background image

11

L20-249 rev 

2

 (05/1

3

)

1

2

3

4

5

6

7

8

9

Summary of Contents for SG18-2WKS-FD

Page 1: ...r Gas Fryers ALL OPTIONS Covering Models SG18WKS SGF18WKS SG18 2WKS FD Pitco Frialator Inc P O Box 501 Jct I 89 I 93 Concord NH 03302 0501 509 Route 3A Bow NH 03304 2 05 13 603 225 6684 FAX 603 225 8497 www pitco com FRANCAIS ENGLISH SGF18WKS SG18WKS ...

Page 2: ...s leaks WARNING DO NOT sit or stand on this appliance The appliance s front panel tank splash back tank cover work shelf drain board is not a step Serious injury could result from slipping falling or contact with hot liquids WARNING NEVER use the appliance as a step for cleaning or accessing the ventilation hood Serious injury could result from slips trips or from contacting hot liquids WARNING Th...

Page 3: ...otliquids Leveling Whenyou receive your fryer it is completely assembled The fryer will need to be leveled once it is in place Leveling thefryer is done with a large pair of water pump pliers The casters provide the necessary height to meet sanitation requirementsand assure adequate air supply to the burner a Adjust the height and level the fryer by adjusting the leveling devices on the caster wit...

Page 4: ...plied ELECTRICAL CONNECTION Theelectrical service used by the fryer must comply with local codes If there are no local codes that apply refer to theNational Electrical Code NEC ANSI NFPA 70 to install the service In Canada refer to CSA Standard C22 1 andlocal codes Wiring diagrams are provided inside the fryer control box The power requirements for the fryer are shownbelow NorthAmerica Internation...

Page 5: ...system should be designed toallow for easy cleaning Frequent cleaning of the ventilation system and the fryer will reduce the chances of fire Table 1 2provides a list of reference documents that provide guidance on ventilation and fire safety systems This table is notnecessarily complete Additional information can be obtained from CSA International 8501 East Pleasant Valley Road Cleveland OH 44131...

Page 6: ...UDONOTTURNFRYEROFFWHENWATERBEGINSTOBOIL WATER WILL BOIL OVER AND DAMAGE THE FRYER Note donotleavethefryerunattendedduringthisoperation NOTE Donotleavethefryerunattendedduringcleaning Neverletthe waterlevelgobelowthe MinLevel markonthebackofthetank c While wearing protective gloves use the fryer cleaning brush to scrub the inside of the fryer to remove protective coating d When cleaning is complete...

Page 7: ...e fryer Shut down the fryer by STANDBY Turnthe power switch to the OFF position The cooker is now in Standbyand can remain this way for only brief periods of time NEVER leave the cooker in standby overnight COMPLETE Tocompletelyshut down the cooker push and turn the gas valveto the OFF position The fryer is now completely shut down and can be cleaned and filtered ComputerOperation Referto the FAST...

Page 8: ...f the tank as the oil drains e Whenthe tank is empty close the blue handled drain valve Push Red oil flow selector valve handle in f Ensurethat pump circuit breaker switch is in ON position Turn power switch to the PUMP position Filter shorteningaccording to KFC Standards Library specifications When finished add more shortening to the tank ifshortening level does not reach the fill mark the fryer ...

Page 9: ...er rack and slide the filter rack out of the pickup assembly d Removefilter rack from the filter envelope e Allof the filter pick up assembly parts can be washed in a dish washer or a pot sink Flush out the suction tube assemblywith hot water After cleaning it is very important to thoroughly dry the parts before reassembling Water and oil do not mix Water in hot oil will cause the oil to splatter ...

Page 10: ...into polish position by pulling red selector valve handle out d Opendrain valve by pulling blue drain valve handle down e Pushpower switch to the PUMP position and start polish timer f Whentimer ends polish procedure is complete refer to KFC Standards Library for next procedure WARNING Thepowersupplymustbedisconnectedbeforeservicingorcleaningthe appliance FRYERCLEANING Dailyandweeklycleaning Yourf...

Page 11: ...9 L20 249rev 2 05 13 ...

Page 12: ...utomatically ignites gas burners 4 Manual Gas shut off valve Turns OFF gas to fryer 5 Heat Light Lights when computer is calling for heat 6 ON OFF PUMP switch Turns fryer heater ON OFF or turns pump ON OFF 7 Hi Limit Reset button Allows Hi limit to be reset if oil gets too hot 8 Filter pump breaker Trips when pump is overloaded OFF then ON resets 9 Oil flow selector Red Selects between oil polish ...

Page 13: ...11 L20 249rev 2 05 13 1 2 3 4 5 6 7 8 9 ...

Page 14: ...ish swivel assembly Directs oil to filter swings out for easy oil disposal 4 Filter pan Holds oil during filtering and oil polishing 5 Oil Flow Selector Selects between oil polish and frypot refill 6 Filter pick up strainer Prevents cracklings from getting in the pump 7 Filter rack Supports the filter paper during filtering polishing 8 Filter pick up assembly Holds paper folded and connects to the...

Page 15: ...13 L20 249rev 2 05 13 1 2 3 4 5 6 7 8 ...

Page 16: ...www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area or contact Pitco at the number listed to the left MAILING ADDRESS P O BOX 501 CONCORD NH 03302 0501 SHIPPING ADDRESS 10 FERRY STREET CONCORD NH 03301 L20 249 R2 06 13 ...

Reviews: