ENGLISH
27
Frequent Flare-Ups
Cooking Temperature
Attempt cooking at a lower temperature. Grease does have a flash point. Keep the temperature under
176°C / 350°F when cooking highly greasy food.
Grease Build-Up On
Cooking Components
Follow
Care and Maintenance
instructions.
ErP Error Code
Grill Probe Not
Connected
Disconnect and reconnect the Grill Probe.
Faulty Grill Probe
Grill Probe needs to be replaced. Contact Customer Care for a replacement part.
ErH Error Code
The Unit Has
Overheated, Possibly
Due To Grease Fire Or
Excess Fuel
Press and hold the Power Button for 3 seconds to turn the unit off, and allow grill to cool. Follow
Care and Maintenance
instructions. After maintenance, remove pellets, and confirm positioning of
all component parts. Once cooled, press the Power Button to turn the unit on, then select desired
temperature. If error code still displayed, contact Customer Care.
ErL Error Code
Grill fails to perform
start-up cycle
Check proper positioning of cooking components. Check hopper for sufficient fuel or if there is an
obstruction in the feed system. Remove pellets and follow
Care and Maintenance
instructions. Check
grill probe. Confirm if actual temperature is correct and accurate. Follow
Care and Maintenance
instructions if dirty. Check ignitor positioning and that it is heating up properly. In extreme cold, the
grill may require a second start. Turn grill off, wait, then turn on again. Check fan. Ensure it is working
properly. Follow
Care and Maintenance
instructions if dirty.
Grill will not stay lit
Err Error Code with
PELLET Error Code
Blinking
Lack Of Fuel, Poor Fuel
Quality, Obstruction In
Feed System, Jammed
Auger
Check hopper to check that fuel level is sufficient and replenish if low. Should the quality of wood
pellets be poor, or the length of the pellets too long, this may cause an obstruction in the feed system.
Remove pellets and follow
Care and Maintenance
instructions.
Err Error Code with
IGNITOR Error Code
Blinking
Ignitor is not working
properly, not making a
connection
Remove cooking components from the Main Barrel. Press the Power Button to turn the unit on
and inspect the igniter. Visually confirm that the igniter is working by placing your hand above the
burn grate and feeling for heat. Visually confirm that the igniter is aligned with the hole in the burn
grate, and open to light the pellets. If not operating properly, call Customer Care for assistance or a
replacement part.
Ignitor failure
Igniter needs to be replaced. Contact Customer Care for replacement part.
Err Error Code with
AUGER Error Code
Blinking
Auger not primed
Before the unit is used for the first time or anytime the hopper is completely emptied out, the auger
must be primed to allow pellets to fill the feed system If not primed, the igniter will timeout before
the pellets ignite. Follow
Hopper Priming Procedure
.
Auger motor is jammed,
not making connection
Remove cooking components from the Main Barrel. Press the Power Button to turn the unit on and
inspect the auger feed system. Visually confirm that the auger is dropping pellets into the burn pot. If
not operating properly, call Customer Care for assistance or a replacement part.
Err Error Code with
FAN Error Code
Blinking
Fan is not working
properly, not making a
connection
Check fan. Ensure it is working properly and air intake is not blocked. Remove hopper access panel
(see
Electric Wire Diagram
for diagram), and check for any damage to the fan wires. Follow
Care and
Maintenance
instructions if fan blades are dirty.