88
MALFUNCTION
POSSIBLE CAUSE
MEASURE
The appliance
does not work at
all.
LED does not
work at all.
The plug of the appliance is not
connected to the socket.
The plug has become loose.
The socket is not supplied with
energy.
The fuse is switched off.
Check the
corresponding socket
by connecting it with
another appliance.
Check the fuse.
The voltage is too low.
Compare the data on
the model plate with
the data of your energy
supplier.
Light is on but
motor does not
work
ventilation damper blocked
condenser
defective
motor mounting defective
remove blockage
replace condenser
replace motor
The motor
smells doubtful
motor defective
replace motor
Smear of oil
one-way valve is leaky
connection base chimney-
telescopic chimney is leaky
seal the valve
seal the connection
with a suitable material
Appliance
vibrates
motor not properly fixed
hood not properly fixed
fix motor properly
fix hood properly
Insufficient
extracting
capacity
too much distance hood-hob
too much draught because of
open doors and/or windows
lower position of hood
close the
doors/windows
Light does not
work
illuminate is defective
Contact the after sales
service.
Appliance is
unstable
mounting rail is not firmly fixed
screws are not firmly tightened
fix mounting rail
properly
tighten the screws
If the hood does not work properly and/or you can hear increased operating noise, check the
schedule below:
incorrect dimension of the air duct.
obstruction in the air duct.
the diameter of the air duct from hood to wall-box inclusive should be 150 mm;
otherwise the capacity of the motor may be decreased.
if you have installed a fly screen on the wall-box, the air vent may be obstructed.
Check by removing the fly screen.
if the cover panel of the wall box is equipped with firm and slanted slats, the air vent
may be obstructed. Check by removing the cover panel.
install a cover panel with moveable slats, which do not obstruct the air vent.
check condition and cleanliness of the filters.
check if the air which is extracted by the hood is replaced to avoid negative pressure.
when you run your appliance in recirculating mode, check if the carbon filter has been
replaced on time ( min. every 6 months ).
8. TROUBLE SHOOTING
Summary of Contents for 8060G
Page 13: ...13 Abb 1...
Page 15: ...15 PKM 9040 60 90 PKM 9042 60...
Page 16: ...16 PKM 9080 PKM 9860...
Page 17: ...17 PKM 9861 PKM 9878...
Page 18: ...18 PKM 9878 langer Schacht PKM 9879...
Page 65: ...65 PKM 8060 G 8090 G PKM 9040 Fitting dimensions...
Page 66: ...66 PKM 9042 60 PKM 9080...
Page 67: ...67 PKM 9860 PKM 9861...
Page 68: ...68 PKM 9878 PKM 9878 extra long chimney...
Page 75: ...75 Changing the filters Models with acrylic filters...