Type
Low vacuum, 90L
Low vacuum, 120L
Configuration
RPV063-90T200
RPV064-120V200
Number of rotor
Triple (3)
Quad (4)
Rotor layout
Parallel layout
Parallel layout
Pumping speed (L/min)
50
㎐
90
120
60
㎐
108
144
Final vacuum (Pa abs)
50
㎐
≦
3,500
60
㎐
≦
3,000
Final vacuum (kPa G)
50
㎐
≦
-97.8
60
㎐
≦
-98.3
Max. vacuum pressure
Atmospheric pressure
Ambient temp. (indoor) (ºC)
5
~
40
Ambient humidity (indoor)
Maximum 85%RH (no dew condensation)
Gas (inhaled gas)
No corrosive / exposable gas
Vibration of installation site
Max 4.9m/s
2
(10~60Hz)
Altitude of installation site
1000meter or less above sea level
Install orientation
Horizontal installation of the motor axis (shaft)
M
ot
or
Output (W)
90
120
Type
3 phase motor built-in thermal protector,
Heat proof class 130(B)
Voltage (V)(*3)
200
/
220
/
230
200
Rated current (A)
50
㎐
0.62
/
ー
/
ー
0.74
60
㎐
0.56
/
0.56
/
0.58
0.68
Rated rotation speed
(min¯¹)
50
㎐
1,350
/
ー
/
ー
1,350
60
㎐
1,625
/
1,650
/
1,675
1,600
Striking current (A)
50
㎐
2.0
/
ー
/
ー
2.6
60
㎐
1.8
/
2.0
/
2.1
2.4
Operation noise
(dB(A))(*1)
50
㎐
≦
58
60
㎐
≦
63
Vacuum port size
G1/ 2
Exhaust port size
G3 / 8
Dimensions (width x depth x height) (mm)
125
×
340.6
×
181
125
×
397.6
×
181
Weight (kg)
9.0
(*2)
10.5 (*2)
Cooling system
Forced air cooling
*1) Operating noise is the maximum measured value in load variation, which excludes the suction noise and exhaust noise by centralized piping,
and is not a guaranteed value.
*2) Weight includes attached 2 blank plugs.
*3) Allowable intermittent power supply voltage fluctuation range is ±10% of the specified voltage; allowable sustained supply voltage fluctuation
range is ± 3% of the specified voltage.