Initial Setup 

Steps shown in Figure 3 may be followed for the initial setup of the ThermaCheck M1 camera.  The camera head 

mounts to a 1/4-20" threaded screw (a standard for camera tripods). Typical mounting hardware for the 

ThermaCheck M1 camera is shown in Section 7.   

Steps:   1) Mount the camera in a suitable screening location. Please see Section 6 for additional screening location 

requirements.  

 

2) Connect camera head to power adaptor through the red 12V connector on the camera’s rear pig-tail.   

 

3) Connect power adapter to the wall outlet.   

 

4) Connect camera head to a display (not provided) using the HDMI cable provided.   

 

5) Connect provided mouse to camera head through the USB connector on the camera’s rear pig-tail.  The 

mouse need only be connected to the camera while changing settings though the UI.  During normal 

screening operation, the mouse may be disconnected. 

 

Figure 3: Schematic of the ThermaCheck M1 initial setup. 

Notes: 

1)

 

Camera should be mounted so that screening subjects are 1-4m from the camera. 

2)

 

ThermaCheck M1 camera has many real ports to enable integration with access control systems.  Please 

contact 

[email protected]

 for additional information.

 

Summary of Contents for TC160M1

Page 1: ...rface Functions 5 5 1 System settings and information 5 5 2 Interactive calibration function 5 5 3 Mask Detection 7 5 4 Screening Capture History 7 5 5 Temperature Threshold Setting 7 6 Temperature Sc...

Page 2: ...subjects face The M1 Series camera may be used to screen subjects for wearing a mask issuing an alert in the case of noncompliance Recent individual screening results are summarized in a bottom pictur...

Page 3: ...nector on the camera s rear pig tail 3 Connect power adapter to the wall outlet 4 Connect camera head to a display not provided using the HDMI cable provided 5 Connect provided mouse to camera head th...

Page 4: ...4 ThermaCheck M1 main display Table 1 Main display features UI Feature Description 1 Cameras Realtime view of visible and thermal cameras 2 Screening Bar Dynamically refreshed recent screening results...

Page 5: ...the mouse the appropriate display icon The ThermaCheck M1 camera settings are described below 5 1 System settings and information System Tab 1 Selection of the date time field opens a dialog box for...

Page 6: ...A approved device is preferred If using a blackbody subject set setpoint temperature to 95 97 F 35 36 C and allow the blackbody to reach the setpoint temperature before calibration is started 3 Use th...

Page 7: ...on choose the date and screening record type Normal High Temp No Mask to perform a search of the screening record as shown in Figure 9 Figure 9 Selecting record type for search of the screening record...

Page 8: ...rea Figure 11 Adverse environmental conditions for the ThermaCheck M1 camera Notes 1 Temperature measurements of subjects entering the screening area from the outside could be affected if there is a s...

Page 9: ...le temperature source used in the factory calibration of thermal cameras to make their temperature measurements as accurate as possible Some infrared cameras used for human temperature screening requi...

Page 10: ...rature is influenced by environmental conditions Individuals with abnormal skin temperature readings should be further evaluated with a medical grade thermometer Planck Vision Systems is not advertisi...

Reviews: