Click the LAN Settings button ...

Page 59: ...y double click Advanced then click Proxies Check Direct connection to the Internet Click OK 3 Repeat these steps for each Windows 95 98 ME computer connected to your BLW 03FA Step 3 Obtain IP Settings from Your BLW 03FA Now that you have configured your computer to connect to your Wireless Barricade it needs to obtain new network settings By releasing old IP settings and renewing them with setting...

Page 60: ...FA is functioning Click OK to close the IP Configuration window Configuration Computer with Windows XP Step 1 Configure TCP IP Settings After you have completed the hardware setup you need to configure your computer to connect to your BLW 03FA You also need to determine how your ISP issues your IP address Many ISPs issue these numbers automatically using a networking technology known as Dynamic Ho...

Page 61: ...PLANEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 59 Here is what to do 1 From the Windows desktop click the start button Choose Control Panel ...

Page 62: ...http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 60 2 Select the Network and Internet Connections icon then click the Network Connections icon 3 Double click on the LAN or High Speed Internet 4 Click Properties ...

Page 63: ...hat you need to record is on the Internet Protocol TCP IP Properties dialog box Use the spaces below to record the information If Obtain an IP address automatically and Obtain DNS server address automatically are already selected your computer is already configured for DHCP Click Cancel to close each window and skip to Step 2 Disable HTTP Proxy on page 5 25 ...

Page 64: ...NS Server ____ ____ ____ ____ Secondary DNS Server ____ ____ ____ ____ Default Gateway ____ ____ ____ ____ Step 2 Disable the HTTP Proxy You will need to verify that the HTTP Proxy feature of your Web browser is disabled This is so that your Web browser will be able to view the configuration pages inside your BLW 03FA The following steps are for Internet Explorer and for Netscape Determine which b...

Page 65: ...om tw TEL 886 2 22191816 FAX 886 2 22190655 Page 63 2 In the Internet Options window click the Connections tab Next click the LAN Settings button 3 Clear all the checkboxes 4 Click OK and then click OK again to close the Internet Options Windows ...

Page 66: ... configured your computer to connect to your BLW 03FA it needs to obtain new network settings By releasing any old IP settings and renewing them with settings from your BLW 03FA you will also verify that you have configured your computer correctly 1 From the Windows desktop click the Start button then Programs then Accessories and then click Command Prompt ...

Page 67: ...TER to close the Command Prompt window Configuration Computer with Windows NT Step 1 Configure TCP IP Settings After you have completed the hardware setup you need to configure your computer to connect to your BLW 03FA You need to determine how your ISP issues your IP address Many ISPs issue these numbers automatically using a networking technology known as Dynamic Host Configuration Protocol or D...

Page 68: ...NEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 66 Here is what to do 1 From the Windows desktop click Start Settings Control Panel 2 Double click the Network icon ...

Page 69: ...tp www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 67 3 Click on the Protocols tab 4 Double click TCP IP Protocol 5 Click on the IP Address tab 6 In the Adapter dropdown list be sure your Ethernet adapter is selected ...

Page 70: ...space provided below 8 Click the DNS tab to see the primary and secondary DNS servers Record these values in the appropriate spaces below 9 After writing down your IP settings click the IP address tab Check Obtain IP address automatically and click OK Click OK again to close the Network window 10 Windows may copy files and will then prompt you to restart your system Click Yes and your computer wil...

Page 71: ... browser is disabled This is so that your web browser will be able to view the BLW 03FA configuration pages The following steps are for Internet Explorer and for Netscape Determine which browser you use and follow the appropriate steps Internet Explorer 1 Open Internet Explorer Click Tools Internet Options 2 In the Internet Options window click the Connections tab Next click LAN Settings ...

Page 72: ...2 In the Preferences window under Category double click Advanced then click Proxies Check Direct connection to the Internet Click OK Step 3 Obtain IP Settings From Your BLW 03FA Now that you have configured your computer to connect to your BLW 03FA it needs to obtain new network settings By releasing old IP settings and renewing them with settings from the BLW 03FA you will also verify that you ha...

Page 73: ...COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 71 desktop click Start Programs Command Prompt 2 In the Command Prompt window type IPCONFIG RELEASE and press the ENTER key ...

Page 74: ...is because these steps and screenshots were created using Mac OS 8 5 Mac OS 7 x and above are all very similar but may not be identical to Mac OS 8 5 Step 1 Configure TCP IP Settings After you have completed the hardware setup you need to configure your computer to connect to the BLW 03FA You need to determine how your ISP issues your IP address Many ISPs issue these numbers automatically using a ...

Page 75: ...w planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 73 Here is what to do 1 Pull down the Apple Menu Click Control Panels and select TCP IP 2 In the TCP IP dialog box make sure that Ethernet is selected in the Connect Via field ...

Page 76: ...tings select Using DHCP Server in the Configure field and close the window 5 Another box will appear asking whether you want to save your TCP IP settings Click Save TCP IP Configuration Setting IP Address ____ ____ ____ ____ Subnet Mask ____ ____ ____ ____ Router ____ ____ ____ ____ Name Server ____ ____ ____ ____ Step 2 Disable the HTTP Proxy You will need to verify that the HTTP Proxy feature of...

Page 77: ...lanex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 75 Internet Explorer 1 Open Internet Explorer Click Edit Preferences 2 In the Internet Explorer Preferences window under Network select Proxies 3 Uncheck all checkboxes and click OK ...

Page 78: ... the Advanced category select Proxies 3 Select Direct Connection to the Internet and click OK Step 3 Obtain IP Settings From Your BLW 03FA Now that you have configured your computer to connect to your BLW 03FA it needs to obtain new network settings By releasing old IP settings and renewing them with settings from the BLW 03FA you will also verify that you have configured your computer correctly ...

Page 79: ...5 0 and your Default Gateway is 192 168 1 1 These values confirm that your BLW 03FA is functioning 3 Close the TCP IP window Verifying Your TCP IP Connectionverview After installing the TCP IP communication protocols and configuring an IP address in the same network as the BLW 03FA use the Ping command to check if your computer has successfully connected to the BLW 03FA The following example shows...

Page 80: ...32 bytes of data Request timed out there may be something wrong in your installation procedure Check the following items in sequence 1 Is the Ethernet cable correctly connected between the BLW 03FA and the computer The LAN LED on the BLW 03FA and the Link LED of the network card on your computer must be on 2 Is TCP IP properly configured on your computer If the IP address of the BLW 03FA is 192 16...

Page 81: ...er 2 Restart you computer 3 Open your Printers folder and start the Add Printer Wizard 4 When prompted select Local Printer 5 On the Select the Printer Port screen select monitor and Click Next to continue 6 Select the correct Printer Manufacturer and Model or use the Have Disk option if appropriate 7 Installation is now complete You can now print using this printer Print Server Installation for W...

Page 82: ...e select the Standard TCP IP Port Click Next and Next 5 The Add Standard TCP IP Printer Port Wizard box will then appear as shown below Type the IP address assigned to the print server in the Printer Name or IP Address box click Next 6 In the Add Standard TCP IP Printer Port Wizard box shown in the following picture Select Custom Click Settings button and click Next ...

Page 83: ...www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 81 7 In the Configure Standard TCP IP Port Monitor box shown in the following picture select LPR form Protocol and type in a queue name for example lp1 8 Click OK and Next ...

Page 84: ...t button 12 A box containing the message To confirm that the printer is installed properly you can print a test page will appear Select Yes Recommended and click Finish 13 The installation is complete Printer Compatible list Compatible Device Test Test OS Win98 Win2000 Printer Tested NO Vendor Model Result Remark 01 Epson EPSON Stylus Color 300 Pass 02 Epson EPSON Stylus Color 400 Pass 03 Epson EP...

Page 85: ...Stylus Photo 790 Pass 14 Epson EPSON IP 100 Pass 15 HP HP DeskJet 610C Pass 16 HP HP DeskJet 640C Pass 17 HP HP DeskJet 710C Pass 18 HP HP LaserJet 6L Pass 19 HP HP LaserJet 1100 Pass 20 HP HP LaserJet 4050 Pass Different OS Print test paper List Printer Type OS1 OS2 OS3 OS4 OS5 OS6 OS7 OS8 OS9 Result Epson photo 790 3 3 3 3 3 3 3 3 3 Pass Epson photo 750 3 3 3 3 3 3 3 3 3 Pass HP LaserJet 6L 3 3 ...

Page 86: ...Troubleshooting Chart Symptom Action LED Indicators Power LED is OFF External power supply has failed or is disconnected Check connections between the BLW 03FA the external power supply and the wall outlet If the power indicator does not light when the power cord is plugged in you may have a problem with the power outlet power cord or external power supply If the unit powers off after running for ...

Page 87: ... the adapter on the attached device and cable connections for possible defects Replace any defective adapter or cable if necessary Network Connection Problems Cannot Ping the BLW 03FA from the attached LAN or the BLW 03FA cannot Ping any device on the attached LAN Verify that the IP addresses are properly configured For most applications you should use the BLW 03FA s DHCP function to dynamically a...

Page 88: ...eway Check that you have a valid network connection to the BLW 03FA and that the port you are using has not been disabled Check the network cabling between the management station and the BLW 03FA Forgot or lost the password Press the Reset button on the front panel holding it down for at least five seconds to restore the factory defaults Printer Server The printer cannot print or prints garbage Ma...

Page 89: ...ors that conform with FCC standards For 10BASE T 100BASE TX connections a twisted pair cable must have two pairs of wires Each wire pair is identified by different colors For example one wire might be red and the other red with white stripes Also an RJ 45 connector must be attached to both ends of the cable Cables Figure B 1 illustrates how the pins on the RJ 45 connector are numbered Be sure to h...

Page 90: ... TD 3 RD 2 TD 6 RD 3 RD 1 TD 6 RD 2 TD Pins 4 5 7 and 8 are not connected RJ 45 Port Pin Assignments Pin MDI Signal Name MDI X Signal Name 1 Transmit Data TD Receive Data RD 2 Transmit Data TD Receive Data RD 3 Receive Data RD Transmit Data TD 6 Receive Data RD Transmit Data RD Pins 4 5 7 and 8 are not connected z The and signs represent the polarity of the wires that make up each wire pair ...

Page 91: ...lec Wireless RF z Radio Complies with IEEE 802 11b z Frequency Band USA FCC 2412 2462MHz Ch1 Ch11 Canada IC 2412 2462MHz Ch1 Ch11 Europe ETSI 2412 2472MHz Ch1 Ch13 Spain 2457 2462MHz Ch10 Ch11 France 2457 2472MHz Ch10 Ch13 Japan STD T66 STD 33 2412 2484MHz Ch1 Ch14 z Operating Channels IEEE 802 11 compliant z Channels 14 channels Japan z Modulation Type BPSK for 1Mbps QPSK for 2Mbps CCK for 5 5 11...

Page 92: ...ANEX COMMUNICATIONS INC http www planex com tw TEL 886 2 22191816 FAX 886 2 22190655 Page 90 Receive sensitivity 80dBm for 11Mbps 8 BER 1E 5 83dBm for 5 5Mbps 8 BER 1E 5 88dBm for 2Mbps 8 BER 1E 5 90dBm f ...

Reviews: