Standard, VLAN and Extend Operation Modes Offered

PLANET FGSW 802.3at PoE+ Switch series provides Standard, VLAN and Extend 
operation modes. The FGSW 802.3at PoE+ Switch series operates as a normal 
IEEE 802.at/af PoE Switch in the Standard operation mode. The VLAN operation 
mode features the port-based VLAN function that can help to prevent the IP 

camera’s multicast or broadcast storm from influencing each other.

VLAN Isolation Mode

Ports 17 and 18

Ports 1~16 Access Permitted

FGSW-1822VHP

PC

Ports 1 to 16

Access Denied

PoE

PoE

PoE

1000

1000BASE-SX/LX Fiber-optic

1000

100BASE-TX UTP

PoE

100BASE-TX UTP with PoE

IP Camera

IP Camera

IP Camera

NVR

Standard

VLAN

 

<

Extend

In the Extend operation mode, the FGSW 802.3at PoE+ Switch series operates on 
a per-port basis at 10Mbps duplex operation but can support 30-watt PoE power 
output over a distance of up to 250 meters overcoming the 100m limit on Ethernet 
UTP cable. With this brand-new feature, the FGSW series provides an additional 
solution for 802.3af/at PoE distance extension, thus saving the cost of Ethernet 
cable installation. Its VLAN isolation function isolates ports so as to prevent 

broadcast storm and defend DHCP spoofing in the Extend operation mode.

Standard Mode (default)

Power

PoE

100 meters (328 feet)

FGSW-1822VHP

PoE

100BASE-TX UTP with PoE

PoE IP Camera

Standard

 

<

VLAN
Extend

Extend Mode

Power

250 meters (820 feet)

PoE

FGSW-1822VHP

PoE

10BASE-T UTP with PoE

PoE IP Camera

Standard
VLAN

Extend

 

<

Summary of Contents for FGSW-1822VHP

Page 1: ...16 24 Port 10 100TX 802 3at PoE 2 Port Gigabit TP 2 Port SFP Ethernet Switch with LCD PoE Monitor FGSW 1822VHP FGSW 2622VHP User s Manual ...

Page 2: ...All brand and product names mentioned in this manual are trademarks and or registered trademarks of their respective holders Trademarks PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their re spective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applica tions and makes no warranty and re...

Page 3: ...ll be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic eq...

Page 4: ...Enable 22 2 3 5 PD Type 22 2 3 6 Alive Check 23 2 3 7 Bandwidth Detection 24 2 3 8 Fan Control 24 2 3 9 Screen Saver 25 2 3 10 Language 25 2 3 11 Default Setting 26 2 3 12 System 26 3 Hardware Installation 27 3 1 Desktop Installation 28 3 2 Rack Mounting 29 3 3 Installing the SFP Transceiver 30 3 4 Product Applications 32 3 5 Power over Ethernet Powered Devices 33 4 Power over Ethernet Overview 34...

Page 5: ...bit TP 2 Port SFP Ethernet Switch with LCD PoE Monitor 802 3at PoE Switch is used as an alternative name in this user s manual 1 1 Package Contents Open the box of the 802 3at PoE Switch and carefully unpack it The box should contain the following items 802 3at PoE Switch x 1 User s Manual x 1 Power Cord x 1 Accessories x 1 If any of these pieces are missing or damaged please contact your dealer i...

Page 6: ... provides multiple 10 100 Mbps 802 3at af PoE ports able to feed numerous IEEE 802 3at PoE IP cameras with sufficient PoE power It is also able to be connected with an 8 16 32 channel NVR system and uplinked to the backbone switch and the monitoring center With such a high performance switch architecture the recorded video files from the PoE IP cameras can be saved in the NVR system to enable the ...

Page 7: ... with each port taking up 30 watts of PoE power and 2 Gigabit TP and 2 Gigabit SFP interfaces with inner power system With a total PoE power budget of 300 watts and non blocking data switching performance the FGSW 1822VHP can fulfill the demand of sufficient PoE power for HD IP surveillance It offers a desktop sized reliable and visible power solution for small businesses and system integrators de...

Page 8: ...20 22 24 18 17 19 21 23 FGSW 2622VHP Menu 5 sec Enter Back PWR Up Down Gigabit 25 27 26 28 PoE 1 2 5 6 9 10 13 14 17 18 21 22 3 4 7 8 11 12 15 16 19 20 23 24 PoE In Use ACT LNK 26 25 28 27 ACT LNK 10 100 1000 Main Menu 01 02 03 05 06 07 08 Switch Mode Budget Control PSE Port Priority PD Type Alive Check Bandwidth Fan Control 04 PSE Port Enable Switch Mode Options Standard VLAN Extend Bandwidth Use...

Page 9: ...Camera IP Camera NVR Standard VLAN Extend In the Extend operation mode the FGSW 802 3at PoE Switch series operates on a per port basis at 10Mbps duplex operation but can support 30 watt PoE power output over a distance of up to 250 meters overcoming the 100m limit on Ethernet UTP cable With this brand new feature the FGSW series provides an additional solution for 802 3af at PoE distance extension...

Page 10: ...bility and protects users networks from devastating ESD attacks making sure the flow of operation does not fluctuate Easy Installation and Cable Connection As data and power are transmitted over one cable the FGSW 802 3at PoE Switch series does not need a second cable and electrical outlets on the wall ceiling or any unreachable place Thus it helps to lower the installation costs and simplify the ...

Page 11: ...w voltage power over voltage and PSE over temperature protection Screen saver fan control factory default and save configuration PoE management Total PoE power budget control Per port PoE function enable disable PoE port power feeding priority Per PoE port power limitation PD alive check Switching Hardware based 10 100Mbps or 10 100 1000Mbps auto negotiation and auto MDI MDI X Flow control for ful...

Page 12: ...ts 2 1000BASE X SFP mini GBIC Slots 2 Switch Architecture Store and Forward Switch Fabric 11 2Gbps non blocking 12 8Gbps non blocking Switch Throughput 64 bytes 8 3Mpps 64 bytes 9 5Mpps 64 bytes MAC Address Table 8K entries Maximum Frame Size 9216 bytes Flow Control IEEE 802 3x pause frame for full duplex back pressure for half duplex LED System Power Green 10 100BASE TX RJ45 Interfaces 10 100Mbps...

Page 13: ... 30 watts IEEE 802 3at Power Pin Assignment 1 2 3 6 PoE Power Budget 300 watts Max Number of Class 2 PDs 16 24 Max Number of Class 3 PDs 16 23 Max Number of Class 4 PDs 11 11 Standards Conformance Regulatory Compliance FCC Part 15 Class A CE Standards Compliance IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX IEEE 802 3ab Gigabit 1000BASE T IEEE 802 3z Gigabit SX LX IEEE 802 3x Flow control and back pr...

Page 14: ...2 W M M W 03 M M 15 4W 04 10M M W 05 M M 06 W M M 07 W M M 08 W M M 8 3 09 W M 11M 10 W M M OFF 11 M M 12 W M M 17 6W 13 11M 12M 14 W M M PB 300W TP 72W PD 4 Figure 2 1 FGSW 1822VHP Switch Front Panel 4 6 8 2 1 3 5 7 12 14 16 10 9 11 13 15 20 22 24 18 17 19 21 23 FGSW 2622VHP Menu 5 sec Enter Back PWR Up Down Gigabit 25 27 26 28 PoE 1 2 5 6 9 10 13 14 17 18 21 22 3 4 7 8 11 12 15 16 19 20 23 24 Po...

Page 15: ...W M M W 03 M M W 04 M M W 05 M M 06 W M M 07 W M M 08 W M M 09 W M M 10 W M M 11 W M M 12 W M M 13 W M M 14 W M M WARNING The PSE device is too hot All ports had shut down Switch Port Information PD 0 PB 300W TP 0W 01 W M M 02 W M M W 03 M M W 04 M M W 05 M M 06 W M M 07 W M M 08 W M M 09 W M M 10 W M M 11 W M M 12 W M M 13 W M M 14 W M M WARNING Main supply voltage is low All ports had shut down ...

Page 16: ...ta transmission rate while the red character represents the data transmission rate which is greater than the bandwidth setting causing power to restart the PSE port If the resumption situation happens for 10 times within 1 hour the power supply to the port will be cut off PB It means power budget TB It means total PoE power output information PD The number of PDs inserted 2 1 2 LED Indicators Syst...

Page 17: ...lectrical outlet standard in most areas of the world the 802 3at PoE Switch s power supply automatically adjusts to line power in the range of 100 240V AC and 50 60Hz 5A Plug the female end of the power cord firmly into the receptacle on the rear panel of the 802 3at PoE Switch and the other end into an electrical outlet and the power will be ready Power Notice The device is a power required devic...

Page 18: ...M M 06 W M M 07 W M M 08 W M M 8 3 09 W M 11M 10 W M M OFF 11 M M 12 W M M 17 6W 13 11M 12M 14 W M M PB 300W TP 72W PD 4 Press the menu button to switch the Switch Port Information Press the menu button for about 5 seconds and enter the Main Menu Choose a menu item by scrolling up and down and press the Enter key to get to the menu item you have chosen Press the Back key to return to the previous ...

Page 19: ...tion switch and 1 Port 1 to port 24 will isolate respectively 2 Port 1 to port 24 can only communicate with port 25 and port 26 uplink port Extend With VLAN Isolation This mode makes the FGSW 1822VHP operate as a VLAN isolation switch and 1 Port 1 to port 16 will isolate respectively 2 Port 1 to port 16 can only communicate with port 17 and port 18 uplink port 3 30 watt PoE transmit distance of 25...

Page 20: ...2VHP PoE 10BASE T UTP with PoE PoE IP Camera Standard VLAN Extend VLAN Isolation Feature The 802 3at PoE Switch has one feature called VLAN function When switching the mode to the VLAN position port 1 to port 16 24 wouldn t able to communicate with each other 4 6 8 2 1 3 5 7 12 14 16 10 9 11 13 15 FGSW 1822VHP Menu 5 sec Enter Back 1 PWR Up Down 5 9 13 3 7 11 15 PoE 2 6 10 14 4 8 12 16 PoE In Use ...

Page 21: ...get is 300W in Unchanged mode If you hope to have a full load of over 300W please select Add 5 PB Add 10 PB and Add 15 PB 2 In order to make sure the PSE power supply is not overloaded for a long time please try to ensure that TP is less than PB 2 3 3 PSE Port Priority The Priority represents PoE ports priority There are three levels of power priority named Low High and Critical The priority is us...

Page 22: ...r up mode to be in Enhance mode Standard mode or Legacy mode by the user interface Object Description Enhance default On the basis of standard mode change the PD of class 0 to AT mode in addition the current surge limit during power up increases to the current limit of AT Standard Fully conforms to the IEEE 802 3af at standard Legacy The legacy detection is to identify the PD devices that did not ...

Page 23: ...l ports are disabled as default value Startup Time 60 300s PD startup time This startup time is based on determining when to start to measure the traffic The default startup time is 180 seconds Interval Time 60 300s Traffic detection counter The switch detects no traffic during this time and countdown for interval time begins and port begins to reboot The default interval time is 180 seconds Power...

Page 24: ... you set it longer 2 3 7 Bandwidth Detection When the network transmits of single port highest data rate more than the set value the switch will set off an alarm to warn the overuse of the bandwidth There are four levels of budget control namely Unlimited default 70Mbps 80Mbps and 90Mbps Bandwidth Detection Options Unlimited 90Mbps 70Mbps 80Mbps UP Down Select Enter Confirm Back Return Current Set...

Page 25: ...25 2 3 9 Screen Saver There are four levels of budget control namely Always ON 10min default 20min and 30min 2 3 10 Language There are two languages namely English and Chinese ...

Page 26: ...26 2 3 11 Default Setting Press Yes to reset to default 2 3 12 System Show the system information ...

Page 27: ...d then turn on the 802 3at PoE Switch The port will automatically run in 10Mbps 20Mbps 100Mbps or 200Mbps and 1000Mbps or 2000Mbps after the negotiation with the connected device Cabling Each 10 100BASE TX port and 10 100 1000BASE T port uses RJ45 sockets similar to phone jacks for connection of unshielded twisted pair cable UTP The IEEE 802 3 802 3u 802 3ab Fast Gigabit Ethernet standard requires...

Page 28: ...cts Note When choosing a location please keep in mind the environmental restrictions discussed in Chapter 1 Section 4 under Specifications Step 4 Connect your 802 3at PoE Switch to 802 3af 802 3at complied power devices PD and other network devices A Connect one end of a standard network cable to the 10 100BASE TX RJ45 ports on the front panel of the 802 3at PoE Switch B Connect the other end of t...

Page 29: ...2 Attaching the Brackets to the 802 3at PoE Switch You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect screws would invali date the warranty Step 3 Secure the brackets tightly Step 4 Follow the same steps to attach the second bracket to the opposite side Step 5 After the brackets are attached to the 802 3at PoE Switch use suitable screws to sec...

Page 30: ...t of approved PLANET SFP transceivers is correct at the time of publication Gigabit SFP Transceiver Modules MGB GT SFP Port 1000BASE T Module MGB SX SFP Port 1000BASE SX mini GBIC module 550m MGB LX SFP Port 1000BASE LX mini GBIC module 10km MGB L30 SFP Port 1000BASE LX mini GBIC module 30km MGB L50 SFP Port 1000BASE LX mini GBIC module 50km MGB L70 SFP Port 1000BASE LX mini GBIC module 70km MGB L...

Page 31: ...e duplex LC connector type To connect to 1000BASE LX SFP transceiver please use the single mode fiber cable with one side being the male duplex LC connector type Connect the Fiber Cable 1 Insert the duplex LC connector into the SFP transceiver 2 Connect the other end of the cable to a device with SFP transceiver installed 3 Check the LNK ACT LED of the SFP slot on the front of the 802 3at PoE Swit...

Page 32: ...mera system and wireless AP group for enterprises Cameras can be installed around the corner in the company or campus for surveillance demands Without the power socket limitation the 802 3at PoE Switch makes the installation of cameras easier and more efficient PoE PoE PoE DC 802 3af Splitter Phone Camera Laptop N N PoE VoIP ATA PoE IP Camera Core Switch PoE Wireless AP PC Group PC Group PoE PoE V...

Page 33: ...t worrying about power outlet locations thus eliminating the costs for additional AC wiring and reducing the installation time 3 25 watts High Power PoE Splitter As PoE Splitter splits the PoE 53 to 54V DC over the Ethernet cable into 24 12V DC power output network deployments can easily be made without worrying about power outlet locations thus eliminating the costs for additional AC wiring and r...

Page 34: ... a powered device from using all four pairs for power The 802 3af 802 3at define two types of source equipment mid span and end span Mid span Mid span device is placed between legacy switch and the powered device Mid span taps the unused wire pairs 4 5 and 7 8 to carry power the other four are for data transmit End span End span device is directly connected with power device End span could also ta...

Page 35: ... of PoE supplied power failure How Power is Transferred through Cable A standard Cat5 Ethernet cable has four twisted pairs but only two of these are used for 10BASE T and 100BASE TX The specification allows two options for using these cables for power shown in Figure 1 and Figure 2 The spare pairs are used Figure 1 shows the pair on pins 4 and 5 connected together and forming the positive supply ...

Page 36: ... 2 3 6 7 8 Converter Figure 2 Power Supplied over the Data Pins When to install PoE Consider the following scenarios z z You re planning to install the latest VoIP phone system to minimize cabling building costs when your company moves into a new office next month z z The company staff has been clamoring for a wireless access point in the picnic area behind the building so they can work on their l...

Page 37: ...itch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn on the power again Why the FGSW 1822VHP FGSW 2622VHP connected to PoE device can not be powered on Solution 1 Please check the cable type of the connection from FGSW 1822VHP FGSW 2622VHP to the other end The cable should be an 8 wire UTP Category 5 or above and EIA568 cable wi...

Page 38: ...BASE TX When connecting Switch to another Fast Ethernet switch a straight through or crossover cable might be necessary Each port of the Switch supports auto MDI MDI X detection meaning you can directly connect the Switch to any Ethernet devices without making a crossover cable The following table and diagram show the standard RJ45 receptacle connector and their pin assignments RJ45 Connector Pin ...

Page 39: ...3 4 5 6 7 8 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 1 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown Figure A 1 Stra...

Page 40: ...luation regarding the EMC the following standards were applied EN 55022 2010 AC 2011 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55024 2010 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 Responsible for making this declaration if the Manufacturer Authorized representative established within the EU Authorized representative established within the EU if applicable Company Name Planet Technology Corp C...

Reviews: