Filter Data Function (FDF) Data Logging:
The FDF feature allows managers to track oil usage and filtering events by operators. These features
can be incorporated into an overall oil management strategy to extend oil life through an enforced
filtering regimen in combination with CFL.
3.1 Data
Logging:
The FDF will store data for three batches of oil – the current batch, and the two past batches. The
use of the Dispose function saves the current batch data to history and resets data logging values
for the new oil batch.
For a batch of oil, the FDF logs the following data:
Number of Filter Operations
Number of Oil Hours
Management of oil through methods other than qualifying Filter Events and Disposes are not
logged.
3.2 Data
Viewing:
With no cook timers running, displays will show one of the following displays:
,
, or
.
Press the
key. The left display will show
. The right display will be
blank.
Enter password
FDF Password
9
4
9
5
using the product keys as a numeric keypad for
entry.
The display will show collected data on the current batch of oil (for the Left vat if split), as indicated
by the number “1” in the first digit of the right display.
o
This is the number of filter events completed (nnnnn) for the current batch of oil. Press
product key [P] to continue.
o
This is the number of hours (nnnnn) oil has been at temperature for the current batch
of oil. Press product key [P] to continue.