Important Safety Instructions 

 

Please read the following instructions carefully. This manual should be retained for future use.   

1.

 

To clean LCD Monitor screen;   
-- Power off LCD Monitor and unplug the AC Cord.   

 

-- Spray a non-solvent cleaning solution onto a rag.   
-- Gently clean the screen with dampened rag.   
 

2.

 

Do not place the LCD Monitor near a window. Exposing the monitor to rain water,   

      moisture or sunlight can severely damage it. 
 

3.

 

Do not apply pressure to the LCD screen. Excess pressure may cause permanent damage to the display.   

 

4.

 

Do not remove the cover or attempt to service this unit by yourself. Servicing of any nature should be 
performed by an authorized technician.   

 

5.

 

Store LCD Monitor in a room with a room temperature of -20° ~ 60°C (or -4° ~ 140°F). Storing the LCD 
Monitor outside this range could result in permanent damage.   

 

6.

 

If any of the following occurs, immediately unplug your monitor and call an authorized technician.   
*    Monitor to PC signal cable is frayed or damaged.   
*    Liquid spilled into LCD Monitor or the monitor has been exposed to rain.   
*    LCD Monitor or the case is damaged.   
 

7.

 

Only use the supplied main lead to connect the monitor. For a nominal current up to 6A and a device weight 
above 3 kg, a line not lighter than H05VV-F, 3G, 0.75 mm

2

 must be used. 

 

Important Recycle Instruction: 

 

LAMP(S) INSIDE THIS PRODUCT CONTAIN MERCURY AND MUST BE RECYCLED 
OR DISPOSED OF ACCORDING TO LOCAL, STATE OR FEDERAL LAWS. FOR MORE 
INFORMATION, CONTACT THE ELECTRONIC INDUSTRIES ALLIANCE AT 
WWW.EIAE.ORG. FOR LAMP SPECIFIC DISPOSAL INFORMATION CHECK 
WWW.LAMPRECYCLE.ORG. 

Contains Mercury, Dispose of Properly 

 

Summary of Contents for PL1910MW

Page 1: ......

Page 2: ...erface for Arm Applications 5 Connecting the Display 5 Connecting the AC Power 6 Connecting the Audio Cable 6 Setting Up the LCD Monitor 6 Power Management System 6 Display Controls 7 User Controls 7...

Page 3: ...tion Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception whichcanbe determinedbyturningtheequipmentoffandon theuserisencouragedtotrytocorrecttheinterferencebyoneormoreof thefollowi...

Page 4: ...om with a room temperature of 20 60 C or 4 140 F Storing the LCD Monitor outside this range could result in permanent damage 6 If any of the following occurs immediately unplug your monitor and call a...

Page 5: ...ent airflow Though the LCD Monitor uses very little power some ventilation is needed to ensure that the Monitor does not become too hot After you unpack the LCD Monitor make sure that the following it...

Page 6: ...e hinge to release Figure 1 3 Interface for Arm Applications Before installing to mounting device please refer to Fig 1 3 The rear of this LCD display has four integrated 4 mm 0 7 pitch threaded nuts...

Page 7: ...er cord is connected to the LCD Monitor 2 Turn on the LCD Monitor s power switch located on the bezel of the monitor Power Management System This LCD Monitor complies with the VESA DPM Power Managemen...

Page 8: ...de be dark when monitor in off mode 2 Power ON OFF switch Push to power on or power off Toggle switch 3 Menu Enter Shows main OSD menu Enter key in OSD menu Audio mute and unmute must activate Volume...

Page 9: ...ptimal balance of brightness and contrast prevent eyestrain The most comfortable way to read onscreen text Preset Mode PHOTO Enhances colors and emphasize fine detail Brightness Adjusts the background...

Page 10: ...color temperature to 7500K 5000K Sets the color temperature to 5000K sRGB Sets the color temperature to sRGB User R G B Allows users to adjust red green blue intensity Language Multi language selectio...

Page 11: ...he CIE coordinate color temperature to 9300 K 7500 CIE coordinated Color Temperature of 7500 K Sets the CIE coordinate color temperature to 7500 K 5000 CIE coordinated Color Temperature of 6500 K Sets...

Page 12: ...mpedance 75 Ohm 2 Polarity Positive Negative Amplitude 0 0 7 0 05 Vp Multi mode Supported Horizontal Frequency 30 80 kHz Vertical Frequency 56 75 Hz 30 80kHz 56 75Hz Control Power switch hard and soft...

Page 13: ...d negative Plug Play Supports VESA DDC2B DDC CI functions External Connection Power Input AC input AC socket Video Cable 15 pin D sub DVI D connector Monitor to PC DVI D Cable Audio Cable Stereo Jack...

Page 14: ...40 64 16 120 VESA 480 75Hz 75 500 480 3 1 16 31 5 720x350 31 47 900 720 108 18 54 70Hz 70 087 449 400 2 37 60 28 322 720x400 31 469 900 720 108 18 54 VGA 400 TEXT 70 087 449 400 2 12 35 28 322 832x624...

Page 15: ...36 126 1280x960 75 1800 1280 112 96 312 75Hz 75 1000 960 3 1 36 135 1280x1024 64 1688 1280 112 48 248 VESA 1024 60Hz 60 1066 1024 3 1 38 108 1280x1024 80 1688 1280 144 16 248 VESA 1024 75Hz 75 1066 10...

Page 16: ...is no picture on LCD Monitor If there s no picture on the LCD Monitor please perform the following steps 1 Make sure the power indicator on the LCD Monitor is ON all connections are secured and the s...