background image

 

EV-401M / EV-401S User's Manual

 

 7 

central side. If you want to setup one pair of converters for 
point-to-point connection then one set must be client mode 
and the other one is master mode. 

The cable specifications of the connection are listed as 
following: 

 

10BASE-T, Category 3, 4 or 5 UTP 

 

100BASE-TX, Category 5 UTP 

 

Ethernet over VDSL, Twisted-pair telephone wires 

The two drawings listed below are typical application for 
the Ethernet over VDSL converter. 

 

Drawing 1: LAN to LAN connection 

 

 
 
 
Drawing 2: Multi-port Master Connection 

 

 
 

 
 
 

Note: Slave device must connect to Master device through 

the telephone wire.  Slave cannot connect to Slave 
and Master cannot connect to Master.  EV-401M 
works as Master device and EV-401S works as Slave 
device.

 

Multi-Port Master 

Summary of Contents for Ethernet Over VDSL Converter EV-401M

Page 1: ...Ethernet Over VDSL Converter EV 401M EV 401S User s Manual...

Page 2: ...tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications...

Page 3: ...NEL 11 2 2 REAR PANEL 13 3 INSTALLING AND USING ETHERNET OVER VDSL CONVERTER 15 3 1 INSTALL THE ETHERNET OVER VDSL CONVERTER 15 3 2 LAN TO LAN CONNECTION 16 3 3 CONNECT TO MULTI PORT MASTER 16 3 4 INS...

Page 4: ...PLANET Ethernet over VDSL series 4 This page intentionally left blank...

Page 5: ...hernet over VDSL Converter User s manual Power cord Telephone line If any of these pieces are missing or damaged please contact your dealer immediately if possible retain the carton including the orig...

Page 6: ...existing phone line to transmit data to the Internet and the whole building could share the Internet line to the wide area network with minimum cost With much enough bandwidth the 10Mbps symmetric cap...

Page 7: ...4 or 5 UTP 100BASE TX Category 5 UTP Ethernet over VDSL Twisted pair telephone wires The two drawings listed below are typical application for the Ethernet over VDSL converter Drawing 1 LAN to LAN co...

Page 8: ...Ethernet over VDSL port one for LAN connection and one for voice connection Supports one 10Mbps symmetric Ethernet over VDSL port Based on different phone line quality the distance could extend up to...

Page 9: ...wires AWG26 or better to 1 2km 4000 ft Modes Half and Full Duplex auto negotiation MAC address 4K entries Buffer memory 128K bytes Forwarding Mode Store and forward Packet Forwarding Rate 64bytes 1488...

Page 10: ...PLANET Ethernet over VDSL series 10 This page intentionally left blank...

Page 11: ...of incoming connection This section describes the hardware features of these Converters For easier control of the converter familiarize yourself with its display indicators and ports Front panel illus...

Page 12: ...LED Steady Green The 100M LED indicates the link speed of each port If the LED light green then the connection speed is 100Mbps 100M 10M Off Link speed is 10Mbps Steady Green Every port has a Link Act...

Page 13: ...extend up to 1 2km 4000ft with AWG 26 0 4mm telephone wire The distance will change by the quality of cable default mode ASYM It provides 3M upstream and 10M downstream It will extend up to 1 35km 450...

Page 14: ...orks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge su...

Page 15: ...like telephone and the other one for network link connection Depending on the quality of telephone line the maximum distance of one VDSL segment is 1 2km 4000ft with AWG 26 telephone wires The distanc...

Page 16: ...be Master and the other one is Slave 3 3 Connect to Multi Port Master In order to built up a local internet in apartment hotel campus and hospitality environment The Internet Access Concentrators need...

Page 17: ...verter on the desktop then we need to know how to connect the device to network 3 5 Station Connections with Telephone Wires Connect the network adapters in stations to the converter s 10 100Mbps swit...

Page 18: ...PLANET Ethernet over VDSL series 18 This page intentionally left blank...

Page 19: ...ides the source address learning The switch will look up the address table for the destination address If not found this packet will be forwarded to all the other ports except the source port If found...

Page 20: ...PLANET Ethernet over VDSL series 20 This page intentionally left blank...

Page 21: ...d EV 401S is not more than 1 5km 2 Please note you must use 1 EV 401M and 1 EV 401S connect to each other to make it work SYMPTOM Switch Link Act LED not lit after cable is connected to the port CHECK...