4
PIVOT CORPORATION
87-3, Shimookada Okada, Matsumoto-shi, Nagano, 390-0313 JAPAN
START
ENGINE
STOP
START
ENGINE
STOP
Troubleshooting
Trouble
Possible Causes
Possible Solutions
1
4
5
2
3
Basic Operation
Key Switch ON
(Engine start)
Key Switch OFF
(Engine stop)
Opening Demo
Real-time display
Meter OFF
Switching The Display and Setting
●
The needle will move to the lowest value side several times for searching position. Then it will move to the maximum value and finally to reading for current
measurement item.
Opening Demo
Needle of the boost gauge is shifted
to slightly negative from 0 when the
key switch ON and the engine is
stopped.
Depending on the altitude, needle shifts about one scale by the characteristics of car side
sensor(absolute pressure), but this is not a malfunction.
Does not work with Engine start.
Please check the “Fitting List” .
Please reconfirm whether wiring and
connections are correct or not.
The unit has been installed into an incompatible car
model.
OBD Connector
was connected when the key switch
was set to OFF, or car battery was changed.
C o n n e c t ag a i n
O B D C o nn e c to r
when the key switc h is set to O N
(engine start).
Poor connection of
Gauge cable
,
Link cable
,
6-pin Connector
,
OBD Connector
and
IGN cable
.
※
Our products have already been recognized as our Industrial Property or are in the process of receiving Industrial Property status.
※
We plan in the near future to take all possible legal measures to protect against unfair competition from look-alike products using similar designs, regulating characteristics,
circuitry and circuitry layout.
※
We strictly prohibit the unlicensed use of the PIVOT trademark and the unauthorized use of PIVOT User’ s Manual.
Measuring the lowest voltage
by voltmeter
1
2
●
Recommend to charge or replace the battery if it's lower
about 1V or more than when new.
START
ON
or
or
Without braking,
press down twice
With braking,
press down once
Press the switch
once
Peak reading display
Reset the Peak reading
Peak reading display
1
Real-time display
Reset the Peak reading
5
Real-time display
3
2
LED will light.
Press the switch
for 3 seconds
1
4
※
Each peak value can be reset by the key OFF.
B a c k t o r e a l - t i m e d i s p l ay a f t e r 3
seconds releasing the switch.
Pressing the switch while displaying the
peak reading will re-set the peak reading.
LED will light off.
Real-time display
Setting warning point display
Setting of Warning
LED will brink.
Release
the switch
Press the switch
for 3 seconds
Press
the switch
Each pressing of
t h e s w i t c h w i l l
r a i s e , a t t h e
maximum point it
will return to the
minimum point.
3
2
4
1
5
While holding down
the switch, change the warning setting.
※
By continually pressing down on the switch the needle will
move to the maximum point.
※
Can't make setting of Warning while displaying Peak reading(LED lighting).
L E D w i l l l i g h t o f f a n d b a c k t o
real-time display after 3 seconds
releasing the switch.
While the meter is in operation, press
the switch once.
Turn the key switch
ON and display the
meter
Start the engine and
check the lowest
voltage with Peak
reading display
While the meter is in operation,
press the switch for 3 seconds.