10
4.
When I insert a new battery in the dial I hear a low pitched tone from the
Base Unit.
Battery voltage low
A single low pitched beep signifies a low battery. This is accompanied by
slow flashing of the light on the dial. Replace battery with a new one.
5.
After a blackout or after plugging in the Base Unit the alert begins to
sound immediately.
One of the burners was ON prior to the power being lost. To help provide
maximum protection, the base unit will remember if a burner was on prior to
losing power. If a burner was on then it will alert you immediately once power is
restored to remind you that something was cooking and the burner may still be
on.
The alarm can be stopped by touching each of the dials one at a time. This
will renew the link to the base unit.
If the alarm continues to sound then the base unit may need to be reset. To
reset touch and hold the learn button on the base unit until you hear 3
beeps. This will erase all settings in memory and disable the RangeMinder.
In this case you must put the base unit back into learning mode and touch
each dial to renew the link to the base. Ensure the base beeps once for
each dial. If this step is not performed the RangeMinder will remain
disabled.
6.
After cleaning my stove/range the RangeMinder began to beep or did not
operate properly.
During the calibration process each dial is setup to work with the particular
sensor ring below it. Moving a dial to a different burner may cause the dial to
not operate properly.
Move the dial back to the position used during the calibration
OR
Remove the battery and perform the calibration procedure again for the new
position.