Table of Contents
Safety Information..................................................................................................................2
Overview................................................................................................................................4
Installation..............................................................................................................................5
Connecting devices equipped with Reed switches................................................................7
Electrical connection..............................................................................................................9
Contacts for DS02.1 / DS02.2:............................................................................................10
Contacts for DS02.2 / DS02.3 / DS02.4..............................................................................12
Setting the switch point........................................................................................................14
Troubleshooting guide.........................................................................................................15
Maintenance / Maintenance plan.........................................................................................16
Degree of protection (IP-Code)............................................................................................16
Returns.................................................................................................................................16
Safety Information
General Instructions
To ensure safe operation, the device should only be operated according to the specifica -
tions in the instruction manual. The requisite Health & Safety regulations for a given
application must also be observed. This statement also applies to the use of accessories.
Every person who is commissioned with the initiation or operation of this device must have
read and understood the operating instructions and in particular the safety instructions!
The liability of the manufacturer expires in the event of damage due to improper use, non-
observance of this operating manual, use of insufficiently qualified personnel and unau-
thorized modification of the device.
Proper Usage
The variable area flowmeters of the DS02 series are used exclusively for monitoring and
indicating continuous flows of gaseous and liquid media that do not attack the materials
used. All other usage is regarded as being improper and outside the scope of the device.
Max. Pressure:
DS02.1
DS02.2
DS02.3/4
Liquids:
200 bar (brass)
300 bar (VA)
300 bar (brass)
350 bar (VA)
300 bar (brass)
350 bar (VA)
Gases:
300 bar (brass)
350 bar (VA)
300 bar (brass)
350 bar (VA)
250 bar (brass)
300 bar (VA)
Pressure loss:
DS02.1: 0,02–0,2 bar
DS02.2: 0,02–0,3 bar
DS02./4: 0,02–0,4 bar