Piusi K33 Atex Manual Download Page 17

M0217 EN                                            

 

 

 

 

 

      17

EN

TABLE OF CONTENTS

TABLE OF CONTENTS 

 

 

 

 

19

B  

CONFORMITY 

 

 

 

 

20

MACHINE DESCRIPTION 20

 

C1 

DEFINITION OF CLASSIFIED ZONES    

 

21

 

C2 

INTENDED USE 

 

 

 

22

 

C3 

HANDLING AND TRANSPORT 

 

 

22

GENERAL WARNINGS   

 

 

 

23

FIRST AID RULES 

 

 

 

 

23

GENERAL SAFETY RULES 

 

 

 

24

TECHNICAL DATA 

 

 

 

 

25

OPERATING CONDITIONS 

 

 

 

25

 

H1 

ENVIRONMENTAL CONDITIONS 

 

 

25

 

H2 

FLUIDS PERMITTED  

 

 

 

25

INSTALLATION 

 

 

 

 

26

CALIBRATION 

 

 

 

 

27

EVERY DAY USE 

 

 

 

 

28

MAINTENANCE 

 

 

 

 

29

DISASSEMBLING REASSEMBLING 

 

 

 

30

PROBLEMS, CAUSES AND SOLUTIONS 

 

 

31

DEMOLITION AND DISPOSAL 

 

 

 

31

EXPLODED VIEWS 

 

 

 

 

32

Summary of Contents for K33 Atex

Page 1: ...M0268ITEN _ 00 K33 ATEX ...

Page 2: ......

Page 3: ...TINAZIONE D USO 6 C3 MOVIMENTAZIONE ETRASPORTO 6 D AVVERTENZE GENERALI 7 E NORME DI PRONTO SOCCORSO 7 F NORME GENERALI DI SICUREZZA 8 G DATITECNICI 9 H CONDIZIONI OPERATIVE 9 H1 CONDIZIONI AMBIENTALI 9 H2 FLUIDI AMMESSI 9 IINSTALLAZIONE 10 L CALIBRAZIONE 11 M USO GIORNALIERO 12 N MANUTENZIONE 13 O DISSASSEMBLAGGIO E RIASSEMBLAGGIO 14 P PROBLEMI E SOLUZIONI 14 Q DEMOLIZIONE E SMALTIMENTO 15 R VISTE...

Page 4: ... 2012 ____________________ Legale Rappresentante C DESCRIZIONE DELLA MACCHINA I contalitri K33 ATEX sono di tipo meccanico a disco oscillante studiatiperconsentireunaprecisamisurazionedigasolioodial tri liquidi compatibili con i materiali costruttivi Il disco oscillante della camera di misura vedi schema 1 insieme 15 mosso dal fluido aziona il treno d ingranaggi alloggiato nel coperchio del corpo ...

Page 5: ...nebbia sipresentiduranteilnormalefunzionamento mache se si presenta persiste solo per un breve periodo Nota Dettazonapuòcomprendere traglialtri luoghicircostantilezone 0o1 ZONA20 Luogo in cui un atmosfera esplosiva sotto forma di una nube di polveri combustibili nell aria è presente continuamente o per lunghi periodi o frequentemente Nota In generale dette condizioni quando si presentano interessa...

Page 6: ... quella prevista dal fabbricante 2 Utilizzarel apparecchiaturaconiriparifissimanomessiorimossi 3 Utilizzare l apparecchiatura in luoghi a rischio di esplosione e o incendio classificati nelle seguenti zone 0 20 21 22 4 Integrare altri sistemi e o attrezzature non considerati dal co struttore nel progetto esecutivo 6 Utilizzare i dispositivi commerciali per uno scopo diverso da quelli previsti dal ...

Page 7: ...usatoinaltristampati senza autorizzazione scritta della Piusi S p A Piusi S p A IL PRESENTE MANUALE È PROPRIETÀ DELLA Piusi S p A OGNI RIPRODUZIONE ANCHE PARZIALE E VIETATA NOTA QUESTO MANUALE è VALIDO SOLO PER CONTALITRI K33 ATEX ATTENZIONE PRIMADIPROCEDEREALRIFORNIMENTODIVELIVOLI ASSICURARSICHEL IMPIANTODESTINATOATALE AZIONESIACONFORMEALLENORMATIVEINMATERIA VIGENTINELPAESEDIUTILIZZO ATTENZIONE U...

Page 8: ...icurezza manuale di istruzioni Guantipro tettivi Il contatto prolungato con il prodotto trattato può provoca re irritazione alla pelle durante l erogazione utilizzare sem pre i guanti di protezione NOTA PER EVITARE L INNESCO DI SCINTILLE TUTTO L IM PIANTO DEVE AVERE ADEGUATA MESSA A TERRA COMPRESI SERBATOIO E TUTTI GLI EVENTUALI ACCESSORI ATTENZIONE LA MANCATA OSSERVANZA DELLE NORME SOPRA ELENCATE...

Page 9: ...i in qualsiasi posizione sia su tubazioni rigide che flessibili nonchè direttamente su pompe o serbatoi Il contalitri ha una direzione di flusso prefissata indicata da una freccia e viene fornito nella configurazione standard A Il contatore e il coperchio vedi schema1 posiz 3 possono essere ruotati di 90 in 90 rispetto al corpo per realizzare le restanti configurazioni illustrate B C D La manopola...

Page 10: ...nutenzione o quando sia utilizzato per misurare fluidi diversi dal gasolio COME CALIBRARE 1 Svitare il tappo di chiusura vedi schema 1 posiz 14 2 Eliminare tutta l aria dal sistema pompa tubazioni contalitri erogando fino a ottenere un flusso pieno eregolare 3 Arrestare il flusso chiudendo la pistola di erogazione senza arrestare lapompa 4 Azzerare l indicatore parziale agendo sulla manopola posiz...

Page 11: ...atore del totale non può essere azzerato in alcun modo Assicurarsi che durante l uso la pressione di esercizio non superi il valore indicato alla sezione Dati tecnici USO PER GRAVITA Il contalitri K33 ATEX può essere utilizzato anche in impianti sprovvisti di pompe nei quali il flusso è generato dal dislivello tra il fluido nel serbatoio e la bocca di uscita della pistola di erogazione A titolo di...

Page 12: ... CHIO E OBBLIGATORIO SOSTITUIRE LE PARTI DANNEGGIATE A GARANZIA DELLA SICUREZZA è NECESSARIO UTILIZZARE ESCLUSIVAMENTE RICAMBI ORIGINALI Avvertenze di sicurezza Durante la manutenzione è obbligatorio utilizzare i dispositivi di prote zione individuale DPI Tenere comunque in considerazione le seguenti raccomandazioni mini me per un buon funzionamento DELL APPARECCHIO ATTENZIONE PRIMA DI EFFETTUARE ...

Page 13: ... la bocca di ingresso per estrarre l O ring dalla sua sede nella bocca di uscita Per ispezionare l interno della camera di misura rimuovere l O ring e separare le EVF TFNJDBNFSF DPOUFOFOUJ JM EJTDP PTDJMMBOUF 1FS JM SJNPOUBHHJP FòFUUVBSF MF PQFSB zioni in ordine inverso avendo particolare cura nel A Controllare che il disco oscillante ruotiliberamente nella camera di misuraassiemata B Installare c...

Page 14: ...la bussola Precisione insoddisfacente t BMJCSB JPOF FSSBUB Ripetere la calibrazione seguendo le indicazioni della sez Camera dimisura t BNFSB EJ NJTVSB TQPSDB o ostruita Pulire la camera di misura seguendo le istruzioni della sezione Gruppo contatore t 1SFTFO B EJ BSJB OFM øVJEP Individuare ed eliminare le perdite nelle linee in aspirazione Bassa portata t BNFSB EJ NJTVSB bloccata o ostruita Pulir...

Page 15: ...o dei componenti elettronici in conformità alle indicazioni della direttiva 2002 96 CE vedi testo direttiva nel seguito Informazionirela tiveall ambiente periclientiresi dentinell unione europea LadirettivaEuropea2002 96 ECrichiedecheleapparecchiaturecontras segnate con questo simbolo sul prodotto e o sull imballaggio non siano TNBMUJUF JOTJFNF BJ SJöVUJ VSCBOJ OPO EJòFSFO JBUJ M TJNCPMP JOEJDB DI...

Page 16: ...16 M0268 IT IT R VISTE ESPLOSE MISURE DI INGOMBRO ...

Page 17: ...NDTRANSPORT 22 D GENERALWARNINGS 23 E FIRST AID RULES 23 F GENERAL SAFETY RULES 24 G TECHNICAL DATA 25 H OPERATING CONDITIONS 25 H1 ENVIRONMENTAL CONDITIONS 25 H2 FLUIDS PERMITTED 25 I INSTALLATION 26 L CALIBRATION 27 M EVERY DAY USE 28 N MAINTENANCE 29 O DISASSEMBLING REASSEMBLING 30 P PROBLEMS CAUSES AND SOLUTIONS 31 Q DEMOLITION AND DISPOSAL 31 R EXPLODEDVIEWS 32 ...

Page 18: ...p Place Suzzara Mn Date 22 02 2012 Legal Representative C MACHINE DESCRIPTION K33 atex is mechanical flowmeter with nutating disk designed toallow a precise measurement of Diesel oil or other fluids compatible with the manufacturing material The nutating disk of the metering chamber seediagram 1 drawing 15 which is setin motion by the fluid itself drives thegear train located in the cover of theme...

Page 19: ... can occur during normal operation but which if it does oc curs only persists for a short time Note Said zone can include among others places surrounding the zones 0or1 ZONE20 Place where an explosive atmosphere in the form of a cloud of com bustible powders in the air is continuously present either for long periods or frequently Note Generally speaking said conditions when they occur involve the ...

Page 20: ...ppliance with fixed guards tampered with or removed 3 To use the appliance in places where there is risk of explo sion and or fires classified in the following zones 0 20 21 22 4 To integrate other systems and or equipment not consid ered by the manufacturer in the executive project 5 To connect the appliance up to energy sources other than those contemplated by the manufacturer 6 To use the comme...

Page 21: ...si S p A THIS MANUAL ISTHE PROPERTY OF Piusi S p A ANY REPRODUCTION EVEN PARTIAL IS FORBIDDEN NOTE THISMANUALISVALIDONLYFORK33ATEXMETER ALWAYSUSETHERIGHTVOLTAGESTOCONNECTTHE PUMPS ATTENTION BEFOREPROCEEDINGWITHTHEREFUELLINGOFTHE AIRCRAFT ENSURE THAT THE SYSTEM INTENDED FOR SUCH ACTION COMPLIES WITH THE REGULA TIONSINFORCEINTHECOUNTRYOFUSE ATTENTION USETHEMETERONLYWITHFLUIDSPERMITTED DONOTUSEWITHFL...

Page 22: ...UR wear protective equip ment which is t TVJUFE UP UIF PQFSBUJPOT UIBU OFFE UP CF QFSGPSNFE t SFTJTUBOU UP QSPEVDUT VTFE TO DO SO PLEASE REFER TO THE RELEVANT TECHCNICAL DATASHEETS OFTHE FLUID USED Personal protective equipment that must be worn safety shoes close fitting clothing protection gloves safety goggles Necessary safety devices instructions manual Protective gloves Prolonged contact with...

Page 23: ...eight approximate 1 8 Kg 1 9 Kg Package dimensions 185x185x170 mm Optional features Registration in US gallons female threaded inlet outlet 1 NPT H OPERATING CONDITIONS H1 ENVIRONMENTAL CONDITIONS AMBIENT TEMPERATURE min 23 F max 140 F min 10 C max 60 C FLUID TEMPERATURE min 23 F max 140 F min 10 C max 60 C RELATIVE HUMIDITY max 90 LIGHTING The environment must conform to directive 89 654 EEC on w...

Page 24: ...uipped with 4 blind holes see diagram 2 which can be threaded M5 for a possible fastening If solid particles enter the measuring chamber the correct XPSLJOH PG UIF OVUBUJOH EJTL NBZ CF BòFDUFE MXBZT öM ter the fluid by installing a filter on the meter inlet rec ommended filter 400 μ A B C D ATTENTION BEFORE ANY OPERATION ENSURE TO BE OUT OF POTENTIALLY EXPLOSIVE AREAS Themetermustneverbeoperatedbe...

Page 25: ...t knob pos 2 5 Dispense at the flow rate which thebest accuracy is re quired at by using a calibration container having a ca pacity not lower than 20 litres Do not reducethe flow in order to reach the graduated zone of the calibration con tainer Theright method is to start and stop the fullflow repeatedly until the required fillingis obtained 6 Compare the indication of the calibration container r...

Page 26: ...egister is completely reset The totaliser cannot be reset in any way Make sure that during use pressure does not exceed the value indicated insection Technical data USEBYGRAVITY K33 ATEX can also be used in fuel units which are not equipped with pump sand where the flow is generated CZ UIF EJòFSFODF JO GVFM MFWFM CFUXFFO UIF UBOL BOE UIF nozzle outlet As a reference a system composed ofa UBOL Pò U...

Page 27: ...ist A new calibration is always necessary after cleaning or replacing the meter parts ATTENTION TOMAINTAINTHESAFETYOFTHEAPPLIANCE ITIS MANDATORYTOREPLACETHEDAMAGEDPARTS FORSAFETYPURPOSES YOUMUSTUSEONLYGEN UINESPAREPARTS Safety instruc tions During maintenance the use of personal protective equipment PPE is compulsory Inanycasealwaysbearinmindthefollowingbasicrecommendationsfor a good functioning o...

Page 28: ...ds the inlet in order toremove the O ring pos 16 from its seat at the outlet To check the inside of the measuring chamber pos 15 remove the O ring and di vide the two half chambers containing the nutating disk Measuring chamberTo enter the measuring chamber operate as follows A Check that the nutating disk rotates freely in the ASSEM BLED measuring chamber B Install the gasket seals correctly afte...

Page 29: ...sists of biodegradable cardboard which can be deliv ered to companies for normal recycling of cellulose Disposalofmetal parts Metalparts whetherpaint finishedorinstainlesssteel canbeconsigned to scrap metal collectors Disposalofelectric andelectronic components These must be disposed of by companies that specialize in the disposal ofelectroniccomponents inaccordancewiththeindicationsofdirective 20...

Page 30: ...30 M0217 EN EN R EXPLODED VIEWS ...

Page 31: ......

Page 32: ...M02268 ITEN _ 00 Piusi S p A 46029 Suzzara Mantova Italy www piusi com The Company reserves the right to modify the information contained in this user manual without any prior notice ...