PKP DV01 Instruction Manual Download Page 2

Table of Contents

Safety Information..................................................................................................................2
General Information...............................................................................................................3
Functional Description...........................................................................................................3
Installation and Removal........................................................................................................4

Commissioning

.......................................................................................................................5

Pipe and Plate Connection....................................................................................................5
Tightening Torques for the Connection Plates......................................................................5
Maintenance and Filtration....................................................................................................6
Return Shipment....................................................................................................................6
Electrical Connection.............................................................................................................6

Safety Information

General Instructions

To ensure safe operation, the device should only be operated according to the specifica -
tions   in   the   instruction   manual.   The   requisite   Health   &   Safety   regulations   for   a   given
application must also be observed. This statement also applies to the use of accessories.
Every person who is commissioned with the initiation or operation of this device must have
read and understood the operating instructions and in particular the safety instructions! 

The liability of the manufacturer expires in the event of damage due to improper use, non-
observance of this operating manual, use of insufficiently qualified personnel and unau-
thorized modification of the device. 

Proper Usage

The float-type flow meters DS10 are designed to monitor continuous flow rates of liquids
or gases which do not attack the device materials. All other usage is regarded as being
improper and outside the scope of the device. 

In   particular,   applications   in   which   shock   loads   occur   (for   example,   pulsed   operation)
should be discussed and checked in advance with our technical staff.

The gear wheel flow sensors of the DV01 series are characterised by reliable function and
simple operation. The devices of the DV01 series are mainly used for consumption meas-
urements and for the control of filling processes as well as for lubrication point monitoring.
Machinery and plant need to be designed in such a manner that faulty conditions and mal-
functions do not arise that could pose a safety risk for operators.

Dangerous substances

For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as
well as refrigeration systems, compressors, etc. must comply with the relevant regulations
beyond the general rules. 

DV01 Instruction manual  09/2019

page  2

Summary of Contents for DV01

Page 1: ...Instruction Manual DV01 Gear wheel flow sensor for viscous liquids PKP Prozessmesstechnik GmbH Borsigstraße 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de ...

Page 2: ...sonnel and unau thorized modification of the device Proper Usage The float type flow meters DS10 are designed to monitor continuous flow rates of liquids or gases which do not attack the device materials All other usage is regarded as being improper and outside the scope of the device In particular applications in which shock loads occur for example pulsed operation should be discussed and checked...

Page 3: ...idered valid if the delivery company is notified without delay General Information Please observe all instructions in this operating manual to ensure trouble free operation of the flow sensors PKP accepts no liability for damage caused by non compliance with these instructions The devices my only be opened within the warranty period after consultation and approval by PKP Functional Description Ins...

Page 4: ... built in meter should be accessible for visual inspection at any time during operation Attention In the event of damage to the gear wheel flow meter a pressure safety device must be provided in the system to prevent the maximum permissible pressure of the volume sensor or other components in the system from being exceeded pressure relief valves It must be ensured that the flow meters are only hel...

Page 5: ...n the piping system before installing the gear wheel flow meter Connect the piping to the inlet and outlet of the meter Follow the instructions of the respective manufacturer During installation make sure that no sealant enters the inside of the pipes Attention The gear wheel flow meter must not be braced during installation After commissioning the system check all connections for leaks Plate conn...

Page 6: ...y or very high loads This avoids major damage which could be causes for example by blocking the bearings Return Shipment When returning devices to the factory please note that inspections and repairs will only be carried out if a safety data sheet of the medium used is enclosed and the devices have been flushed beforehand In case of non observance the goods will be returned carriage forward These ...

Page 7: ...al and axial plain bearings in the case of the DV01 1 and DV01 3 the DV01 2 uses ball bearings A magneto resistive measuring system hermetically sealed from the measuring chamber senses the rotation of the gear wheels and converts it into a pulse train The gear wheel flow meter DV01 causes a very low pressure drop and makes especially little noise Typical applications The gear wheel flow meters DV...

Page 8: ...m DV01 3A b 90 mm t 100 mm h 73 mm DV01 4A b 120 mm t 170 mm h 105 mm Order Code Order number DV01 Gear wheel flow sensor 1A 0 0 Measuring ranges 0A 0 02 4 l min aluminium 0E 0 02 4l min stainless steel 1A 0 25 10 l min aluminium 1E 0 25 10 l min stainless steel 2A 0 16 16 l min aluminium 3A 1 65 l min aluminium 4A 1 200 l min aluminium Display 0 without display DVA prepared for plug on display DV...