SDT333A DI380/DI425/SI3300/SI3500 Service Manual
7-3
7 • Service Menu & Troubleshooting
7.2.10 calibrate Q station
This is to set the position of the envelope stops. Initially set by the factory.
•
DI425/SI3500 = 130
•
DI380/SI3300 = 130
7.2.11 set Fold Plate Offsets
This is to offset the fold panel lengths to match the lengths programmed in by the customer. Initially
set by the factory.
•
Fold Plate 1
•
Fold Plate 2
7.2.12 set env stop count
This sets the timing of the inset drive solenoid to energise, which determines how hard the envelope
drives into the envelope stops. Initially set by the factory.
•
DI425/SI3500 = 15
•
DI380/SI3300 = 15
7.2.13 set serial Number
This is to set the serial number of the machine. EIU Use only.
7.2.14 View software Revision
This displays the current level of software.
7.2.15 select OMR Basic Mode
When code is entered the following functions will appear.
•
OMR/Acc Mode is
off
•
OMR/Acc Mode is
on
•
OMR/Acc Mode is
Acc only
7.2.16 select OMR enhanced
Enter Code to turn on. The Extra Functions will appear in Job set up (71).
Enter code 350350 to enable enhanced OMR functionality.
7.2.17 Basic Wetter constant
This sets the timing of the sealer brush to contact the envelope flap. Lower numbers contact the
envelope sealer earlier. Higher numbers make the sealer brush contact the envelope later.
•
DI425/SI3500 = 25
•
DI380/SI3300 = 110
Summary of Contents for DI380 Series
Page 32: ...3 18 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 3 Theory of Operation ...
Page 50: ...4 18 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 4 Removal Replacement ...
Page 66: ...5 16 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 5 Adjustments ...
Page 102: ...7 22 SDT333A DI380 DI425 SI3300 SI3500 Service Manual 7 Service Menu Troubleshooting ...
Page 122: ......