Model (table. 1):

Depending on the field of applications and media properties, 
the DV04 available in 6 different models:

Model

Material

Min.

viscosity

[mm²/s]

Accuracy [%
of measured

value]

Media properties

Viscosity Lubricating

properties

1

GJS-

400/600

20

± 0,3

low

good

2

GJS-400

50

± 0,5

intermediate

good

4

GJS-400

100

± 0,5

intermediate

low

5

st. steel 

1.4404

100

± 0,5

DV04.2: ± 3

intermediate

low

6

st. steel 

1.4404

20

± 0,3

low

good

8

st. steel 

1.4404

20

± 1

low

low

Process connection (table. 2):

Model

1

2

4

5

6

8

MB-Code

Ball

bearing

Ball

bearing

Carbide

plain

bearing

Carbide

plain

bearing

Ball

bearing

Hybrid

ball

bearing

DV04.2

G 3/8

-

-

G 1/8

G 1/8

G 1/8

DV04.3

G 3/8

-

-

-

G 1/4

G 1/4

DV04.3A

G 3/8

-

G 3/8

-

G 3/8

G 3/8

DV04.4

G 3/8

G 3/8

G 3/8

G 3/8

G 3/8

G 3/8

DV04.5

G 1/2 or 

G 3/4

-

G 1/2 or 

G 3/4

-

-

-

DV04.6

G 1/2 or 

G 3/4

G 1/2 or 

G 3/4

G 1/2 or 

G 3/4

G 1/2 

G 1/2 

G 1/2 

DV04.7

G 1

G 1

G 1

G 1

G 1

-

DV04.8

G 1

G 1

G 1

G 1

G 1

-

DV04.9

SAE*

)

-

-

-

-

-

DV04.10

SAE*

)

-

-

-

-

-

*

)

SAE flange, d = 38 mm

Measuring ranges [l/min] (Tab. 3):

MB-
Code 

Model

1

2

4

5

6

8

DV04.2

0,008-2

-

-

0,02-2

0,008-2

0,008-2

DV04.3

0,02-4

-

-

-

0,02-4

0,02-4

DV04.3A

0,04-8

-

0,04-8

-

0,04-8

0,04-8

DV04.4

0,16-16

0,16-16

0,16-16

0,16-16

0,16-16

0,16-16

DV04.5

0,2-40

-

0,2-30

-

-

-

DV04.6

0,4-80

0,4-80

0,3-60

0,3-60

0,4-80

0,4-80

DV04.7

0,6-160

-

0,6-100

0,6-100

0,6-160

-

DV04.8

1-250

1-250

1-160

1-160

1-250

-

DV04.9

2-600

-

-

-

-

-

DV04.10

3-700

-

-

-

-

-

Parameters (Tab. 4):

MB-Code

Max. pressure [bar]

Sound pressure

level [dB(A)]

Resolution [Imp./l]

DV04.2

480

< 65

40.000

DV04.3

480

< 65

25.000

DV04.3A

480

< 65

10.000

DV04.4

480

< 65

4.081,63

DV04.5

480

< 65

2.500

DV04.6

480

< 65

965,25

DV04.7

350

< 65

333,33

DV04.8

350

< 65

191,5

DV04.9

480

< 65

83,33

DV04.10

480

< 65

62,5

Order Code:

Order number:            DV04.

Gear wheel counter

2. 1. F. PS. 10. S. 0. 0

Measuring ranges:

2…10

= see table 3

Model:

1…8

= see table 1

Gasket:

F  = FKM (standard)
E  = EPDM
P  = FEP
K  = FFKM

Connection type:

PS  = with mounting plate, connection at side

(standard, not for models 5, 6, 8)

PU  = with mounting plate, connection bottom 

(not for models 5, 6, 8)

R  = without mounting plate, connection at side

   (models 5, 6, 8 only)

Process connection: (see table 2)

04  = G 1/8 female thread
06  = G 1/4 female thread
10  = G 3/8 female thread
15  = G 1/2 female thread
20  = G 3/4 female thread
25  = G 1 female thread
40  = SAE flange, d = 38 mm

Electronic version:

S  = standard
H1  = high temperature version up to 150 °C
H2  = high temperature version up to 210 °C (FEP gasket

   and terminal box)

X  = intrinsically safe with separate switching amplifier 

   (EEx ia IIC)

Display:

0

= without display

DVA= prepared for plug-on display DVA

   (date sheet on the following pages)

Options:

0  = without
1  = please specify in plain text

(*not for models 5, 6, 8)

Technical Data:

Viscosity range: 

20…100.000 mm²/s

Pressure drop: 

depending on viscosity and
load of the devices
(exact values on request)

Medium temperature range:

s

tandard version: 

−40 °C…+120 °C

high temp. version: 

−30 °C…+150 °C, (210 °C)

Materials:

models

 1, 2, 4:

 

housing GJS-400-15,
GJS-600 (DV04.9, DV04.10)
measuring unit steel 1.7139

models

 5, 6, 8: 

housing st. steel 1.4404
measuring unit st. steel 1.4462

Electronic:

s

tandard: 

2 sensors, 90° phase-shifted

Ex-version: 

with separate switching amplifier

Power supply: 

12…30 VDC,
protected against polarity reversal

Power consumption:

0,9 W

Output signal: 

square-wave pulses, min. 0,8 x UB,
duty cycle 1:1 (± 15 %)

Protection class: 

IP65

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

Fl

ow

Summary of Contents for DV04 Series

Page 1: ...Manual DV04 High precision gear wheel counter for viscous liquids PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de...

Page 2: ...prevention and environmental protection regulations generally valid for the work area must be observed The liability of the manufacturer expires in the event of damage due to improper use non observan...

Page 3: ...the accompanying delivery note the number of parts must be checked Claims for replacement or goods which relate to transport damage can only be considered valid if the delivery company is notified wi...

Page 4: ...d not be subject to excessive vibration Only genuine spare parts must be used for service and maintenance Corrosion Protection All gearwheel flow meters are checked for proper function at the factory...

Page 5: ...eing exceeded in the volume sensor or other parts of the installation pressure limiting valves During transport and installation the gearwheel flow meter must only be held by its housing must never be...

Page 6: ...nnection plate 4 tighten all fastening screws crosswise to the prescribed torque Make sure that the product is not distorted Ensure sufficient screw in depth of the fastening screws 1 fastening screws...

Page 7: ...earwheels and thus on the preceding sign or that is used when dis playing the measured volumetric flow rate on the evaluation device Number of measuring channels 2 Operating voltage UB 24 VDC 20 prote...

Page 8: ...m of the device Adjust pressure relief valves in the system installed for lowest opening pressure Run the device for a few minutes depressurised or with low pressure Vent the system at the highest pos...

Page 9: ...gearwheel meter and the piping system must be checked regularly for leakage Removal 1 Depressurise and de energize the system 2 Close existing shut off elements upstream and downstream of the device...

Page 10: ...of the gearwheel flow meter do not pry the halves apart at the joint with screwdrivers or similar tools The gearwheels must not be removed from the housing with pliers or similar tools Clean the inter...

Page 11: ...easuring unit is blocked Put the device out of operation immediately Send devices of model 1 2 6 and 8 to manufacturer to be repaired Devices of model 4 and 5 can be cleaned by user Seal failure Leaka...

Page 12: ...8 DV04 3 85 9 60 56 107 70 40 20 6 7 M 6 14 2 0 DV04 4 85 13 60 57 108 70 40 20 9 M 6 14 2 0 DV04 5 100 17 90 63 114 80 38 34 16 M 8 35 3 7 DV04 6 120 13 95 72 123 15 5 84 72 35 16 M 8 35 5 2 DV04 7 1...

Page 13: ...C ATEX Type dimensions mm torque Nm weight A C D F G J K L M N P MA kg DV04 9 44 249 168 219 78 120 140 70 38 M 20 400 53 5 DV04 10 38 249 184 235 78 120 140 70 38 M 20 400 57 4 plus 12 mm for electro...

Page 14: ...60 50 87 70 40 20 6 7 M 6 14 1 8 DV04 3 85 9 60 56 93 70 40 20 6 7 M 6 14 2 0 DV04 4 85 13 60 57 94 70 40 20 9 M 6 14 2 0 DV04 5 100 17 90 63 100 80 38 34 16 M 8 35 3 7 DV04 6 120 13 95 72 109 18 5 8...

Page 15: ...04 3 9 94 56 107 70 40 20 6 7 M 6 14 3 DV04 4 13 94 57 108 70 40 20 9 M 6 14 3 1 DV04 5 17 118 63 114 80 38 34 16 M 8 35 4 8 DV04 6 13 124 72 123 15 5 84 72 35 16 M 8 35 7 DV04 7 18 170 89 140 46 5 46...

Page 16: ...94 90 56 107 15 70 40 6 7 3 DV04 4 G 3 8 13 25 94 90 57 108 16 70 40 6 5 3 1 DV04 5 G 1 2 15 29 118 114 63 114 17 5 80 38 9 4 8 DV04 6 G 1 2 15 29 124 120 72 123 22 15 5 84 72 9 7 DV04 7 G 1 19 51 5...

Page 17: ...7 11 7 70 40 20 6 5 M6 17 0 7 25 13 1 8 DV04 5 G 1 2 100 110 37 86 96 7 11 7 80 38 34 16 M8 18 5 0 7 29 15 2 7 DV04 6 G 1 2 100 120 37 80 106 7 11 7 84 72 35 12 M8 17 5 0 7 29 15 2 9 DV04 7 G 1 100 1...

Page 18: ...the measuring chamber and phase shifted by 90 This two channel scanning enables a higher measured value resolution as well as the detection of the flow direction by means of suitable electronics As a...

Page 19: ...350 65 191 5 DV04 9 480 65 83 33 DV04 10 480 65 62 5 Order Code Order number DV04 Gear wheel counter 2 1 F PS 10 S 0 0 Measuring ranges 2 10 see table 3 Model 1 8 see table 1 Gasket F FKM standard E...