DMX Set Up

 

  FIRST-PL067 User Manual Page 5

 

 

 

 

DMX-512: 

DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication 

between  intelligent  fixtures  and  controllers.    A  DMX  controller  sends  DMX  data  instructions  from     
the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the 
DATA 

“IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a 

DATA 

“OUT” terminal).

 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models  of  different  manufactures  to  be 

linked together and operate from a single controller, as long as all fixtures and the controller are DMX 
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use    the 
shortest  cable  path  possible.  The  order  in  which  fixtures  are  connected  in  a  DMX  line  does  not 
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed 
anywhere in  a DMX line,  at the beginning,  at  the end,  or anywhere in  the middle. When a fixture is 
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that 
unit, no matter where it is located in the DMX chain.

 

Data  Cable  (DMX  Cable)  Requirements  (For  DMX  Operation): 

The  PL067  can  be  controlled  via 

DMX-512 protocol. The PL067 has 2 DMX channel modes. The DMX address is set on the back panel 
of the PL067. Your unit and your DMX controller require a standard 3-pin XLR connector for data input 
and data output. We recommend Accu-Cable DMX cables. If you are making your own cables, be sure 
to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all  pro  lighting 
stores). 

 

 

Notice: 

Be sure to follow figures two and three when making your own cables. Do not use the ground 

lug on the XLR connector. Do not connect the 

cable’s shield conductor to the ground lug or allow the 

shield conductor to come in contact with the 

XLR’s outer casing. Grounding the shield could cause a 

short circuit and erratic behavior.

 

 

DMX512 OUT 

3-PIN XLR

 

DMX512 IN 

3-PIN XLR

 

 

 

Figure 1

 

 

 

 

 

 

Figure 2

 

 

 

 

 

 

 

 

 

XLR Pin Configuration

 

Pin 1 = Ground

 

Pin 2 = Data Compliment (negative)

 

Pin 3 = Data True (positive)

 

 

COMMON

 

  

DMX + 

 

1

 

2  

DMX - 

2

 

 

 

Summary of Contents for PLUSlite First-PL067

Page 1: ...First PL067 IP65 ParLed User Instructions https www piu39av com pluslite lighting ...

Page 2: ...n be used in a stand alone mode or connected in a Master Slave configuration This par has multiple operating modes RGBW dimmer mode Static Color mode Auto Run mode Color Macro mode and DMX control This product is intended to be used by professionally trained personnel only and is not suitable for private use These instructions contain important safety information regarding the use and maintenance ...

Page 3: ...perating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit s weight Also always use a safety cable that can hold 12 times the weight of the unit when installing the fixture The equipment must be installed by a professional and it must be installed in a place where it is out of the reach of people s grasp Ensure ALL c...

Page 4: ...ufacturer See page 24 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the fixture C The fixtu...

Page 5: ...ion indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and low pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note although this fixture is IP rated the fixture is NOT suitable for marine and or coastal environment installati...

Page 6: ...FIRST PL067 Layout PL067User Manual Page 4 IP65 Locking Power Connection In Out IP65 Locking Singal 3P Connector In Out LED Display Mode button Up button Down button Enter button ...

Page 7: ...ing at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The PL067 can be controlled via DMX 512 protocol The PL067 has 2 DMX channel modes The DMX address is set on the back panel of the PL067 Your...

Page 8: ...rom which thefixture startsto listen to thedigitalcontrolsignalsent outfrom the DMXcontroller The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display on the fixture You can set the same starting address for all fixtures or a group of fixtures or set different addresses for each individual fixture Setting all fixtures to the same DMX...

Page 9: ...r 0 100 0 255 8CH Describe Parameter CH1 Main Dimming 0 255 CH2 Strobe Speed 0 255 CH3 Dimming Mode Macro Color 1 Macro Color 2 Macro Color 3 Macro Color 14 Macro Color 15 Ayto Mode Pluse Mode Gradual Mode 0 10 11 20 21 30 31 40 141 150 151 160 161 190 191 220 221 225 CH4 Mode Speed 0 255 CH5 R Dimming 0 255 CH6 G Dimming 0 255 CH7 B Dimming 0 255 CH8 W Dimming 0 255 ...

Page 10: ...Describe Parameter D001 DMX 4CH Mode Master Slave Mode 1 512 A001 DMX 8CH Mode Master Slave Mode 1 512 CC70 Auto Mode 0 99 CP70 Pulse Mode 0 99 DE70 Gradually Mode 0 99 R255 R Dimmer 0 255 G255 G Dimmer 0 255 B255 B Dimmer 0 255 W255 W Dimmer 0 255 ST00 Strobe Speed slow fast 0 16 ...

Page 11: ...the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave Connections and Settings 1 Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR data cables to link your units together Remember that the Male XLR connector is the input and the Female ...

Page 12: ...Dimensional Drawing FIRST PL067 FIRST PL067User Manual Page 10 NOT TO SCALE unit mm ...

Page 13: ...solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Due to fog residue smoke and dust cleaning the internal and external optical lenses must be car ried out ...

Page 14: ... prior written notice Model FIRST PL067 Voltage LEDs IP Rating Working Position Power Draw Power Linking Weight Dimensions Colors DMX Channels Warranty 100V 240V 50 60Hz 14x 10W 4 in 1 CREE LED s IP65 Any safe working position 140W 20 Fixtures Max 120V 40 Fixtures Max 240V 4 2Kgs 230 x 165 x 300mm RGBW Color Mixing 4 DMX Modes 8 Channel Mode 2 Year https www piu39av com pluslite lighting ...

Reviews: