pneumatic supply to the Piusi MA and Piusi MP
pumps must be made using FILTERED, DRIED, NON
LUBRICATED OIL FREE AIR at a pressure of not less
than 2 bars and not more than 7 bars.
do not remove RESET for any reason and/or do not
con-nect the air supply to the RESET channel.
to measure the actual air pressure, install a pressure
gauge on the air connection of the pump and check
the value while the pump is running.
WARNING
WARNING
REMARK
N
PNEUMATIC CONNECTION
To connect the pump to the pneumatic circuit, you must:
1. Remove the adhesive sticker from the air connection.
2. Install an on-off valve, a three-way valve and a check valve on the pneumatic cir-
cuit connection on board the pump according to the layout shown in figure 1.
ONLY FILTER
NO OIL