![Piusi SQUALO Installation, Use And Maintenance Instructions Download Page 8](http://html.mh-extra.com/html/piusi/squalo/squalo_installation-use-and-maintenance-instructions_1560390008.webp)
M0629
8
/52
Installation, use and maintenance
6
FIRST AID RULES
Persons who
have suffered
electric shock
Disconnect the power source, or use a dry insulator to protect yourself while
you move the injured person away from any electrical conductor. Avoid
touching the injured person with your bare hands until he is far away from
any conductor. Immediately call for help from qualified and trained person-
nel. Do not operate switches with wet hands.
7
GENERAL SAFETY RULES
ESSENTIAL PROTEC-
TIVE EQUIPMENT
CHARACTERISTICS
Wear protective equipment that is:
• Suited to the operations that need to be performed;
• Resistant to cleaning products.
PERSONAL
PROTECTIVE
EQUIPMENT
THAT MUST BE
WORN
Safety shoes;
Close-fitting clothing;
Protection gloves;
Safety goggles;
OTHER
DEVICES
Instructions manual
8
TECHNICAL DATA
Voltage/Frequency (V/Hz)
120/60
Absorption (Amps)
9,0
Power (Watt / HP)
380 / 1/2
RPM
3600
Nominal Flow Rate (GPM)
10
Max Back Pressure (bar / psi)
2,3 / 33
Type of Service
(S1-continuous; S3-periodic intermittent)
S1
Tank minimum level (mm / in)
30 / 1,18
Capacitor capacitance (
µ
F)
2x18
Switching on for every hour
30
Max Immersion (m/Ft)
5 / 17
ATTENTION
The data refers to the following operating conditions:
Fluid: water
Temperature: 20° C