Pitco PE14D Upgrade Instructions Download Page 2

High Temperature Limit Upgrade Instructions Model PE14D

 

L80-039 Rev. 1 

Page 2 of 3 

11/6/2012 

 

A) Element Shield Cover 

B) Screw 

Diagram A 

 

 

A)  High Temperature Limit 
B)  High Temperature Limit Wiring Connector 

Diagram B 

 

A) High Temperature Limit 

B) Wiring 

C) Bracket 

D) 6-32 Screws 

E) Element Shield Cover 

F) Self Tapping Screws 

Diagram C 

Tools Required 

 

 

Flat blade screwdriver 

 

Phillips screwdriver 

 

11/16” Combination wrench 

 

9/16” Combination wrench 

 

3/8” Combination wrench 

 

5/16” Socket and a ratchet 

 

5/16” Combination wrench 

 

Drill with 7/32” & 5/16” drill bits* 

*may not be required for all upgrades

 
 
 
 
 
 

High Temperature Limit Removal 

 
1.  Ensure that the power is disconnected and that the tank is 

drained. 

 
2.  Open the door to the appliance to access the element 

shield. 

 
3.  Remove the one screw securing the element shield cover.  

Keep the screw in a safe place since it will be required 
later.  (See Diagram A) 

 
4.  Slide the element shield cover down and remove. 

(See Diagram A) 

 
5.  Disconnect the wire harness from the high temperature 

limit.  (See Diagram B) 

 
6.  Remove the high temperature limit from the appliance.  

(See Diagram B) 

 
 

Element Shield Cover Subassembly 

 
1.  Attach high temperature limit wiring to the 

new

 high temperature limit.  (See Diagram C) 

 
2.  Fold over the flaps on the high temperature limit to cover the wiring connections.  (See Diagram C) 
 
3.  Attach the high temperature limit to the bracket using two 6-32 screws.  (See Diagram C) 
 
4.  Attach the high temperature limit subassembly to the 

new

 element shield cover using two 10-24 self tapping 

screws.  (See Diagram C) 

WARNING 

The power supply must be disconnected 
before servicing this appliance

WARNING 

Drain the appliance before performing 
the following procedure

Reviews: