Piusi DELPHIN PRO X Quick Manual Download Page 13

13

/124

13 

/20

EN

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 

delphin PRO_X   QUICK GUIDE

translated from italian

4  CUSTOMIZE THE SYSTEM 

Customizing the SYSTEM means using the OFFERS options to make its use 

easier, more convenient and more precise.

ACCESS TO THE CUSTOMIZATION MENU, OFFERS THE POSSIBILITY 

OF:

- SELECT THE UNIT OF MEASUREMENT.

- MODIFY the calibration factor (K Factor).

- MAKE CALIBRATIONS IN THE FIELD WITH RECIPIENT GRADUATED

- MAKE A DIRECT MODIFICATION OF THE CALIBRATION FACTOR.

To access the various customizing functions and select the desired options, 

two different actions are possible on the keys:

This symbol indicates the necessity 

to press the key briefly

 with conse-

quent release.

This symbol indicates the necessity 

to press and keep pressed the key

 for 

a few seconds.

+

TO ACCESS THE MENU, PRESS AND SET THE «RESET» AND «ENTER» 

BUTTONS LONG AS THE DISPLAY SHOWS THE «TOTAL» WRITING ON 

THE DISPLAY.

The SYSTEM displays: 

 

To exit the personalization menu, whatever the activity you are in, press 

RESET. The settings displayed at that moment become immediately op-

erational.

SELECTING THE UNIT OF MEASUREMENT

The SYSTEM allows the user to select one of the following Units of Mea-

surement:

LIT = LITERS

GAL = GALLONS (U.S. Gallon).

QTS = QUARTS

The above-mentioned Units of Measurements refer to the Batch total indi-

cation.

When the DISPLAY displays:

Blinking

Press ENTER to go to the next Unit of Measurement.

Keep on pressing ENTER until the desired Unit of Measurement is displayed.

Summary of Contents for DELPHIN PRO X

Page 1: ...n M0495A EN _ 00 Delphin PRO_X quick guide RESET on off STATUS MADE IN ITALY RESET Preset Not for resale Flow Rate REFILL 3sec POWER 0 1 1 10 ENTER AUTO FLOW max min DELPHINPRO X Delphin PRO_X _ quick guide EN ...

Page 2: ...SE 5 2 1 SETTING THE PRESET FUNCTIONS 5 2 2 MANUAL DISPENSING 6 2 3 DISPENSING WITH AUTOMATIC FLOW 8 2 4 SHUTDOWN OF THE SYSTEM 9 3 SYSTEM COMMUNICATIONS 10 3 1 REGULAR OPERATION 10 3 2 BATTERY INDICATIONS FOR DC VERSIONS 11 3 3 ALARM SIGNALS THAT DO NOT BLOCK THE SYSTEM 12 3 4 ALARM SIGNALS THAT BLOCK THE SYSTEM 12 4 CUSTOMIZE THE SYSTEM 13 ...

Page 3: ...reached The interface of the management system is represented by the plate key pad which includes the function keys the LCD screen and the communica tion LEDS RESET on off STATUS MADE IN ITALY RESET Preset Not for resale Flow Rate REFILL 3sec POWER 0 1 1 10 ENTER AUTO FLOW max min DELPHINPRO X 1 2 5 6 7 8 9 4 3 1 POWER button used to power the system 2 REFILL button press for at least 3 seconds to...

Page 4: ...T Liters GAL Gallons QTS Quarts 5 Indication of operation in AUTO mode 1 3 LEGENDS FUNCTION KEYS Numeric keys to be used to set the PRESET value automatic dispense stop value ENTER key to be used to select and confirm the PRESET value RESET key to be used to reset the Batch Total and to display the Resettable TOTAL LEDS COMMUNICATION Representation pulses Description LED always on Flashing 1 IMPUL...

Page 5: ...he preset value in more ways 1 Direct setting of a new PRESET value The SYSTEM allows the user to directly set the PRESET value by means of the numeric keys If THE SYSTEM is turned off TURN ON BY PRESSING THE POWER BUTTON The DISPLAY will display Non resettable Total To select a new PRESET value for example 12 3 use the numeric keys The DISPLAY will display Selected value To confirm the PRESET val...

Page 6: ...ows The DISPLAY displays Last amount dispensed Non resettable Total The SYSTEM can be programmed to display the last amount dispensed until the RESET button is pressed or to automatically reset the Batch Total a few minutes after a dispensing operation in MANUAL mode Resetting the Batch Total To reset the batch total press RESET The DISPLAY will display Resettable Batch total Resettable General To...

Page 7: ...POWER 0 1 1 10 ENTER AUTO FLOW max min HINPRO X RESET on off STATUS RESET Preset Not for resale REFILL 3sec POWER 0 1 1 10 ENTER X During dispensing the up per LEDs will flash alter nately RESET on off STATUS MADE IN ITALY RESET Preset Not for resale Flow Rate REFILL 3sec POWER 0 1 1 10 ENTER AUTO FLOW max min ELPHINPRO X RESET on off STATUS MADE IN ITALY RESET Preset Not for resale Flow Rate REFI...

Page 8: ... 4 Press the REFILL button for 3 seconds a top LED flashes and dispensing starts RESET on off STATUS DE IN ITALY RESET Preset Not for resale Flow Rate REFILL 3sec POWER 0 1 1 10 ENTER AUTO FLOW max min HINPRO X RESET on off STATUS RESET Preset Not for resale REFILL 3sec POWER 0 1 1 10 ENTER X During dispensing the upper LEDs will flash al ternately RESET on off STATUS MADE IN ITALY RESET Preset No...

Page 9: ...l not be possible during dis pensing to switch to manual mode NOTE Once the delivery has been completed THE SYSTEM AUTOMATICALLY PREPARES A NEW DISPENSING 2 4 SHUTDOWN OF THE SYSTEM ATTENTION The dc models are equipped with a battery saving system that automatically turns off the system after 10 minutes of unusing The system turns off completely if not used for at least 10 minutes but keeps the po...

Page 10: ...OWER 0 1 1 10 ENTER 2 DISPENSING IN PROGRESS green LEDs ON OFF and STATUS flash alternately The system is dispensing on off STATUS RESET Preset Not for resale REFILL 3sec POWER 0 1 1 10 ENTER 3 FULLTANKFORREACHINGTHELEVEL LED ON OFF REMAINS ON FIXED WHILE FLASHING THE TOTAL SUP PLIED DISPLAYED ON THE DISPLAY The system has dispensed until reach ing the maximum tank level 4 INPRESETMODE PRE SETQUAN...

Page 11: ...c OWER 0 1 1 R T on off STATUS RESET Preset Not for resale REFILL 3sec POWER 0 1 1 10 ENTER RESET on off STATUS RESET Preset Not for resale REFILL 3sec POWER 0 1 1 10 ENTER 1 INDICATIONS BATTERY STATUS LEDs for battery on steady in charge status color If the battery is charged only the GREEN LED will be on steady Permit ted supply If the battery is half charged only the YELLOW LED will be steady A...

Page 12: ...C TION BATTERY DISCONNECTED BATTERY DAMAGED Fixed alarm red LED Dispensing is possible but check that the battery is connected If the problem persists contact the Piusi Service If the battery is damaged replace it 3 4 ALARM SIGNALS THAT BLOCK THE SYSTEM Alarms reported to be resolved that prevent dispensing on off STATUS RESET Preset Not for resale REFILL 3sec POWER 0 1 1 10 ENTER 1 IN MANUAL MODE...

Page 13: ...ymbol indicates the necessity to press the key briefly with conse quent release This symbol indicates the necessity to press and keep pressed the key for a few seconds TO ACCESS THE MENU PRESS AND SET THE RESET AND ENTER BUTTONS LONG AS THE DISPLAY SHOWS THE TOTAL WRITING ON THE DISPLAY The SYSTEM displays To exit the personalization menu whatever the activity you are in press RESET The settings d...

Page 14: ...ACTOR The SYSTEM is pre calibrated at the factory Why calibrate If the SYSTEM is used in extreme conditions of flow close to the minimum or maximum values of the admitted field it may be appropriate to carry out a calibration in the field carried out under the actual conditions of use How to calibrate The SYSTEM allows the user to carry out a fast and accurate electronic calibration by modifying t...

Page 15: ... and resumed The Calibration dispensing is finished when the fluid level reaches the grad uated area in the calibrated container Blinking Indicated value To obtain a correct METER calibration it is necessary To use an accurate sample container having a capacity not less than 5 li ters Completely purge all air from the unit before performing the calibration Make the calibration delivery at constant...

Page 16: ...d value Each time a key is pressed the last digit on the right is modified by one unit By keeping the keys pressed the value changes slowly at first and then rapidly DISPLAY Sample container INDICATED VALUE Blinking REAL VALUE Press ENTER to confirm the end of the indicated value correction The SYSTEM now calculates the new Calibration factor K Factor and dis plays CAL End Blinking alternately New...

Page 17: ...ication of the K Factor Press the 10 key to increase the indicated value Press the 0 1 key to decrease the indicated value Each time a key is pressed the last digit on the right is modified by one unit By keeping the keys pressed the value changes slowly at first and then rap idly Press the ENTER key to confirm that the correction of the indicated value is over The SYSTEM stores the new Calibratio...

Page 18: ...M0495A 18 20 quick guide to use ...

Page 19: ...19 124 19 20 EN This manual is the property of PIUSI S p A Any reproduction even partial is forbidden delphin PRO_X QUICK GUIDE translated from italian ...

Page 20: ...n up with the greatest attention to precision and accuracy of all data herein contained Nevertheless PIUSI S p A denies liability for any possible mistake or omission PIUSI S p A Download the manual in your language http www piusi com manual delphin pro pro x ibc ...

Reviews: