Safety Information

General Instructions

The device should only be operated according to the specifications in the instruction manual. The
requisite Health & Safety regulations for a given application must also be observed. This also aplies
to the use of accessories.

Proper Usage

The pressure transmitter PUM04 and PUM06 are designed to measure the relative and absolute
pressure of gaseous and liquid media which do not attack the device materials. All other usage is re-
garded as being improper and outside the scope of the device. 

The series PUM04 and PUM06 devices should not be deployed as the sole agents to prevent danger-
ous conditions occurring in plant or machinery. Machinery and plant need to be designed so that
faulty conditions do not arise that could pose a safety risk for operators.

Dangerous substances

For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as well as
refrigeration   systems,   compressors,   etc.   must   comply   with   the   relevant   regulations   beyond   the
general rules. 

Qualified Personnel

PUM04 and PUM06 devices may only be installed by trained, qualified personnel who are able to
mount the devices correctly. Qualified personnel are persons, who are familiar with assembling, in-
stallation, placing in service and operating these devices and who are suitably trained and qualified.

PUM04, PUM06 Instruction manual  12/2017

page  2

Summary of Contents for PUM04

Page 1: ...truction Manual PUM04 PUM06 Pressure transmitter of stainless steel PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp...

Page 2: ...ed as the sole agents to prevent danger ous conditions occurring in plant or machinery Machinery and plant need to be designed so that faulty conditions do not arise that could pose a safety risk for...

Page 3: ...adiation heat The mounting position which the transmitter is adjusted for is indicated on the rating plate If the device is installed in a different position the zero point may be offset In this case...

Page 4: ...ront flush membrane Connecton for front flush membrane up to measuring range R78 0 25 bar from measuring range R79 0 40 bar and for all ranges of PUM04 Socket Connector PUM04 PUM06 Instruction manual...

Page 5: ...g plate Significance of applied terminal designations supply voltage Ub Ub output signal S S cable shield case earth shield PE Current output Voltage output Output signal 4 20 mA 2 wire system Output...

Page 6: ...d on the site Repairs can only be carried out at the factory Depending on working conditions the pressure transmitters should be checked about once a year to ensure that they are within their specific...

Page 7: ...ly placed between the transmitter and the plug and displays the measured value without additional supply voltage Typical applications The robust design of the PUM04 pressure transmitter offers the use...

Page 8: ...G 3 4 B male thread front flush membrane 3 G 1 4 female thread inside membrane 9 special connection please specify in plain text Measuring range Overrange limit R16 1 0 bar 2 0 bar not at PUM04 S R69...

Page 9: ...hese two techniques covers all DIN measuring ranges from 1 0 bar to 0 2500 bar with constant accuracy Typical applications The robust design of the PUM06 pressure transmitter offers the user the abili...

Page 10: ...R13 0 25 0 bar 0 6 bar R14 0 4 0 bar 2 0 bar R15 0 6 0 bar 2 0 bar R16 1 0 bar 2 0 bar R43 1 1 5 bar 4 bar R45 1 5 bar 13 bar R63 0 0 1 bar 0 6 bar R64 0 0 16 bar 0 6 bar R65 0 0 25 bar 0 6 bar A65 0...

Reviews: