The following is the summary table of Reset button functions
:
Reset Button Pressed and Released
Function
About 1 second
Reboot the PoE Injector Hub.
About 8 seconds
Reset the PoE Injector Hub to Factory Default configuration.
The PoE Injector Hub will reboot and load the default IP
settings as shown below.
Be sure that you back up the current configuration of PoE Injector Hub before resetting PoE
Injector Hub or else the entire configuration will be erased when pressing the “RESET” button.
2.1.2 LED Indicators
The front panel LEDs indicates instant status of system power, Management port Link/Active and PoE port links, helps
administrator to monitor and troubleshoot when needed.
LED
Color
Function
FAN1 Failed
Green
Lights to indicate FAN1 has stopped.
FAN2 Failed
Green
Lights to indicate FAN2 has stopped. (Only for HPOE-2400G)
Power1
Failed
Green
Lights to indicate power supply 1 has failed.
Power2
Failed
Green
Lights to indicate power supply 2 has failed. (Only for HPOE-2400G)
Power
Green
Lights to indicate power on.
PoE In-use
Green
Lights to indicate that the port is in use and supplying 48V DC power.
2.1.3 Injector Rear Panel
The rear panel of the PoE Injector Hub indicates an AC inlet power socket, which accepts input power from 100 to 240V
AC, 50/60Hz.
Figures 2-1-4 & 2-1-5
show rear panel of the PoE Injector Hub.
Figure 2-1-4: HPOE-1200G Rear Panel
Figure 2-1-5: HPOE-2400G Rear Panel
13
User’s Manual of HPOE-1200G / HPOE
2400G