7 Other
Displays:
Open probe detection is standard on all Pitco
controls. If probe is detected open, normal
heating and cooking activities are suspended.
This display warns operators that the vat
temperature has exceeded set temperature by
+40°F (+22°C), or an absolute maximum of
410°F (210°C). The alarm will also sound. This
display does not show the status of the
mechanical high limit switch.
This message indicates that the drain valve has
been opened, the vat is assumed to be empty by
the controller. Normal heat control activities are
suspended. Display will show an alternating
message [DRAINING] [TURN OFF]. To restore
to normal operation, close the drain value.
Display will show [TURN OFF] [TURN OFF].
This message indicates that the heating system
failed to respond. Typically, the high
temperature limit switch has tripped and is in
need of resetting. In the case on gas fired
appliances, this message will display if the pilot
fails to light or is detected marginal by the
ignition module.
This message indicates a shorted probe. If probe
is detected as a short circuit, normal heating and
cooking activities are suspended.
This message indicates that the operator has
exceeded the maximum number of deferrals and
is currently locked out of cooking until a filter
operation has completed and normal operations
can be resumed.
This message indicates that food has been
detected in the Vat due to a rapid decrease in
temperature and is always accompanied by the
above message. Any heat being applied to vat
is immediately terminated a buzzer will also
sound to alert operator of this state.
This message indicates that an error has
occurred with the computer. A factory reset,
answer YES, is required for continue use. This
message follows a Checksum Error.