Piranha Ironworker P65
23
Troubleshooting
Many of these problems can be solved by following a step-by-step procedure for isolating
the issue. Take notes on the steps tried, and the outcomes. This way if you are not able
to fix the issue, you can pass on what has been done and tried already to the Piranha
technician.
Potential Problems and Solutions
P1 - Machine Will Not Start
1. Check that selector switch is turned to the control box you are starting the
machine from.
2. Check fuses at disconnect.
3. Check voltage to motor starter.
4. Transformer control voltage (Output - 120 V). If not, check:
A. Transformer fuse. If blown, inspect circuit for a ground short.
B.
Incoming voltage to input side of transformer is correct and the jumper bars
are in the correct location. Reference page
C.
All wire and fuse holder connections are tight.
D. Possible faulty transformer.
5. Control circuit from transformer to front and rear control boxes to motor starter
coil. (Reference Wiring Diagram page