Inputs configuration with manual start (CS AR-05••••) 

or monitored start (CS AR-06••••)

2 channels / Category 4 / up to SIL 3 / PL e

S21

S22

S34

A2

A1

-

+

S52

S12

OS2

OS1

IS2

IS1

A1

 +

ST D••••••

A2

-

Connections with safety modules CS AR-05•••• / CS AR-06••••

 1.7 CONNECTION WITH SAFETY MODULES

Connections with safety modules CS AR-08••••

Inputs configuration with monitored start

2 channels / Category 4 / up to SIL 3 / PL e

S33

S21

S22

S35

S34

A2

S52

S12

A1

-

+

OS2

OS1

IS2

IS1

A1

 +

A2

-

ST D••••••

Connections change depending on the program running on the module

 Category 4 / up to SIL 3 / PL e

Ixx

Ixx

OS2

OS1

IS2

IS1

A1

 +

ST D••••••

OS2

OS1

IS2

IS1

A1

 +

ST D••••••

Ixx

Ixx

A2

-

A2

-

Connections with safety modules CS MF••••0,  CS MP••••0

Inputs configuration with monitored start

2 channels / Category 4 / up to SIL 3 / PL e

S33

S21

S22

S35

S34

A2

A1

-

+

S31

S12

OS2

OS1

IS2

IS1

A1

 +

ST D••••••

A2

-

Connections with safety modules CS AT-0••••• / CS AT-1•••••

The  sensor  is  provided  with  a  dedicated  input,  which  enables  programming  of  the 

sensor  in  order  to  recognise  the  code  contained  in  a  new  actuator.  This  operation 

can  be  repeated  for  an  unlimited  number  of  times.  After  programming  has  been 

completed, the sensor will only recognise the actuator code corresponding to the last 

programming operation.

Warnings

•  The machine manufacturer must allow qualified personnel only

 to access the sensor 

programming mode.

• Observe all general directions.

• Observe all directions contained in the section for INSTALLATION AND CONNEC

-

TION INSTRUCTIONS.

• After completing the operation, check for new programmed actuator recognition and 

for sensor operation.

Programming procedure

• Supply the sensor with the rated voltage. The sensor carries out internal tests (1).

• The programming operation can be carried out with non-active safety inputs (2) as 

well as with active safety inputs (3).

• Activate the I3 programming input by bringing it to a 24 V voltage. The IN LED starts 

blinking  with  an  orange  light  to  indicate  that  it  is  waiting  for  the  new  code  to  be 

memorized (4).

•  Put  the  new  actuator  against  the  sensor,  aligning  the  reference  notches  with  the 

symbol  . After programming has been completed, the ACT LED emits four green 

blinks (5).

• When the ACT LED (6) switches off, it means that the programming operation has 

been successful. At this point deactivate the I3 programming input.

• The sensor automatically reactivates and power on self-tests (7) before being brought 

to the “RUN” state.

PWR 

LED

OUT 

LED

IN

LED

ACT 

LED

Sensor 

state 

Description

orange

/

/

/

POWER ON 

(1)

Internal tests on activation

green

/

/

/

RUN (2)

Sensor waiting for inputs

green

/

green

/

RUN (3)

Presence of inputs, waiting 

for the actuator 

green

/

orange 

blink

-

ing

/

PROGRAM

-

MING (4)

Programming input active, 

waiting for the new actuator to 

be programmed

green

/

orange green 

blink

-

ing x 4

PROGRAM

-

MING (5)

Programming input active. 

New code memorization 

successfully completed

green

/

orange

/

PROGRAM

-

MING (6)

Programming input active. 

Programming completed

orange

/

/

/

POWER ON 

(7)

Automatic restart and internal 

tests

Use  safety  sensor  with  the  actuator  linking  together  with  Pizzato  Elettrica  safety 

modules. The sensor connected to the safety module could be classified as control 

circuit device up to PDF-M (EN 60947-5-3 / A1).

 1.5 PROGRAMMING MODE

 1.6 OPERATIONAL STATES

PWR 

LED

OUT 

LED

IN

LED

ACT 

LED

Sensor 

state 

Description

/

/

/

/

OFF

Sensor off.

orange

/

/

/

POWER 

ON

Internal tests on activation.

green

/

RUN

Sensor inputs not active.

green

green

RUN

 Inputs activation.

green

green / 

orange 

blinking

RUN

Inputs inconsistency.

Recommended  action:  check 

the inputs and / or their wiring.

green

green

RUN

Actuator in the safe activation zone

Auxiliary output O3 active.

green

green / 

orange 

blinking

RUN

Actuator  in  the  limit  activation 

zone.  Recommended  action: 

bring the sensor within the safe 

activation zone.

green

green

green

green

RUN

Inputs activation. Actuator in the 

safe activation zone and safety 

outputs active.

green

red 

blinking

ERROR

Outputs error. 

Recommended action: check for 

short  circuits  between  outputs, 

outputs  and  ground,  or  outputs 

and  power  supply;  restart  the 

sensor.

red

ERROR Internal error. 

Recommended  action:  restart 

the sensor. If the fault persists, 

replace the sensor.

/  = off    

 = indifferent

© 2012 Copyright Pizzato Elettrica - original instructions

Summary of Contents for ST DD420MK

Page 1: ...all accensione nel quale il sensore compie dei test interni RUN stato nel quale il sensore è in funzionamento normale ERROR stato di sicurezza nel quale le uscite vengono disattivate Indica la presenza di un guasto interno al sensore un cortocircuito tra le uscite sicure OS1 OS2 un cortocircuito tra un uscita sicura e massa oppure un cortocircuito tra un uscita sicura e la tensione di alimentazion...

Page 2: ...S Sensor states OFF the sensor is switched off not powered POWER ON state immediately following switching on when the sensor carries out internal tests RUN state of the sensor in normal operation ERROR safety state in which the outputs are deactivated Indicates the presence of a fault inside the sensor a short circuit between the safety outputs OS1 and OS2 a short circuit between a safety output a...

Page 3: ... tacche di riferimento con sim bolo Il LED ACT a programmazione conclusa emette quattro lampeggii di colore verde 5 La programmazione è andata a buon fine allo spegnimento del LED ACT 6 Disat tivare quindi l ingresso di programmazione I3 Il sensore si riavvia automaticamente e riesegue dei test interni 7 per poi portarsi nello stato di RUN PWR LED OUT LED IN LED ACT LED Stato sensore Descrizione a...

Page 4: ...the sensor aligning the reference notches with the symbol After programming has been completed the ACT LED emits four green blinks 5 When the ACT LED 6 switches off it means that the programming operation has been successful At this point deactivate the I3 programming input The sensor automatically reactivates and power on self tests 7 before being brought to the RUN state PWR LED OUT LED IN LED A...

Page 5: ...iego Ue1 Tipo di uscita Corrente massima per uscita Ie1 Categoria d impiego Rilevamento cortocircuiti Protezione contro sovracorrenti Durata degli impulsi di disattivazione sulle uscite sicure Capacità ammessa tra uscita e uscita Capacità ammessa tra uscita e massa 24 Vdc PNP 0 25 A DC12 Ue 24 Vdc Ie 0 25 A Sì Sì 300 us 200 nF 200 nF Caratteristiche elettriche uscita di segnalazione O3 Tensione no...

Page 6: ...IS2 I3 Rated operational voltage Ue1 Absorbed rated current 24 Vdc 5 mA Safety output circuits OS1 OS2 Rated operational voltage Ue1 Signal type Max current for output Ie1 Utilization category Short circuits detection Protection against short circuits Time for deactivation impulses on safety outputs Capacity admitted between one output and the next Capacity admitted between output and ground 24 Vd...

Reviews: