Installation and use
11.4 WIRINGS
FOREWORD
For each product, open the PW-LAN cover to access the hardware area.
NOTE
The power supply of the device must be protected with a magnetothermic
circuit breaker.
Maximum rated current: 20 A
The rated current must in any case be coordinated with the power supply
cable.
MC BOX 2.0
CUBE MC 2.0
SELF SERVICE
MC 2.0
Disconnect the power supply
cable (if already connected)
(Shown in the image).
Insert the PW Mobile power
supply cable through the
cable gland as shown in the
image (use the light cable
gland, not used for other wir-
ings).
Once the PW Mobile cable
has been introduced, con-
nect the terminals to the ex-
isting power cable (remove
the crimped bushings and
use new ones with two-wire
housing, if necessary). Re-
connect securing the cables
firmly.
Remove the protective cover
of the terminal board locat-
ed in the lower right corner
of the panel.