background image

 

 

 

10/100/1000Mbps 

Gigabit Ethernet Web-manageable Switch 

 

GSW-1402S 

 

User

s Manual 

 

 

 

 

Summary of Contents for GSW-1402S

Page 1: ...10 100 1000Mbps Gigabit Ethernet Web manageable Switch GSW 1402S User s Manual ...

Page 2: ...ke improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules The...

Page 3: ...AIN MENU 5 3 3 SYSTEM MENU 6 3 4 MANAGEMENT SETUP MENU 7 3 5 DEVICE CONTROL MENU 8 3 6 USER AUTHENTICATION MENU 12 3 7 SYSTEM UTILITY MENU 12 4 WEB MANAGEMENT 15 4 1 START A WEB BROWSER SESSION 15 4 2 MAIN PAGE 15 4 3 SYSTEM PAGE 17 4 4 PORT PAGE 18 4 5 VLAN PAGE 19 4 6 PORT AGGREGATION PAGE 21 4 7 MIRROR PAGE 21 5 SWITCH OPERATION 22 5 1 ADDRESS TABLE 22 5 2 LEARNING 22 5 3 FORWARDING FILTERING 2...

Page 4: ...APPENDIX A 25 A 1 SWITCH S RJ 45 PIN ASSIGNMENTS 25 A 2 10 100MBPS 10 100BASE TX 25 A 3 RJ 45 CABLE PIN ASSIGNMENT 25 ...

Page 5: ... is also support two module slots for 10 100 1000Base T 1000Base SX and 1000Base LX modules to uplink to a server or network backbone These Switches are designed for Plug and Play installation allows the network administrator to simply connect the network and power cables and the Switching bridging functions begin automatically The front panels of these Switches provide LEDs for easy recognition o...

Page 6: ...ckets of a specific port MDI MDI X Auto MDI MDI X on each port LEDs System PWR Status Per port ACT 10 100 1000 Port Module LNK ACT Cables 10Base T 2 pair UTP Cat 3 4 5 up to 100m 100Base TX 2 pair UTP Cat 5 up to 100m 1000Base T 4 pair UTP Cat 5 up to 100m 1000Base SX 50 125 and 62 5 125 fiber optic cable up to 550m 1000Base LX 9 125 fiber optic cable up to 10km 50 125 and 62 5 125 fiber optic cab...

Page 7: ...t front panel provides a simple interface monitoring the switching hub GSW 1402S Switch front panel LED indicators PWR Green On power on STATUS Green On System is OK Blink Run Time Error occurs ACT Green Blink there is traffic transverses the port 10 100 LNK 1000 Green On indicate link status and traffic speed 10 for 10Mbps 100 for 100Mbps 1000 for 1000Mbps Reset button At the right side of front ...

Page 8: ...lowing the same process as described in Step 2 Notice Cable distance for Switch The cable distance between Ethernet Switch and hub PC should not exceed 100 meter for UTP STP cable 220m for 62 5 125 fiber cable and 550m for 50 125 fiber cable if use 1000Base SX module 550m for 62 5 125 or 50 125 fiber cable and 10km for 9 125 fiber cable if use 1000Base LX module Make sure the wiring is correct It ...

Page 9: ...login screen appears as below Enter username and password to access GSW 1402S There are three system default accounts for different privilege levels root root can do any configuration includes changing password and enable disable management capability via console port The default password of root is superuser Note that this account is not workable on telnet and web management interface admin admin...

Page 10: ...System Information This screen shows the hardware and software versions of current switch Moreover information of System Contact Device Name and Device Location also included 3 3 2 System Configuration Select 2 from System Menu to configure System Contact Device Name and Device Location System Contact Who the System administrator is optional Device Name Naming the system optional Device Location W...

Page 11: ... Menu use option 6 to save changes to NVRAM Moreover the IP addresses of switch and Default Gateway have to be in the same IP segment otherwise GSW 1402S will not apply such configuration 3 4 2 Console Port Status Display To display the parameters used for console port access select 2 from Management Setup Menu 3 4 3 Management Features Control This screen allows user to control web and telnet man...

Page 12: ...ion Trunk 3 5 1 Port Status Configuration From Device Control Menu select 1 to enter Port Status Configuration Menu To display the status of each port select 1 from Port Status Configuration Menu This screen contains information of port number connection type Admin management link status link speed duplex and flow control To modify port name Admin status link speed duplex and flow control select 2...

Page 13: ... PVID 1 Moreover all ports of an Aggregation Group must be treated as an integer when added to deleted from a VLAN The IEEE802 1Q TAG VLAN Menu displays VLAN ID range maximum number of supported VLANs the number of created VLANs and active VLANs Moreover this menu provides four options including VLAN Port Configuration VLAN Table Status VLAN Static Entry Created VLAN Static Entry Modification and ...

Page 14: ...Menu Choose which VLAN you want to delete After deletion system will return to IEEE802 1Q TAG VLAN Menu You can use option 2 to check if the deletion is successfully done or not 3 5 3 Mirror Port mirror is used to mirror traffic from source port to a target port for analysis Up to 2 ports can be monitored mirrored simultaneously by 1 sniffer port target port Please note that the target port must b...

Page 15: ...rt numbers If you want to enter two numbers please use a comma between numbers 3 5 4 Port Aggregation Port Aggregation Port Trunk is used to increase the bandwidth of a switch to switch connection GSW 1402S provides 8 port aggregation groups Each group consists of 2 ports and creates bandwidth up to 4Gbps at full duplex mode To enter Port Aggregation Menu select 4 from Device Control Menu This scr...

Page 16: ...h two slide in slots should use the identical modules two coppers two fibers otherwise the Port Aggregation connection is invalid 3 6 User Authentication Menu User Authentication Menu shows the three sets of username and password of GSW 1402S To change the password enter one available value after the command prompt Then assign a new password to it 3 7 System Utility Menu System Utility Menu provid...

Page 17: ...ity Menu The default settings will display as follow 3 7 4 1 Modify Download Filename To specify the download filename select 1 from TFTP Menu Then enter the filename of target file 3 7 4 2 Modify TFTP Server IP To change the IP address of TFTP server select 2 from TFTP Menu Then enter the correct IP 3 7 4 3 Start TFTP Download After all above parameters are properly configured select 3 from TFTP ...

Page 18: ...ect IP 3 7 5 3 Start Ping After all above parameters are properly configured select 3 from Ping Menu to start ping test System will show the test result as follow 3 7 6 Search Location by Port Name This function is designed to ease the management difficulties Type an existing port name then system will display matched port number s on screen 3 8 Save Runtime Configuration To save all current Runti...

Page 19: ...can download from http java sun com j2se 1 3 download html and manually install it Note Usually the newer Java TM Virtual Machine is not backward compatible JVM version 1 3 1 is strongly recommended to ensure properly operation The default network configurations are as follows IP 192 168 0 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 0 254 Activate a web browser and enter 192 168 0 1 in the...

Page 20: ...button enables user to reset GSW 1402S to factory default values After click on it the following message box appears Click Yes to reset switch click No to abort 4 2 3 Reboot This button enables user to reboot switch without unplug the power cord After click on it the following message box appears Select boot type Warm Boot or Cold Boot Then click OK to reboot or click Close to abort 16 ...

Page 21: ...y connect to switch 4 2 6 Contact This button enables user to send mail to PLANET support team After click on it the mailing software such as Outlook will be activated and generate a new mail automatically 4 2 7 Upgrade This button enables user to upgrade firmware for switch After click on it the following message box appears Select upgrade type WEB Upload or TFTP Download Click OK to start upgrad...

Page 22: ...ne time Please follow the procedures below 1 Click Configuration tab in Port Page 2 Click Duplicate button the dialogue screen appears 3 Select Source Port for example Port 2 4 Select Target Port click All to select all for example Port 8 9 10 5 Select the port attributes you want to duplicate 6 Click OK to submit values 7 Click Apply button to apply settings 8 As the following result port 2 is du...

Page 23: ...activate the VLAN or leave it blank and activate it afterward 4 Click Add button to create the new VLAN 4 5 1 2 To Remove A VLAN Group 1 Select a VLAN group you want to remove from the Current list 2 Click Remove button to remove it Note 1 If a removed port is no longer belong to any other group it is temporarily disabled because no one can communicate with it 2 If one port s PVID is equal to this...

Page 24: ... with it 2 The port which is assigned a PVID and the PVID is equal to VLAN ID removing the port will not allow until you change it 4 5 3 VLAN Port Configuration When the VLAN enabled switch receives an untagged packet the packet will be sent to the port s default VLAN according to the PVID port VLAN ID of the receiving port 4 5 3 1 To Change The PVID 1 Double click the PVID column of a port 2 Inpu...

Page 25: ...up in the Status Enable column and press Apply 4 7 Mirror Page This screen shows Mirror status Monitored port number and Sniffer port number Please refer to section 3 5 3 Mirror for further details To set the Mirror function please follow the procedures below 1 Click Active radio button to activate port mirror 2 Select Monitored Ports up to 2 ports 3 Click Sniffer Port combo box and select a sniff...

Page 26: ...of packet forwarding techniques A Store and Forward Switching stores the incoming frame in an internal buffer do the complete error checking before transmission Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forward...

Page 27: ...eds at the second of both device is connected and capable of Both 10Base T and 100Base TX devices can connect with the port in either Half or Full Duplex mode 1000Base T and 1000Base SX can only connect in Full duplex mode ...

Page 28: ...ording to instructions in this manual The Link LED is not lit Solution Check the cable connection and remove duplex mode of the Giga Switch Some stations can not talk to other stations located on the other port Solution The address table may contain older information than of the address table of that node Please power down to refresh the address information ...

Page 29: ...C BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Implicit implementation of the crossover function within a twisted pair cable or at a wiring panel while not expressly forbidden is beyond the scope of this standard A 2 10 100Mbps 10 100Base TX Contact MDI MDI X 1 1 3 2 2 6 3 3 1 6 6 2 A 3 RJ 45 cable pin assignment 21 3 6 1 2 3 6 21 3 6 EM GSW14V1 ...

Reviews: