18
c) 256 MB RAM;
d) 25 MB of hard drive free space for software and additional space for database (depends on
device running time, number of connected devices and quantity of measurements);
e) network interface controller supporting the operation in Ethernet network;
f) SVGA monitor and video card (256 colors and 1024x768 pixel resolution);
g) mouse.
3.4.3. Software Installation
Installation of the required software is executed by
Setup_ViewRSA_2.1.3.exe
program
(program software version can be different), which performs the procedure of installing
ViewRSA
software to the computer hard drive.
•
Before installation, close all active applications and log in as administrator.
•
If you are using CD for installation, place it into the disk drive. After the disk is loaded, find
Setup_ViewRSA_2.1.3.exe
file and run it. If you received the software in some different
way, just run
Setup_ViewRSA_2.1.3.exe
.
•
After you have started the installation program, the installation wizard window will appear.
Click
Next
to initialize installation.
•
Then select the folder where you would like to save the program files. By default, the files
are saved into
C:\Program Files\PLANAR\ViewRSA
. To save the files into a different
folder, click
Browse
. Select the required path and click
OK
.
•
The following steps will be fulfilled automatically. If the installation is correct, the information
window indicating successful installation will appear on the screen. Click
Finish
to complete
the installation.
After the installation has been completed, the
ViewRSA
folder
containing a shortcut for
accessing the program will be created in the Windows
Start
menu.
3.5. Operating Analyzer via SNMP Protocol
3.5.1. General Information
CIU-003 TV Signal Analyzer supports the
SNMPv1
communication protocol and can be
connected to third-pary monitoring systems, which use this protocol. Follow the procedure below to
connect the Analyzer to monitoring system:
a)
include the MIB-file of CIU-003 Analyzer into the monitoring system. You can find it on CD
included into the Analyzer package. Also you can download this file from our web-site
www.planar.chel.ru
.
b)
add the Analyzer to the monitoring system. You should set the following parameters of
SNMP protocol:
- communication
protocol:
SNMPv1
;
- SNMP protocol port:
161
;
- port for trap reception:
162
;
- read
password:
public
;
- write
password:
public
.
c)
make sure the Analyzer is working correctly by viewing one of the standard nodes of MIB-
2 tree;
d)
configure the IP addresses of trap recipients (see Section 3.5.2);
e)
restart the Analyzer and make sure the SNMP-manager
received the
Coldstart
trap.