PIU39 PLUSlite First-PL067 User Instructions Download Page 2

FIRST-PL067   User Manual Page 2

 

 

 

  

FIRST-PL067

 

Synopsis 

Unpacking: 

Thank  you  for  purchasing  the  FIRST  PL067  by  PLUSLITE  Products.  Every  FIRST 

PL067  has  been  thoroughly  tested  and  has  been  shipped  in  perfect  operating  condition.  Carefully 
check the ship- ping carton for damage that may have occurred during shipping. If the carton appears 
to be damaged, carefully inspect your fixture for any damage and be sure all accessories necessary to 
operate the unit has arrived intact. In the case damage has been found or parts are missing, please 
contact our toll free  customer support number for further instructions. Do not return this unit to your 
dealer without first contacting customer support.

 

Introduction: 

The FIRST PL067 is a DMX intelligent, IP rated LED par fixture. This fixture can be used 

in a stand alone mode or connected in a Master/Slave configuration. This par has multiple operating 
modes:  RGBW  dimmer  mode,  Static  Color  mode,  Auto  Run  mode,  Color  Macro  mode,  and  DMX 
control. 

This product is intended to be used by professionally trained personnel only and is not 

suitable for private use.

 

These  instructions  contain  important  safety  information  regarding  the  use  and  maintenance  of  this 
unit. Please keep this manual with the unit, for future reference.

 

Caution! 

There  are  no  user  serviceable  parts  inside  this  unit.  Do  not  attempt  any  repairs  yourself, 

doing  so  will  void  your  manufactures  warranty.  In  the  unlikely  event  your  unit  may  require  service 
please contact Più39.

 

PLEASE recycle the shipping carton when ever possible. 

 

 

 

Multi Colors Dimmer

 

 

Multi Operating Modes

 

 

Linear Dimming 0-100%

 

 

DMX-512 protocol

 

 

IP65 Locking 3-Pin XLR Connections In/Out

 

 

Two DMX Modes: 4 Channel Mode, 8 Channel Mode

 

 

Multiple Unit Power Linking

 

 

Included:

 

1 x IP65 Locking Power Cable

   

 

 

Summary of Contents for PLUSlite First-PL067

Page 1: ...First PL067 IP65 ParLed User Instructions https www piu39av com pluslite lighting ...

Page 2: ...n be used in a stand alone mode or connected in a Master Slave configuration This par has multiple operating modes RGBW dimmer mode Static Color mode Auto Run mode Color Macro mode and DMX control This product is intended to be used by professionally trained personnel only and is not suitable for private use These instructions contain important safety information regarding the use and maintenance ...

Page 3: ...perating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit s weight Also always use a safety cable that can hold 12 times the weight of the unit when installing the fixture The equipment must be installed by a professional and it must be installed in a place where it is out of the reach of people s grasp Ensure ALL c...

Page 4: ...ufacturer See page 24 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the fixture C The fixtu...

Page 5: ...ion indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and low pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note although this fixture is IP rated the fixture is NOT suitable for marine and or coastal environment installati...

Page 6: ...FIRST PL067 Layout PL067User Manual Page 4 IP65 Locking Power Connection In Out IP65 Locking Singal 3P Connector In Out LED Display Mode button Up button Down button Enter button ...

Page 7: ...ing at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The PL067 can be controlled via DMX 512 protocol The PL067 has 2 DMX channel modes The DMX address is set on the back panel of the PL067 Your...

Page 8: ...rom which thefixture startsto listen to thedigitalcontrolsignalsent outfrom the DMXcontroller The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display on the fixture You can set the same starting address for all fixtures or a group of fixtures or set different addresses for each individual fixture Setting all fixtures to the same DMX...

Page 9: ...r 0 100 0 255 8CH Describe Parameter CH1 Main Dimming 0 255 CH2 Strobe Speed 0 255 CH3 Dimming Mode Macro Color 1 Macro Color 2 Macro Color 3 Macro Color 14 Macro Color 15 Ayto Mode Pluse Mode Gradual Mode 0 10 11 20 21 30 31 40 141 150 151 160 161 190 191 220 221 225 CH4 Mode Speed 0 255 CH5 R Dimming 0 255 CH6 G Dimming 0 255 CH7 B Dimming 0 255 CH8 W Dimming 0 255 ...

Page 10: ...Describe Parameter D001 DMX 4CH Mode Master Slave Mode 1 512 A001 DMX 8CH Mode Master Slave Mode 1 512 CC70 Auto Mode 0 99 CP70 Pulse Mode 0 99 DE70 Gradually Mode 0 99 R255 R Dimmer 0 255 G255 G Dimmer 0 255 B255 B Dimmer 0 255 W255 W Dimmer 0 255 ST00 Strobe Speed slow fast 0 16 ...

Page 11: ...the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave Connections and Settings 1 Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR data cables to link your units together Remember that the Male XLR connector is the input and the Female ...

Page 12: ...Dimensional Drawing FIRST PL067 FIRST PL067User Manual Page 10 NOT TO SCALE unit mm ...

Page 13: ...solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Due to fog residue smoke and dust cleaning the internal and external optical lenses must be car ried out ...

Page 14: ... prior written notice Model FIRST PL067 Voltage LEDs IP Rating Working Position Power Draw Power Linking Weight Dimensions Colors DMX Channels Warranty 100V 240V 50 60Hz 14x 10W 4 in 1 CREE LED s IP65 Any safe working position 140W 20 Fixtures Max 120V 40 Fixtures Max 240V 4 2Kgs 230 x 165 x 300mm RGBW Color Mixing 4 DMX Modes 8 Channel Mode 2 Year https www piu39av com pluslite lighting ...