![Piusi K33 Atex Manual Download Page 29](http://html.mh-extra.com/html/piusi/k33-atex/k33-atex_manual_1560360029.webp)
M0217 EN
29
EN
P
PROBLEMS, CAUSES AND SOLUTIONS
For any problems contact the authorised dealer nearest to you.
Problem
Possible cause
Corrective action
Leak from the-
shaft gasket
t%BNBHFEHBTLFU
Remove (see section “Gear unit”) an-
dreplace the O ring and the bush
Insufficient ac-
curacy
t8SPOHDBMJCSBUJPO
Repeat calibration following the in-
structions in section “Measuring cham-
ber”
t4PJMFEPSCMPDLFENFB
-
suring chamber.
Clean the measuring chamber follow-
ing the instructions in section “Meter
unit”
t"JSJOUIFøVJE
Locate and eliminate leaks in inlet lines
Reduced flow-
rate
t $MPHHFE PS CMPDLFE
measuring chamber
Clean the measuring chamber follow-
ing the instructions in section “Measur-
ingchamber”
t#MPDLFEPSTPJMFEöMUFS
Clean the filter
Q
DEMOLITION AND DISPOSAL
Foreword
If the system needs to be disposed, the parts which make it up must be
delivered to companies that specialize in the recycling and disposal of
industrial waste and, in particular:
Disposal of pack-
ing material
The packaging consists of biodegradable cardboard which can be deliv-
ered to companies for normal recycling of cellulose.
Disposal of metal
parts
Metal parts, whether paint-finished or in stainless steel, can be consigned
to scrap metal collectors.
Disposal of electric
and electronic
components
These must be disposed of by companies that specialize in the disposal
of electronic components, in accordance with the indications of directive
2002/96/CE (see text of directive below).
Information
regarding the envi-
ronment for clients
residing within the
European Union
European Directive 2002/96/EC requires that all equipment marked
with this symbol on the product and/or packaging not be disposed of
UPHFUIFSXJUIOPOEJòFSFOUJBUFEVSCBOXBTUF5IFTZNCPMJOEJDBUFTUIBU
this product must not be disposed of together with normal household
waste. It is the responsibility of the owner to dispose of these products
as well as other electric or electronic equipment by means of the spe-
cific refuse collection structures indicated by the government or the local
governing authorities.
Disposal of miscel-
laneous parts
Other components, such as pipes, rubber gaskets, plastic parts and wires,
must be disposed of by companies specialising in the disposal of indus-
trial waste.
Summary of Contents for K33 Atex
Page 1: ...M0268ITEN _ 00 K33 ATEX ...
Page 2: ......
Page 16: ...16 M0268 IT IT R VISTE ESPLOSE MISURE DI INGOMBRO ...
Page 30: ...30 M0217 EN EN R EXPLODED VIEWS ...
Page 31: ......