7
0
101.33
-101.33
Absolute pressure basis
[
kPa abs
]
Absolute
pressure
Atmospheric (gauge)
pressure basis
[
kPa
]
standard atmospheric pressure
0
-10
10
20
30
40
50
60
70
80
90 100
-20
-30
-40
-50
-60
-70
-80
-90
-100
RPV062, 063, 064
RPV062, 063, 064
RPV06A
RPV06A
http://www.
pisco.co.jp/
Type
Medium vacuum, 30L
Configuration
RPV06A-40T200
RPV06A-40S100(S100SW
(
*2
)
)
RPV06A-40S110
Number of rotor
Twin (2)
Rotor layout
In-line layout
Pumping speed (L/min)
50
㎐
30
60
㎐
36
Final vacuum (Pa abs)
50
㎐
≦
350
60
㎐
≦
300
Final vacuum (kPa G)
50
㎐
≦
-100.95
60
㎐
≦
-101.0
Max. vacuum pressure
Atmospheric pressure
Ambient temp. (indoor) (ºC)
5
~
40
Ambient humidity (indoor)
Maximum 85%RH (no dew condensation)
Gas (inhaled gas)
No corrosive / exposable gas
Vibration of installation site
Max 4.9m/s
2
(10~60Hz)
Altitude of installation site
1000meter or less above sea level
Install orientation
Horizontal installation of the motor axis
M
ot
or
Output (W)
40
Type
3 phase motor built-in thermal
protector, Heat proof class 130(B)
Capacitor-start single phase induction motor built-in thermal
protector, Heat proof class 130(B)
Voltage (V)(*3)
200
/
220
/
230
100
110/115
Rated current (A)
50
㎐
0.31
/
ー
/
ー
0.83
ー
60
㎐
0.29
/
0.28
/
0.29
0.7
0.67/0.68
Rated rotation speed
(min¯¹)
50
㎐
1,350 /
ー
/
ー
1,250
ー
60
㎐
1,625 / 1,675 / 1,675
1,600
1,625/1,625
Striking current (A)
50
㎐
0.9
/
ー
/
ー
1.7
ー
60
㎐
0.82
/
0.91
/
0.96
1.5
1.7/1.8
Operation noise
(dB(A))(*1)
50
㎐
≦
58
ー
60
㎐
≦
63
Vacuum port size
G3 / 8
Exhaust port size
G1/ 4
Dimensions (width x depth x height) (mm)
125
×
284.6
×
166.5
(
S100SW
(
*2
):
125
×
289.6
×
180.8
)
Weight (kg)
7.2
(
S100SW
(
*2
):
7.6
(* including attachments))
Cooling system
Forced air cooling
*1) Operating noise is the maximum measured value in load variation, which excludes the suction noise and exhaust noise by centralized piping,
and is not a guaranteed value.
*2) A model with a built-in power switch. Not corresponding to CE marking.
*3) Allowable intermittent power supply voltage fluctuation range is ±10% of the specified voltage; allowable sustained supply voltage fluctuation
range is
±
3% of the specified voltage.
Specification(Midium Vacuum)
About vacuum pressure indication
■
Absolute pressure (kPa abs or Pa abs) and gauge pressure (kPa G) are used in Pisco's vacuum pump
catalogue. Please be careful not to make a mistake in a unit when selecting a pump.
IN
OUT
Summary of Contents for RPV06 Series
Page 28: ...28 Rotary Vacuum Pump Memo ...