background image

Flow Measurement and Monitoring

DG06

Sight Flow Indicator
with Flap and Scale

for liquids

robust design

cast steel or stainless steel
version

for nominal sizes from 1/4“ to 4“ ,
with threaded fitting or flange

available with PN 16 or PN 40
pressure ratings

externally attached numerical scale
indicates approximate flow volume

max. temperature: 250 °C

Description:

The DG06 flow indicator allows visual and quantitative moni-
toring 

of liquid flows. The device has two large glass panes –

one on each side – and each with a scale attached.

A stainless steel flap mounted in the flow chamber is lifted
when there is flow and the current flow rate is displayed on
the scale. The flap is mounted on a stainless steel shaft; it is
raised   by   flow   and   lowered   by   gravity.   The   DG06   can   be
installed both horizontally and vertically (with flow from bottom
to top) and deployed in a wide variety of applications – not
least because it is not adversely affected by high tempera-
tures.

Typical applications:

This flow indicator provides visual and quantitative monitoring
of liquids. There is potential for a myriad of applications in the
fields of industrial machinery and process control, as well as
basic monitoring of cooling units etc.

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

20210430

Summary of Contents for DG04

Page 1: ...Instruction Manual DG06 Sight Flow Indicator with flap and scale PKP Prozessmesstechnik GmbH Borsigstraße 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de ...

Page 2: ...ce is prohibited and outside the scope of application In particular applications in which shock loads occur for example pulsed operation should be discussed and checked in advance with our technical staff The devices of the DG06 series should not be used as sole monitoring devices in order to detect or even avoid dangerous operating states in plants and machines The plant or machine itself must be...

Page 3: ...inless steel flap arranged in the flow chamber is lifted by the media flow Attention The DG06 is not a flow meter It only indicates the presence of a flow The numbers on the scale cannot be assigned to a flow value They only serve to indicate a certain flow trend Maintenance and care Due to the small number of moving parts the units require very little maintenance How ever regular functional check...

Page 4: ...ow chamber is lifted when there is flow and the current flow rate is displayed on the scale The flap is mounted on a stainless steel shaft it is raised by flow and lowered by gravity The DG06 can be installed both horizontally and vertically with flow from bottom to top and deployed in a wide variety of applications not least because it is not adversely affected by high tempera tures Typical appli...

Page 5: ...85 3 9 DN 20 3 4 95 140 89 66 1 85 3 9 DN 25 1 95 140 89 66 1 8 3 9 DN 32 1 1 4 120 180 120 89 4 7 1 DN 40 1 1 2 120 180 120 89 3 9 7 DN 50 2 150 220 170 110 9 14 5 DN 80 3 258 160 165 19 5 DN 100 4 258 160 165 23 5 G threaded F flanged Larger nominal sizes on request Order Code Order number DG06 Sight flow indicator with flap and scale S B G 15 0 Materials S cast steel E stainless steel Glass pre...

Reviews: