background image

USER MANUAL 

Model Z64 

 
Congratulations on purchasing this excellent multifunction home/office alarm security system. This system has a 

clearly written English User Manual providing step by step instruction for set up.   

 

 

 

 

 

STEP 1

 

Preparation of Sensors for Installation

 

 

 

Motion Detectors. 

 

A. turn 

ON/OFF 

switch to 

OFF 

position  

B. open motion detector and install battery   

C. maintain 

ON/OFF 

switch in 

OFF 

position  

 

 

Window/Door Sensor. 

 

A. separate sensor from magnetic bar   

B. opens the sensor and installs battery   

C. keeps sensor and bar separate   

 

 

Smoking Detector. 

 

Install battery   

 

Summary of Contents for Z64

Page 1: ...step by step instruction for set up STEP 1 Preparation of Sensors for Installation Motion Detectors A turn ON OFF switch to OFF position B open motion detector and install battery C maintain ON OFF switch in OFF position Window Door Sensor A separate sensor from magnetic bar B opens the sensor and installs battery C keeps sensor and bar separate Smoking Detector Install battery ...

Page 2: ...our telephone into the TEL jack of the keypad dialer Notice A phone line inserted into the wrong dialer phone jack may prevent the accessibility of the keypad dialer from a remote location by telephone Powering up This keypad controller has a security enhancing design which locates the on off switch on the top of the keypad dialer unit push down on the blue on off button with a pencil point A Plug...

Page 3: ...f cover which will produce pulsating light in red LED case Hold button until light is steady on Turn keypad power switch on Depress and hold black siren button again Pulsating light in red LED reappears Depress the keypad PANIC button Pulsating siren light will steady and go off release black button four red lights will come on Registration complete Turn keypad power switch off STEP 2 Each compone...

Page 4: ...digit numbers to each sensor Window door sensors may be assigned any number between 09 and 64 notice must 2 digits motion detectors smoke gas detectors any number between 01 and 09 notice must 2 digits These are zone numbers You may use the same assigned zone for up to 99 sensors When a sensor is triggered the assigned zone number will light up on the LED screen of the keypad It may be helpful for...

Page 5: ...ed using this procedure Study 09 to 63 trigger Enter the number for selected this sensor from 09 63 must 2 digits Trigger wireless range bean motion detector bean motion detector Plug in power supply of wireless range bean motion detector receiver 6 Activating the Motion Detector For each motion detector you use choose a number from 01 to 08 notice must 2 digits with your system in programming sta...

Page 6: ...e face of the gas detector You will hear a double beep sound to indicate that it has been activated C To trigger the glass break detector knock your glass window with any metal Until you hear a double beep sound from your wireless keypad controller to indicate that it has been activated Each smoke gas detector glass break detector has to be individually activated using this procedure Study 01 to 0...

Page 7: ...r the number sequence below and where the 00 to 30 appears enter the delay time you wish up to 30 minutes The default factory setting for delay time is one minute 5 5 00 to 30 Enter minutes in two digits 00 means no delay 01 means 1 minute delay 30 means 30 minute delay 10 Setting the Entrance Delay Time Disarm Delay Model This function allows you time to enter your premises when your alarm system...

Page 8: ...5 4 00 to 30 Enter minutes in two digits 00 means silent alarm 01 means 1 minutes sound 30 means 30 minutes sounds 12 Programming Stored Phone Numbers To program your dialer with the phone numbers you want called when the alarm is triggered up to six numbers enter the number sequence below into your keypad In place of the enter phone number enter the phone number If your calling location requires ...

Page 9: ...t or disconnected this function must be turn on to be operational With your system in programming status enter the number sequence below into the keypad In place of the 0 or 1 press 1 to turn on this function or 0 to turn off this function The default factory setting is 1 ON When this function is activated and the alarm system is armed line interruption is signaled by three siren blasts at ten sec...

Page 10: ...he phone receiver to listen Listen to your message through phone receiver 16 Remote Access to Keypad Dialer You may change your dialer function settings arm disarm monitor remotely by phone The number of times the phone rings before you are connected with the Dialer System can be preset by entering the number sequence below into your keypad In place of the 00 to 12 enter the number of rings from o...

Page 11: ...ed Phone Number 5 2 0000 to 9999 Professional CONTACT ID code must be 4 numbers 18 Exit Programming Status When you have completed programming the system s functions push the button Exit on the keypad after 30 second system will automatically exit programming status 18 Resetting Your System Functions Reset your system to the factory default setting The factory default password is 1234 turn off pow...

Page 12: ...ps by entering the number of the function you want to activate To arm system press number 1 To disarm system press number 2 To monitor your home press this allows 30 seconds of listening time press for an additional 30 seconds To exit press 4 What to do When the Alarm Auto Dialer call you When you receive the recorded message from your alarm system you have three options Press This allows you to m...

Page 13: ...ctory password is 1234 12 1 12 To HOME ARM the alarm system Press the follow button below on wireless portable keypad Password factory password is 1234 12 2 12 To DISARM the alarm system Press the follow button below on wireless portable keypad Password factory password is 1234 12 3 12 For Emergency Press the follow button below on wireless portable keypad Password factory password is 1234 12 11 R...