6
IGS-4215-4T2S
Max. Fault Alarm Loading: 24V, 1A
DC Input: 9-48V , 1A max.
AC Input: 24V , 0.6A max.
V1+
V2+
PWR1
PWR2
Alarm
1 2 3 4 5 6
Figure 3-3:
IGS-4215-4T2S Inlet Power Socket
2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
1
2
3
4
5
6
V1+ V1-
V2+ V2-
Power 1
Power 2
Note
The wire gauge for the terminal block should be in the
range from
12
to
24 AWG
.
Note
1.
The power input range is
DC 12~48V
for IGS-
4215-16T2S,
DC 9~48V
for IGS-4215-8T2S and IGS-
4215-4T2S.
2. Use
one power input
when using
AC 24V
.
Caution
PWR1 and PWR2 must provide the
same DC voltage
while operating with dual power input.