background image

 

                                                             LX1250TI User Manual                                                                                  5 

 

Introduction 

About Planar’s LX1250TI Rugged Touch Monitor 
The LX1250TI is a high-performance, rugged touch monitor intended for demanding environments, 
such as those inside mining vehicles. The monitor features a 12.1-inch diagonal liquid crystal display 
with XGA resolution, bright enough to be read in full sunlight. The monitor also includes a buzzer for 
audio feedback and a sturdy cast aluminum enclosure that can withstand shock and vibration. 

 
 

Product  

This manual applies to product  
 

Planar Part Number 

Planar Model Name 

Description 

UPC  

997-6186-00LF 

LX1250TI 

IR touch 12.1” XGA LCD 
General Market 

8 10689 06186 1 

997-6192-00LF

 

LX1251TI 

IR Touch 12.1” XGA LCD 
General Market –VGA IF 

8 10689 06192 2 

 

 

 

 

Summary of Contents for LX1250TI

Page 1: ......

Page 2: ...d in this document is subject to change without notice This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be reproduced translated to another language or stored in a retrieval system or transmitted by any means electronic mechanical photocopying recording or otherwise with out prior written permission Windows is a regi...

Page 3: ...LLER BOARD 27 PEZIO FUNCTION LX1250TI ONLY 27 MECHANICAL ENCLOSURE 27 CONNECTORS AND I O 27 PHYSICAL SPECIFICATIONS 29 OPTICAL REQUIREMENTS 29 MECHANICAL OUTLINE 30 PRELIMINARY DIMENSIONS 30 VESA MOUNT 31 WEIGHT 31 SHIPPING BOX 31 MAINTENANCE REQUIREMENTS SERVICE SUPPORT 31 SERVICE REQUIREMENTS 31 SERVICE BOM 31 ENVIRONMENTAL SPECIFICATIONS 31 TEMPERATURE 31 HUMIDITY 31 ALTITUDE 31 VIBRATION 31 SH...

Page 4: ...and local laws and regulations to make sure the monitor is used properly and safely Avoid using the monitor for extended times while the vehicle is not running or the monitor could drain the vehicle s battery Cleaning the Monitor Always turn of the unit before cleaning Use a soft cloth moistened with mild detergent isopropyl alcohol or window cleaners to clean the display housing Never use abrasiv...

Page 5: ... crystal display with XGA resolution bright enough to be read in full sunlight The monitor also includes a buzzer for audio feedback and a sturdy cast aluminum enclosure that can withstand shock and vibration Product This manual applies to product Planar Part Number Planar Model Name Description UPC 997 6186 00LF LX1250TI IR touch 12 1 XGA LCD General Market 8 10689 06186 1 997 6192 00LF LX1251TI ...

Page 6: ...ons 1 Backlight control 2 Backlight Control 3 LED Green When video present Amber when there is no video signal present and the monitor will go into standby mode LED remains Amber in Standby Mode Off no power to display 4 Power Switch Pass through for remote PC shutdown N O SPST switches not Monitor Power an external device 1 2 3 4 ...

Page 7: ...LX1250TI User Manual 7 All mounting strain relief holes M4 x 8 mm ...

Page 8: ...ower power better EMI performance better environmental impact no mercury and to minimize overall monitor depth and weight Hazardous materials compliant for international deployment Features Brightness control allows you to easily adjust the display to match ambient light from full sunlight to nigh Even while wearing gloves The convenient buttons enable quick adjustments The monitor s optically bon...

Page 9: ...ble on the back of the display enclosure see page 31 4 Connecting the monitor to the computer and power source see page 17 Note The touch sensor is factory tested calibrated however different computing environments may require the touch screen to be recalibrated Windows Linux tools can be downloaded at For Windows Support http www irtouch com shtml 20091124180041 shtml For Linux Support http www i...

Page 10: ...ch response and accuracy a If Touch alignment is reversed install Touch calibration tools NOTE Touch screen is calibrated at factory Some computer interfaces may require recalibration at installation Regular Calibration is not required 7 Once monitor is verified working with PC proceed to mechanical installation Mechanical Installation Display may be mounted in several configurations a Panel mount...

Page 11: ...n 3 To move the cursor touch the screen and move the cursor as needed Using Remote OSD features This is an advanced feature and should only be attempted by qualified individuals The display allows for remote PC management The display is controlled via the USB interface The controlling PC requires a virtual COM port to operate the display Drivers for the Display Virtual comport can be found here ht...

Page 12: ...LX1250TI User Manual 12 ...

Page 13: ...intain any static self generated images such as a no video text box when video is not present thus avoiding image burn in 2 1 2 Details of Command Implementation All serial commands must be compatible with the Pixel works PW Host protocol defined in the Pixel works application note AN 77 Refer to AN 77 for protocol details The physical layer used for data exchange is RS232 No handshaking is used P...

Page 14: ...LX1250TI User Manual 14 ...

Page 15: ...LX1250TI User Manual 15 ...

Page 16: ...LX1250TI User Manual 16 ...

Page 17: ...LX1250TI User Manual 17 ...

Page 18: ...LX1250TI User Manual 18 ...

Page 19: ...LX1250TI User Manual 19 ...

Page 20: ...LX1250TI User Manual 20 ...

Page 21: ...LX1250TI User Manual 21 ...

Page 22: ...LX1250TI User Manual 22 ...

Page 23: ...LX1250TI User Manual 23 Troubleshooting the Monitor ...

Page 24: ...ing properly and has not entered power saving mode You may also want to disable the computers power saving feature Problem Partial image or incorrectly displayed image Make sure the computer s image resolution is set to one of these resolutions 1024 x 768 XGA 800 x 600 SVGA or 640 x 480 VGA Problem Image is scrolling Check and make sure the VGA signal cable or adapter is securely connected at both...

Page 25: ... operate normally while being cleaned in a fashion normal for a transportation environment This includes cleaning with a damp wrung out mild soapy cloth The LX1250TI will withstand cleaning solutions used in transportation Possible chemicals include 70 isopropyl alcohol 1 6 aqueous ammonia Formula 409 Fantastic Cooling Cooling will be provided solely by convection cooling no fan Functional Specifi...

Page 26: ...rightness of the backlight LED status light The Monitor shall have a single LED for video status LED green The LED Shall be green with there is video present LED amber The LED shall be amber when there is no video signal present and the monitor will go into standby mode Module Specifications This section describes the internal components of this monitor Refer to Block Diagram in the Product Descri...

Page 27: ...tion provides audio warning signals Location Rear of display To use Buzzer Apply a 500hz 1khz 500mv 1V sign wave to the Audio Input signals Duration of the signal controls perceived volume 1ms minimum 1khz 2ms minimum 500hz Mechanical enclosure Function provides support for internal components and EMI cage Rugged Material Aluminum Designed for IP67 Powder coated enclosure Front Bezel Material Alum...

Page 28: ... Backlight 27 USB downstream 13 RX0 33 USB 28 USB power downstream 9 RXC 32 USB 21 USB gnd downstream 15 RXC 22 USB power 18 VGA blue 7 Gnd Logic 1 37 USB GND 6 VGA Green 5 Gnd Logic 2 8 VGA red 14 Gnd Logic 3 5 7 1 I O Connectors LX1251TI Power Manufacture LTW Part number LTWCD 07MMS LC7001 and mating LTWCD 07BFFA LL7001 Description 7 pin IP 68 rated locking Reference Planar mating cable PN Or LT...

Page 29: ...n 300 High ambient contrast Per Mil Std 85762A Greater than 7 1 at 8000 fc Measured CR or 11 1 with daylight diffused at 8 000 fC CR or 3 5 for glare source of 2000 fL measured at 30 to normal Voltage Range 8 to 32 V 12 V nominal Pin Description Pin Description Pin Description Power 5 GND USB 1 Blue 8 30VDC To Inverter 6 Red GND 5 Shield 2 Orange Ground To Inverter 7 Green GND 4 Black 3 Yellow 8 3...

Page 30: ...all have reverse polarity protection as long as there is a slow blow fuse for power 12 V use fuse 2A 24 V use fuse 1A Maximum Power Consumption Maximum 10 W 12 or 24V Typical power consumption 7 7W 12 or 24V Power consumption in standby Power LED amber 2 5 W 12 or 24V typical Mechanical Outline Preliminary dimensions Figure 2 Outline Drawing ...

Page 31: ...rvice BOM provided on request Environmental Specifications Temperature Operating Temperature 20 C to 60 C 4 to 140 F Storage Temperature 20 C to 85 C 4 to 185 F Operating Survival Temp Range 40 C to 70 C Humidity Operating MIL STD 810F 95 RH with 20 to 60 C temperature cycle for 11 days Altitude Operating 15K ft IEC 60068 PT2 13 4hr Non operating 30K ft IEC 60068 PT2 13 4 hr Vibration Note Tests p...

Page 32: ... IEC 61000 4 4 2004 Electrical Fast Transient Burst Immunity Test IEC 61000 4 5 2005 Surge immunity test IEC 61000 4 6 2008 Immunity to conducted disturbances induced by radio frequency fields IEC 61000 4 8 2001 Power frequency magnetic field immunity test IEC 61000 4 11 2004 Voltage Dips Short Interruptions and Voltage Variations Immunity Tests Safety Must be certified to comply with the followin...

Page 33: ... demonstrated by test or calculation excluding brightness degradation Included in the Shipping Box LX01250TI touch monitor Shipping Configuration State of monitor when shipped The unit will be shipped in the ON state Brightness Control Set to Maximum Product accessories Upon customer request ...

Page 34: ... Typical contrast ratio 10 1 70 70 H 60 60 V Response Time Typical 25 ms Brightness Typical 650 cd m Min Display Resolution XGA Refresh Rate 60 to 68 Hz Preliminary Dimensions 12 5 W x 10 H x 2 3 D no connectors Preliminary Display Weight 5 5lbs 2 5kg Audio input Mono 0 1VPP LX1250TI only External Connections 37 pin Military connector Power Supply None provided Power Requirements 8 32 V DC Power C...

Page 35: ...LX1250TI User Manual 35 020 1121 00 A ...