4
troubleshooting
Fixture remains at blackout when illumination expected
• The
indicator should be lit - if not, check the
input power and fuse (see below).
• If live DMX is connected, the
indicator should
be lit - if not, check the DMX cable and the desk out-
put.
• Check that the selected
MODE
matches the desk per-
sonality being used.
• The master intensity channel for the current mode may
be set at zero. For
EX61
and
DMX
modes, check the
setting of
PERS
>
MINT
. For
EX61
mode,
MINT
must be set
ON
.
• Ensure that only one DMX device in the chain is set as
master.
• Standalone chase effects: Effects programmed using
PROG
>
C1
and
C2
but the fixture is not in
MODE
>
EF M
mode. Check also that
PROG
>
LEVL
is not
set at zero.
• Standalone RGB mixing: Colour values set within
MAN
section but the fixture is not in
MODE
>
MANU
mode.
Unexpected cell illumination occurring
• When using
DMX
mode: Check the setting of
PERS
>
RES
. See the section “DMX channel and cell layouts”
on page 2 for an explanation of the various resolution
modes.
fuse access
The single fuse is located next to the power and DMX
input connectors. Use a small flat blade screw driver to
twist the fuse holder anticlockwise until the carrier can be
extracted to reveal the fuse.
Specifications
Dimensions
Fuse type: 20mm 2A (T2AH)
anti-surge, ceramic body
Pin
Ground
Pin 2
Data –
Pin 3
Data +
Pin 5
Not used
Pin 4
Not used
Documentation by
Corporate Text & Design
(www.ctxd.com)
Release 1.07b (original panel)
Using master mode to drive other units
This unit can control any number of other Pixel Range fix-
tures via DMX links, without the need for a control desk.
1 Set this unit as
master
(
PERS
>
DATA
>
MAST
) and
ensure all others are set to
slave
(
PERS
>
DATA
>
SLAV
). Connect all fixtures via DMX daisy-chain.
2 Set each slave to
Mode
>
DMX
.
3 Set each slave DMX address (using
ADDR
>
DMX
) ac-
cording to the following:
18 cells are output in groups of 3 DMX channels to give
RGB values per cell (54 channels in total). Set the ad-
dress of each slave fixture according to which of the 18
cells you want them to appear within, or to begin with
(for multi-cell fixtures): (
A001
for cell 1,
A004
for cell 2,
...
A052
for cell 18). Set RGBA slave fixtures to 3 chan-
nel mode (using
PERS
>
RES
>
3ch
).
4 Set the master to
Mode
>
EF m
(
the master unit’s DMX
address is ignored).
On the master, choose the required
effects to display and send to the slave fixtures using
PROG
>
C1
and
C2
.
Weight
Fixture alone:
11kg (24 lbs)
With combi yoke:
12.2kg (26.9 lbs)
Power
Input voltage:
90 to 264V AC, 47 to 63Hz autosensing
Earth leakage
0.22mA
Connectors:
16 amp CEE Form 2Pole+Earth (input & output)
Power requirements:
@ 230V/50Hz
@ 115V/60Hz
Standby
20 watts
20 watts
Maximum (const.)
140 watts
140 watts
Start up (peak*)
32 amps
16 amps
* The peak value occurs only at first power up and
lasts only for a period measured in microseconds.
Adjustments may need to be made to supply circuit
breakers when multiple fixtures are daisy-chained,
causing them all to draw the peak simultaneously.
Approvals
Miscellaneous
Enclosure rating:
IP20 (not protected against moisture ingress)
Control input:
USITT DMX512 (input connector pin out below)
www.pixelrange.com
UK +44 (0)1905 363600
USA +1 865 675 3955