38
When the socket is not accessible for the user
or a fixed electrical connection
of the appliance is required
, an all-pole disconnecting device must be
incorporated during installation. Disconnecting devices are switches with a
contact opening distance of at least 3 mm. These include LS-switches, fuses and
protectors (EN 30335).
1
Hob connector; protective conductor
2
Mains socket
Connection diagram
Voltage heating elements 230V.
Any kind of connection: the safety
wire must be connected to the
PE terminal.
Recommended
type of
connection lead.
1 For 230 V earthed one-phase
connection, bridges connect 1-
2-3 terminals and 4-5 terminals
Protective ground to
H05VV-F3G6,0
2 For 400/230V earthed two-
phase connection, bridges
connect 2-3 terminals and 4-5
terminals
Protective ground to
H05VV-F4G4,0