4.3  Storing Current Switch Configuration

At  the 

“IGS-4215-16T2S #”

  prompt,  enter 

“copy  running-config 

startup-config” 

as shown in Figure 4-4.

Figure 4-4: 

 Saving Current Configuration Command Screen

Note

If  you  are  not  familiar  with  console  command  or  the 
related  parameter,  enter 

“?”

 anytime in console to get 

the help description.

Summary of Contents for IGS-4215-16T2S

Page 1: ...Industrial 4 8 16 Port 10 100 1000T 2 Port 100 1000X SFP Managed Gigabit Ethernet Switch IGS 4215 series Quick Installation Guide...

Page 2: ...the Console 8 4 2 Configuring IP Address via the Console 9 4 3 Storing Current Switch Configuration 11 4 4 SSH Login IGS 4215 8T2S and IGS 4215 4T2S 12 5 Starting Web Management 13 5 1 Logging in to...

Page 3: ...rial Managed Switch mentioned in this Quick Installation Guide refers to the IGS 4215 series Open the box of the Industrial Managed Switch and carefully unpack it The box should contain the following...

Page 4: ...to RS232 converter The above Workstations have been installed with terminal emulator such as Hyper Terminal included in Windows XP 2003 putty or tera term Serial cable one end is attached to the RS23...

Page 5: ...ire 1 Insert positive negative DC power wires into contacts 1 and 2 for Power 1 or 5 and 6 for Power 2 IGS 4215 16T2S Fault V1 V2 PWR2 PWR1 Max fault loading 24V 1A DC Input 12 48V 1 5A max AC Input 2...

Page 6: ...or preventing the wires from loos ening 1 2 3 4 5 6 V1 V1 V2 V2 Power 1 Power 2 Note The wire gauge for the terminal block should be in the range from 12 to 24 AWG Note 1 The power input range is DC 1...

Page 7: ...Terminal Emulation Software Serial Port RS232 to RJ45 Cable Console Port RJ45 Figure 4 1 Industrial Managed Switch Console Connectivity A terminal program is required to make the software connection t...

Page 8: ...ault user name and password are shown in Figure 4 1 below Username admin Password admin Figure 4 1 Industrial Managed Switch Console Login Screen The user can now enter commands to manage the Industri...

Page 9: ...t Mask 255 255 255 0 To check the current IP address or modify a new IP address for the Industrial Managed Switch please use the procedures as follows Display of current IP address 1 At the IGS 4215 1...

Page 10: ...teway 192 168 1 254 The previous command would apply the following settings for the Industrial Managed Switch IP Address 192 168 1 100 Subnet Mask 255 255 255 0 Gateway 192 168 1 254 Figure 4 3 Config...

Page 11: ...16T2S prompt enter copy running config startup config as shown in Figure 4 4 Figure 4 4 Saving Current Configuration Command Screen Note If you are not familiar with console command or the related par...

Page 12: ...name and password for remote login when using telnet please use admin for both username and password Default IP address 192 168 0 100 Username admin Password admin Figure 4 5 Industrial Managed Switch...

Page 13: ...he manager PC must be set to the same IP subnet address For example the default IP address of the Industrial Managed Switch is 192 168 0 100 then the manager PC should be set to 192 168 0 x where x is...

Page 14: ...the following dialog box appears please enter the default user name and password admin The login screen in Figure 5 2 appears Default IP Address 192 168 0 100 Default Username admin Default Password a...

Page 15: ...eb page lets you access all the commands and statistics the Industrial Managed Switch provides Figure 5 4 Switch Menu Now you can use the Web management interface to continue the Switch management Ple...

Page 16: ...onfiguration as a startup configuration the startup configuration file will be loaded automatically across a system reboot 1 Click Save Save Configurations to FLASH to log in to the Configuration Mana...

Page 17: ...e press the hardware reset button on the front panel for about 10 seconds After the device is rebooted you can log in the management Web interface within the same subnet of 192 168 0 xx IGS 4215 16T2S...

Page 18: ...18 IGS 4215 4T2S P1 P2 Alarm Ring Reset 1000 LNK ACT 100 LNK ACT R O 6 5 ACT LNK 10 100 ACT LNK 1000 Reset Button Figure 6 1 Reset Button...

Page 19: ...w planet com tw en support faq Switch support team mail address support planet com tw IGS 4215 Series User s Manual https www planet com tw en support download php method keyword keyword IGS 4215 view...

Page 20: ......

Reviews: