11. If the Invitium system has been exposed to liquid, has been dropped, or if its casing has

been damaged, it may pose a shock or fire hazard. Immediately unplug it and contact cus-
tomer service for assistance.

12. Use only the power adapter that has been tested and approved for use with this product.
13. Use and maintain the safety ground plug set (power cord) included with the unit.
14. After you have installed the Invitium system, secure all electrical cords to prevent the unit

from being pulled off the table or other accidental damage.

15. The Invitium computer system, its power supply and its optional battery pack meet the

UL 2601 standard for cleaning in a hospital environment. Please see the upcoming section
on Cleaning for details.

16. Before cleaning, or if the unit becomes wet for any reason, it is best to disconnect the unit

from its power source.

17. Practice caution when moving the Invitium system to a different location. Use original

packaging whenever possible.

The Invitium system must be plugged into a GROUNDED power outlet.

1.5  —  Cleaning

The Invitium Medical Workstation continues to operate normally while being cleaned in a
fashion normal for a hospital environment.This includes cleaning with a damp, mildly soapy
cloth. Drip protection is provided in accordance with IPX1 rating defined in the
IEC/EN60529 standard.

The Invitium system can withstand cleaning solutions used in hospitals for similar equipment.
This is typically warm water and mild detergent for all surfaces, or 70 percent IPA for the
touchscreen surface. Possible chemicals include:

• 70% isopropyl alcohol
• 1.6% aqueous ammonia
• Cidex‚ (2.4% glutaraldehyde solution)
• Sodium Hypochlorite (bleach) 10%
• “Green  soap” USP
• 0.5% Chlorhexidine in 70% isopropyl alcohol
• Ovation

®

• Formula 409

®

• Fantastic

®

• WexCide

®

To clean the Invitium monitor screen, do not spray liquid cleaners directly onto it. Stand away
from the monitor and spray the cleaning solution onto a nonabrasive cloth. Clean the screen
with the slightly dampened cloth, without applying excessive pressure.

1.6  —  Service support 

The Invitium Medical Workstation requires no routine maintenance.There are no user-serviceable
components inside it. If repair is required, please return the unit to Planar Systems for servicing to
maintain the product warranty. See details in the Warranty section in the opening pages of this
manual.

S E C T I O N

1 :

Overview

5

Invitium Manual LAYOUT  3/26/02  9:35 AM  Page 5

Summary of Contents for invitium

Page 1: ...OPERATIONS MANUAL...

Page 2: ...Invitium Medical Workstation OPERATIONS MANUAL Copyright 2002 Planar Systems Inc...

Page 3: ...ay not be reproduced stored in a retrieval system or transmitted by any means without prior written permission of Planar Systems Inc Invitium is a trademark and Planar is a registered trademark of Pla...

Page 4: ...plaining its features and key specifica tions Section 2 Getting Started includes instructions on mounting the Invitium workstation and connecting its modules making display adjustments and calibrating...

Page 5: ...responsible for compliance could void the user s authority to operate the equipment Canadian Doc Notice For Class B Computing Devices This digital apparatus does not exceed the Class B limits for radi...

Page 6: ...upply alone does not represent a functional medical device Hence Planar configured a minimal operating system to exercise the display The resulting data is made available to interested parties The dat...

Page 7: ...em should assure that it is used in such an environment EMISSIONS TEST COMPLIANCE ELECTROMAGNETIC ENVIRONMENT GUIDANCE RF emissions The Invitium System uses RF energy only for its CISPR 11 Group 1 int...

Page 8: ...f a typical commercial or hospital environment Surge IEC 61000 4 5 1KV differential mode 2KV common mode 1KV 2KV Mains power quality should be that of a typical commercial or hospital environment If t...

Page 9: ...han the compliance level in each fre quency range b Interference may occur in the vicinity of equipment marked with the following symbol Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3Vrms 150...

Page 10: ...rmonized standards published in the official journal of the European Communities Indicates that the product has been tested and certified with respect to electric shock fire mechanical and other speci...

Page 11: ...turned to its original configuration before any warranty service will be performed by Planar No goods are to be returned to Planar without prior authorization Buyer will be responsible for packaging a...

Page 12: ...r person s rendering of technical advice assistance or services in connection with the buyer s order of the good fur nished hereunder The Buyer is not relaying on Planar s skill or judgment to select...

Page 13: ...xii Invitium Medical Workstation O P E R AT I O N S M A N U A L...

Page 14: ...the monitor to the computer 15 Starting up the Invitium workstation 16 Adjusting monitor controls 16 Using a floppy drive 17 Calibrating the Invitium Workstation Touchscreen 18 Non touchscreen systems...

Page 15: ...nformation messages 41 Resetting the Invitium system 41 Reinstalling Windows and Drivers 42 Windows 2000 installation procedure 44 Touchscreen driver installation 45 Technical Specifications Environme...

Page 16: ...om the box please contact us in the U S at 866 475 2627 or 503 748 1100 or in Finland at 358 9 42001 Optional equipment and parts will be shipped separately 1 1 About the Planar Invitium Medical Works...

Page 17: ...e external power supply or by an optional battery pack Each provides a regulated 12 volts as the main system voltage The computer and monitor can be mounted together to form a single integrated unit o...

Page 18: ...supply is equipped with an IEC320 appliance coupler The power adapter includes an attached power cable that terminates in the required monitor power connector An LED indicates when power is applied A...

Page 19: ...intended for direct connection to the patient 1 4 Safety Instructions The Invitium Medical Workstation is designed to ensure both the highest level of product quality and safety for the user To mainta...

Page 20: ...continues to operate normally while being cleaned in a fashion normal for a hospital environment This includes cleaning with a damp mildly soapy cloth Drip protection is provided in accordance with I...

Page 21: ...6 Invitium Medical Workstation O P E R AT I O N S M A N U A L...

Page 22: ...c All other trademarks are the properties of their respective owners Planar Systems Inc 1400 N W Compton Drive Beaverton OR 97006 USA Phone 866 475 2627 503 748 1100 Fax 503 748 1493 Planar Systems In...

Reviews: