Safety Information

General Instructions

To ensure safe operation, the device should only be operated according to the specifica -
tions   in   the   instruction   manual.   The   requisite   Health   &   Safety   regulations   for   a   given
application must also be observed. This statement also applies to the use of accessories.
Every person who is commissioned with the initiation or operation of this device must have
read and understood the operating instructions and in particular the safety instructions! 

The liability of the manufacturer expires in the event of damage due to improper use, non-
observance of this operating manual, use of insufficiently qualified personnel and unau-
thorized modification of the device. 

Proper Usage

The devices of the DG06 series are used for the optical control monitoring of liquids. Any
other use of the device is prohibited and outside the scope of application.

In   particular,   applications   in   which   shock   loads   occur   (for   example,   pulsed   operation)
should be discussed and checked in advance with our technical staff.

The devices of the DG06 series should not be used as sole monitoring devices in order to
detect or even avoid dangerous operating states in plants and machines. The plant or
machine itself  must  be planned and constructed in such  a way that  critical  conditions
which pose a danger to man and the environment are excluded from the outset

Dangerous substances

For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as
well as refrigeration systems, compressors, etc. must comply with the relevant regulations
beyond the general rules. 

Qualified Personnel

The devices of the DG06 may only be installed by trained, qualified personnel who are
able to mount the devices correctly. Qualified personnel are persons, who are familiar with
assembling, installation, placing in service and operating these devices and who are suit-
ably trained and qualified.

DG06 Instruction manual  04/2019

page  2

Summary of Contents for DG04

Page 1: ...Instruction Manual DG06 Sight Flow Indicator with flap and scale PKP Prozessmesstechnik GmbH Borsigstraße 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de ...

Page 2: ...ce is prohibited and outside the scope of application In particular applications in which shock loads occur for example pulsed operation should be discussed and checked in advance with our technical staff The devices of the DG06 series should not be used as sole monitoring devices in order to detect or even avoid dangerous operating states in plants and machines The plant or machine itself must be...

Page 3: ...inless steel flap arranged in the flow chamber is lifted by the media flow Attention The DG06 is not a flow meter It only indicates the presence of a flow The numbers on the scale cannot be assigned to a flow value They only serve to indicate a certain flow trend Maintenance and care Due to the small number of moving parts the units require very little maintenance How ever regular functional check...

Page 4: ...ow chamber is lifted when there is flow and the current flow rate is displayed on the scale The flap is mounted on a stainless steel shaft it is raised by flow and lowered by gravity The DG06 can be installed both horizontally and vertically with flow from bottom to top and deployed in a wide variety of applications not least because it is not adversely affected by high tempera tures Typical appli...

Page 5: ...85 3 9 DN 20 3 4 95 140 89 66 1 85 3 9 DN 25 1 95 140 89 66 1 8 3 9 DN 32 1 1 4 120 180 120 89 4 7 1 DN 40 1 1 2 120 180 120 89 3 9 7 DN 50 2 150 220 170 110 9 14 5 DN 80 3 258 160 165 19 5 DN 100 4 258 160 165 23 5 G threaded F flanged Larger nominal sizes on request Order Code Order number DG06 Sight flow indicator with flap and scale S B G 15 0 Materials S cast steel E stainless steel Glass pre...

Reviews: