I8 Water Cooker Computer Service
Pitco P/N PP11375
14
L22-303 Rev 0 (01/07)
5.2 High Temperature Alarm:
[
HIGH TMP
]. This alarm will occur if the vat temperature exceeds the set temperature
value by 35
°
F. If a high vat temperature alarm occurs, all heating and cooking functions
are suspended.
5.3 Drain Valve Alarm:
[
DRAINING
] and [
TURN OFF
] (alternating). This alarm message will appear on the
control display if the drain valve on the appliance is opened while the control is ON. All
heating and cooking functions are suspended if this alarm occurs.
5.4 Heat Failure Alarm:
[
HEAT
] and [
FAILURE
] (alternating). This alarm will occur if the control does not sense
a pilot flame or if the high limit switch has tripped and needs resetting. All heating and
cooking functions are suspended if this alarm occurs.
5.5 System Failure Alarm:
[
SYSTEM
]. This alarm will occur if the control detects a shorted temperature probe. All
heating and cooking functions are suspended if this alarm occurs.