8

9

100 LED (Ethernet)

The  RJ-45  port  has  a  100  LED.  Steady  green  indicates  that  the  port  is  operating  at 
100Mbps. If the LED is off, the link speed is 10Mbps.

LNK/ACT LED (Ethernet)

The RJ-45 port has a LNK/ACT LED. Steady green indicates that the port has good linkage 
to its associated device. Flashing green indicates that the port is receiving or transmitting 
data from/to its associated partner. 

If the port is connected but the LNK/ACT LED is dark, check the following items:

1.  The converter and the connected device’s power are on or not.

2.  The port’s cable is firmly seated in its connectors in the switch and in the as-

sociated device.

3.  The connecting cable is good and with correct type.

4.  The connecting device, including any network adapter is functional.

FDX/COL LED (Ethernet)

A collision occurs when two stations within a collision domain attempt to transmit data at 
the same time. Intermittent flashing amber of the collision LED is normal; the contending 
adapters resolve each collision by means of a wait-then-retransmit algorithm. Frequency 
of collisions is an indicator of heavy traffic on the network.

If the FDX/COL lights amber which means the port is under full-duplex operation or dark 
for half-duplex mode. 

LNK LED (VDSL)

If both ends of the VDSL devices are connected then the LED will blink for a while (in 10 
seconds), this is the stage of speed auto-negotiation. After the negotiation process, the 
LNK LED will stay green. If the LED blinks always, that means the link process is fail.

ACT LED (VDSL)

If there is any traffic transverses the port then the LED will light green. Otherwise, off 
means no traffic on the network.

2.1.2 MODE DIP Switch (VC-102M only)

The  converter  provides  5  selective  transmission  modes  that  defined  by  predetermined 
profiles. By switching the transmission modes, you can obtain a best transmission mode 
to suit with phone line quality or distance of connectivity. The following is the summary 
table  of  transmission  modes,  bandwidth  and  distance  extensibility  tested  for  AWG  24 
(0.5mm) twisted-pair without noise and cross talk.

Profile 
Name

Profile 
Type

Downstream 
Rate (Mbps)

Upstream Rate 
(Mbps)

Maximum Distance between 
the Master  and Slave device

ANSI

Public

15.17

4.27

4100 feet (1.25km)

ETSI

Public

11.38

4.27

4100 feet (1.25km)

Summary of Contents for VC-102M

Page 1: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruc tion manual may cause harmful interference to radio communications how ever there is...

Page 2: ...SL Converter 1 1 3 Key Features 3 1 4 Specifications 4 Chapter 2 Hardware Description 7 2 1 Front Panel and Real Panel 7 2 2 The Rear Panel 9 Chapter 3 Installing and Using VDSL Converter 11 3 1 Insta...

Page 3: ...one line network because every room or house could use the existing phone line to transmit data to the Internet and the whole building could share the Internet line to the wide area network with minim...

Page 4: ...n 10BASE T Category 3 4 or 5 UTP n 100BASE TX Category 5 UTP n Ethernet over VDSL Twisted pair telephone wires The two drawings listed below are typical application for the Ethernet over VDSL converte...

Page 5: ...mission modes through DIP switch on VC 102M or manage ment interface of VC 1602 QAM Quadrature Amplitude Modulation line code Designed based on Frequency Division Duplex Half duplex Back pressure and...

Page 6: ...VE 10 11 11Mbps symmetrical rate up to 4100 feet 1 25km VE 15 15 17Mbps asymmetrical rate up to 3500 feet 1 05km Cables 10Base T 2 pair UTP Cat 3 4 5 up to 100m 328ft 100Base TX 2 pair UTP Cat 5 up to...

Page 7: ...5 Standard Compli ance IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE802 3x Full Duplex PAUSE frame flow controlEthernet over VDSL...

Page 8: ...6...

Page 9: ...n this chapter display the unit LED indicators Before connecting any network device to the converter read this chapter carefully 2 1 Front Panel and Real Panel The units front panel provides a simple...

Page 10: ...gorithm Frequency of collisions is an indicator of heavy traffic on the network If the FDX COL lights amber which means the port is under full duplex operation or dark for half duplex mode LNK LED VDS...

Page 11: ...erter before making any transmission mode adjustment Transmission mode DIP switch ANSI ON 1 2 3 4 ETSI ON 1 2 3 4 VE 5 ON 1 2 3 4 VE 10 Default ON 1 2 3 4 VE 15 ON 1 2 3 4 2 2 The Rear Panel The rear...

Page 12: ...ve all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device...

Page 13: ...e normal telephone line it could setup an up to 15 17Mbps asymmetric backbone but one converter must be Master VC 102M and the other one is Slave VC 102S NOTE VC 102M can be connected PLANET s previou...

Page 14: ...a standalone PC 1 Power on the VC 102M S by connecting its power source 2 Power LED will illuminate 3 Connect VDSL line from another VDSL device to VDSL port of the VC 102M S 4 LNK LED will illuminate...

Page 15: ...13 5 Connect telephone to the POTS port 6 Connect Ethernet port to Ethernet device via regular Cat 5 cable NOTE Please refer to your Ethernet device User s Manual for the device s set up information...

Page 16: ...itch or VC 102M to other speed mode 2 Please note you must use 1 VC 102M and 1 VC 102S connect to each other to make it work SYMPTOM Switch LNK ACT LED does not lit after cable is connected to the por...

Page 17: ...15...

Page 18: ...Part No EM VC102...

Reviews: