Flow Measurement and Monitoring

FOS01

Optoelectronic
Level Switch

for liquids

small and compact, no mechanics

easy installation 

switching status indication by LED

low maintenance

max. pressure: 50 bar

max. temperature: 135 °C

Description:

An   optical   sensor   is   mounted   in   a   robust   stainless   steel
housing. It consists of a quartz glass tip with an infrared diode
as transmitter and a light-sensitive semiconductor as receiver.
If no liquid wets the sensor tip, the infrared light is completely
reflected from the inside of the quartz glass. 
However, as soon as it is immersed in the medium, a large
part of the transmitted light can be escape into the liquid. This
is registered by the receiver, which then initiates a switching
process at the PNP transistor output of the device, which is
indicated directly by a green LED.

Typical applications:

The field of application for optoelectronic level indicators is the
detection   of   limit   values   in   a   large   number   of   liquids.   The
advantage   here   is   that   the   measurement   method   is   largely
independent   of   physical   variables   such   as   refractive   index,
color,   density,   dielectric   constant   or   conductivity.   The   very
compact   design   guarantees   minimal   space   requirements,
making   measurement   in   very   small   volumes   possible.   The
arbitrary mounting position as well as the high pressure and
temperature ranges offer a wide range of applications.

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

20190907

Summary of Contents for FOS01

Page 1: ...PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de Instruction Manual FOS01 Optoelectronic Levelswitch...

Page 2: ...afety 5 3 Specifications 9 4 Design and function 10 5 Transport packaging and storage 11 6 Commissioning operation 12 7 Maintenance and cleaning 13 8 Faults 14 9 Warranty 15 10 Dismounting return and...

Page 3: ...led personnel at any time Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work The manufacturer s liability is void in the case of any damag...

Page 4: ...vance can result in serious injury and or damage to equipment Further important safety instructions can be found in the individual chapters of these operating instructions 2 1 Intended use This instru...

Page 5: ...egulations current standards and directives are capable of carrying out the work described and independently recognising potential hazards Special operating conditions require further appropriate know...

Page 6: ...ening voltages on the instrument WARNING Residual media in dismounted instruments may result in a risk to people the environment and the system Take sufficient precautionary measures Do not use this i...

Page 7: ...awings Materials Sensor Tip Electronics housing Stainless steel 1 4571 Quartz Stainless steel 1 4301 Electrical Data Supply voltage DC 24 V 25 30 Supply current max 40 mA Power consumption 1 W Output...

Page 8: ...conductance and dielectric constant of the liquid Integrated electronics include limit sensing and self calibration The output is an open collector pnp transistor 4 2 Instrument design The sensor is...

Page 9: ...on mechanical shock putting it down hard Soot vapour dust and corrosive gases Potentially explosive environments flammable atmospheres Store the instrument in its original packaging in a location that...

Page 10: ...hen withdrawn from a glass of water WARNING The electrical connection must only be carried out by qualified skilled personnel Observe the relevant VDE regulations 6 1 Installation instructions tank or...

Page 11: ...reen white O C pnp Load Switching direction The switching direction is factory set Model Function Condition LED Output transistor Ext relay SE Normally open immersed on switch on connect SE Normally o...

Page 12: ...nstrument see chapter 10 2 Return 8 Faults Faults Possible causes Measures No function No power supply Measure power supply check connection to cable or plug No function in spite of liquid level chang...

Page 13: ...depressurised 10 2 Return WARNING Absolutely observe when shipping the instrument All instruments delivered to PKP Prozessmesstechnik GmbH must be free from any kind of hazardous substances acids base...

Page 14: ...uid This is registered by the receiver which then initiates a switching process at the PNP transistor output of the device which is indicated directly by a green LED Typical applications The field of...

Page 15: ...Min distance to an opposite surface 10 mm 20 mm if electropolished Mounting position any Dimensions Order Code Order number FOS01 Optoelectronic level switch 3 2 1 1 0 Process connection 1 M16 x 1 5 2...

Reviews: