SUBMERSIBLE PUMP
EN
9
OPERATING CONDITIONS
9.1
ENVIRONMENTAL CONDITIONS
TEMPERA-
TURE
min. +12 °F / max +104 °F
min. -11 °C / max +40 °C
RELATIVE
HUMIDITY
max. 100%
ATTENTION
The temperature limits shown apply to the pump components and must be
respected to avoid possible damage or malfunction.
ATTENTION
The pump does not work with frozen fluid.
Consult the fluid data sheet for the range of use.
9.2 ELECTRICAL POWER SUPPLY
NOTE
The pump must be powered by a single-phase line in alternating current whose
nominal values are indicated in the table in the paragraph “TECHNICAL DATA”.
The maximum acceptable variations for the electrical parameters are:
Voltage: +/- 5% of the nominal value
ATTENTION
Power supply from lines with values that do not fall within the indicate limits could
cause damage to the electrical components and reduction of working perfor-
mance.
9.3 TYPE DE SERVICE
The pump have been designed for continuous duty (service S1).
NOTE
The timer is used to avoid forgetting the pump on. The timer automatically
switches off the pump after about 11 minutes of running.