![Planet GSW-24040R User Manual Download Page 313](http://html1.mh-extra.com/html/planet/gsw-24040r/gsw-24040r_user-manual_1563253313.webp)
User’s Manual of SGSW-24040 / 24240 Series
313
Object
Description
•
System PoE Admin
Mode
Allows user enable or disable PoE function. It will causes all of PoE ports supply
or not supply power.
•
Power Management
Mode
There are five modes for configuring how the ports/PDs may reserve power and
when to shut down ports.
Classification mode
Allocation mode
Consumption mode
Priority mode
The default PoE management mode is “Consumption
mode
”.
•
Power Supply Budget
[W]
Set limit value of the total PoE port provided power to the PDs.
For
SGSW-24040P
, the available max. value is
220
, for
SGSW-24040P4
, the
available max. value is
380
, and for
SGSW-24040HP
, the available max. value is
360
.
•
Temperature
Threshold
Allows setting over temperature protection threshold value. It system
temperature was over it then system lower total PoE power budget automatically.
•
PoE Usage Threshold
Allows setting how much PoE power budget could be limited.
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.
For
SGSW-24040P
, the total PoE power reservation from Port-1~24 is up to
220W
For
SGSW-24040P4
, the total PoE power reservation from Port-1~24 is up to
380W
For
SGSW-24040HP
, the total PoE power reservation from Port-1~24 is up to
360W
PD Classifications
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is
to provide information about the maximum power required by the PD during operation.
Class 0
is the default for PDs. However,
to improve power management at the PSE, the PD may opt to provide a signature for
Class 1 to 4
.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input
voltages and operational modes.
A PD shall return Class 0 to 4 in accordance with the maximum power draw as specified by
Table 4-16-1.
Class
Usage
Range of maximum power used by the PD
Class Dsecription
0
Default
0.44 to 12.95 Watts
Classification unimplement
1
Optional
0.44 to 3.84 Watts
Very low power